Tank gauging
Analogue Transmitter AT1
For remote monitoring of a tank
The AT1 transmitter is designed to attach to the LT5 level gauge. Main functions are 4 to 20mA analogue output and alarm contact output.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Quick selection
Individual configuration
-
Benefits
Transmission of the tank level by analogue signals
Max. 6 alarm contact outputs
Easy maintenance due to simple mechanism
-
Field of application
Ambient temperature: -20 to +60°C (-4 to +140°F)
Documents / Manuals / Software
-
Analog Transmitter AT1000 AT1 - Technical Information
AT1 analog transmitter is designed to be installed to the LT, and LTC
series float level gauge. One of the main functions of the transmitter
is to transmit the level gauge’s signals into voltage, electric current,
and resistance output signals.
Because this model has a variety of output signal types, it has an
extensive connection compatibility with various level setting devices.
In addition, the alarm and adjustment contact signals are equipped with
up to six points, enabling the operator to direct the valves andpumps
with this transmitter alone.Technical Information (TI) -
Analog Transmitter AT1000 AT1 - Operating Instructions
AT1 analog transmitter is designed to be installed onto LT and LTC
series level gauging systems. The device transmits the level information
into electric current, voltage, and resistance signals. It can also be
equipped with a maximum of six alarm contact signals.
In addition to transmitting the level, contact signals can be received
by this transmitter alone, enabling easy control ofthevalve and pump.Operating Instruction (BA) -
Operating Instractions AT1
Operating Instractions AT1000
Tank Gauging
Operating Instruction (BA) -
Tank Gauging
Система коммерческого и оперативного учета продуктов
в резервуарных парках.Competence Brochure (CP)07/15Russian -
AT1- Picture
Tank gauging
Picture10/07Language neutral -
Sakura
Product Code: AT1-
Region/Country: Japan
Approval Agency: TIISExplosion ProtectionJapanese -
Sakura
Product Code: AT1-
Region/Country: Japan
Approval Agency: TIISExplosion ProtectionJapanese -
Sakura
Product Code: AT1-
Region/Country: Japan
Approval Agency: TIISExplosion ProtectionJapanese
Accessories / Spare parts
-
-
Nr 11 Order code 017880-5025
O-ring, Large terminal box, AT5 body,CR
Size: D120mm, d3.5mm. Material: CR. Part: terminal box, large. Usage: AT1/500, B3-11, DRM9700, DU/R, MPC2, TGM5, TMD1.
-
Nr 11 Order code 017880-5026
O-ring, terminal box, small, CR
Size: D100mm, d3mm. Material: CR (Chloroprene Rubber). Part: terminal box, small. Usage: AT1/AT500, DRM9700, DU, NRR261/NRR263, NMT539 Converter, TGM5.
-
Nr 11 Order code 017880-5027
O-ring, El-compartment, large
Size: D196mm, d7mm. Material: CR (Chloroprene Rubber). Part: main body cover, AT1/AT500, B3-11. Usage: AT1, AT500, B3-11.
-
Nr 11 Order code 017871-1231
O-ring, LT/transmitter coupling
Size: D60mm, d3.5m. Material: CR (Chloroprene Rubber). Part: LT-coupling. Usage: AT1/AT500, DU, DUR, TMD1.
-
-
-
Nr 21 Order code 017860-6323
Cover, terminal box
Short terminal box cover. Color: silver. Material: aluminium casting. Usage: AT1/AT500, DRM9700, MPC, balancer, TMD1.
-
Nr 21 Order code 017860-6326
Large-short cover, main body
Short main mody cover. Color: silver. Material: aluminium casting. Usage: AT1/AT500, B3-11.
-
Nr 21 Order code 017860-6324
Cover, terminal box, large
Large terminal box cover. Color: silver. Material: aluminium casting. Usage: AT1/AT500, DUR, MPC, TMD1, B3-11.
-
-
-
Nr 31 Order code 017871-1201
-
Nr 31 Order code 56004475
-
Nr 31 Order code 56004479
-
Nr 31 Order code 56004476
-
-
-
Nr 32 Order code 017871-1207
-
Nr 32 Order code 56004478
-
-
-
Nr 33 Order code 017871-1202
Potentiometer, CPP45, LT, LTC2230/40
Type: CPP45-RK with R: 500 ohm. For LT series, LTC2230/LTC2240. Usage: AT1.
-
Nr 33 Order code 56004470
Potentiometer, CPP45, LTC2110
Type: CPP45-RK with R: 500 ohm. For LTC2110. Usage: AT1.
-
-
-
Nr 36 Order code 017871-1210
Main shaft assembly, AT1
-
-
-
Nr 37 Order code 017871-1211
-
Nr 37 Order code 017871-1212
-
-
-
Nr 45 Order code 017871-1220
-
-
-
Nr 75 Order code 70106501
Stud bolt M10x40L,spr.washer,washer,4set
For transmitter fitting. Usage: AT1.
-
Nr 75 Order code 017871-1233
Coupling, transmitter, LT11/LT12
ADC, with nut, M4, washer, O-ring. Stud,M10x37/17x10L,nut,M10, 4x washer. Usage: AT1, AT500.
-
Nr 75 Order code 017871-1232
Coupling, male,for gauge head, MP/HP
Gauge head side,male pin type,Alu plate without female coupling for transmitter with washer M4 SUS304,nut M4 SUS304. Usage: LT5, LT14/LT16, LT34/LT36.
-
-
-
Nr 38 Order code XPN0001-
Dial Plate AT1
-
-
-
Nr 40 Order code XPN0002-
Gear Panel Assembly AT1
-
-
-
Nr 42 Order code XPN0003-
Alarm Assembly AT1
-
-
Predecessor