Specs at a glance
-
Process temperature
-40°C ... 150°C
(-40°F ... 300°F) -
Process pressure absolute / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 360 psi) -
Min. density of medium
200 g/l
Field of application
Soliphant FTM20 is a point level switch for applications with fine-grained or coarse-grained, non-fluidized bulk solids. The various designs means the device has a wide range of applications. Certificates are also available for use in dust and hazardous areas.
Point level switch in compact design with stainless steel housing.
Process connections: Threads
Temperature: -40 to +150°C (-40 to +302°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
International explosion protection certificates, overfill prevention WHG, marine approvals
Benefits
Operational safety, reliability and universal applicability through use of the tuning fork measuring principle
Measurement is unaffected by conductivity, build-up, turbulence, flows or air bubbles
Simple and fast commissioning, no calibration required
No mechanically moved parts, free of maintenance
Safe function due to self-monitoring (active frequency monitoring of the fork)
Easy recurring function test via test magnet
Suitable for constricted space due to compact design
Videos
-
Vibronic measuring principle
Fundamental selection
-
Simple products
- Easy to select, install and operate
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
Measuring principle
Vibration Solids
-
Characteristic / Application
Point level switch for fine grained solids
Single rod
Universal
No calibration required
Not affected by build-up or external vibration
Robust
Switch value visible from outside
Compact -
Specialities
Grain size <= 25 mm (< 0.98 in)
-
Supply / Communication
10 - 45V DC
19 - 253 VAC relay
DC PNP 10 - 45 V -
Ambient temperature
-40°C ... 70°C
(-40 °F ... 160 °F) -
Process temperature
-40°C ... 150°C
(-40°F ... 300°F) -
Process pressure absolute / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 360 psi) -
Min. density of medium
200 g/l
-
Main wetted parts
316L
-
Process connection
Thread
R 1"
R 1 1/2"
1 1/4" NPT
1 1/2" NPT -
Sensor length
225 mm (9")
-
Communication
DPDT relay
DC PNP max 350mA -
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, INMETRO, EAC
-
Application limits
Density: < 200 g/l
Grain size: > 25 mm (1")
Not for fluidised media
Configure to download the CAD drawings of this product
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories