Try searching by key words, order- or product code or serial number e.g. “CM442” or “Technical information”
Enter at least 2 characters to start the search.
Memocheck Sim CYP03D is the flexible service and qualification tool for all applications.

Digital service and qualification tool
Memocheck Sim CYP03D

All-round checker for Memosens measuring points in all industries

CYP03D
Please Wait (spinning wheel)
Loading price
Prices temporarily unavailable
Price on request
activating price
price: provide information
from CHF ??.-
Filter Measuring / Application task
Measuring / Application task

Configure to download the CAD drawings of this product

  • Measuring principle

    Potentiometric

  • Application

    Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
    Multiparameter, main- and secondary values

  • Installation

    Temporary connection via Memosens cable with inductive coupling

  • Measurement range

    Ranges like the simulated sensors

  • Dimension

    Handheld:
    94 x 236 x 40 mm
    3.7 x 9.29 x 1.57 inch

  • Process temperature

    Ambient temperature: –20 to 50 °C (–4 to 120 °F)

  • Ex certification

    ATEX, IECEx, CSA

  • Connection

    Battery powered

  • Ingress protection

    IP65

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
    Multiparameter, main- and secondary values

  • Installation

    Temporary connection via Memosens cable with inductive coupling

  • Measurement range

    Ranges like the simulated sensors

  • Dimension

    Handheld:
    94 x 236 x 25 to 40 mm
    3.7 x 9.29 x 0.98 to 1.57 inch

  • Process temperature

    Ambient temperature: –20 to 50 °C (–4 to 120 °F)

  • Ex certification

    ATEX, IECEx, CSA

  • Connection

    Battery powered

  • Ingress protection

    IP65

  • Measuring principle

    Conductive

  • Application

    Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
    Multiparameter, main- and secondary values

  • Installation

    Temporary connection via Memosens cable with inductive coupling

  • Measurement range

    Ranges like the simulated sensors

  • Dimension

    Handheld:
    94 x 236 x 25 to 40 mm
    3.7 x 9.29 x 0.98 to 1.57 inch

  • Process temperature

    Umgebungstemperatur: –20 to 50 °C (–4 to 120 °F)

  • Ex certification

    ATEX, IECEx, CSA

  • Connection

    Battery powered

  • Ingress protection

    IP65

  • Measuring principle

    Amperometric oxygen measurement

  • Application

    Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
    Multiparameter, main- and secondary values

  • Installation

    Temporary connection via Memosens cable with inductive coupling

  • Measurement range

    Ranges like the simulated sensors

  • Dimension

    Handheld:
    94 x 236 x 25 to 40 mm
    3.7 x 9.29 x 0.98 to 1.57 inch

  • Process temperature

    Ambient temperature: –20 to 50 °C (–4 to 120 °F)

  • Ex certification

    ATEX: Ex ia, zone 0

  • Connection

    Battery powered

  • Ingress protection

    IP65

  • Measuring principle

    Free chlorine

  • Application

    Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol
    Multiparameter, main- and secondary values

  • Measurement range

    Ranges like the simulated sensors

  • Dimension

    Handheld:
    94 x 236 x 25 to 40 mm
    3.7 x 9.29 x 0.98 to 1.57 inch

  • Process temperature

    Ambient temperature: –20 to 50 °C (–4 to 120 °F)

  • Connection

    Battery powered

  • Measuring principle

    Single beam scattered light

  • Application

    Simulation of freely configurable values for qualification of digital data transmission of analysis measuring points with Memosens protocol.
    Multiparameter, main- and secondary values

  • Installation

    Temporary connection via Memosens cable with inductive coupling.

  • Measurement range

    Ranges like the simulated sensors.

  • Dimension

    Handheld, 9,5 x 23,5 x 3,5 cm

  • Process temperature

    -20...55°C ambient temperature

  • Ex certification

    ATEX: Ex ia, zone 1

  • Connection

    Battery powered

  • Ingress protection

    IP65

Welcome to Endress+Hauser!

Please select your market / region