Specs at a glance
-
Sampling probe compatibility
Raman Rxn-10 probe
-
Wetted materials
Metal: C276 alloy as standard (316L stainless steel or Grade 2 titanium upon request)
Window: high-purity sapphire, proprietary compression fit non-brazed design
Field of application
The fixed focus design of the Raman immersion optic provides long-term measurement stability along with superior signal performance which is essential for transferable, high-performance Raman measurements. Compatible with the
Benefits
Ideal for quick measurements of liquids, slurries, and semi-solids in a laboratory setting
Superior signal performance
Available in 1/4” and 1/2” diameters
No user-adjustable parts
Wettable components resist corrosion in harsh environments (including acidic solutions)
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Accessory optics for the Rxn-10 probe Technical Information
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN 31/05/202303/08/2022Language:
English
Version:
31/05/2023
File size:
467.9 KB
File name:
TI01635CEN_0322.pdf
-
-
-
Technical Information (TI)
Rxn-10 Raman spectroscopic probe Technical Information
System design and specifications for the Raman Rxn-10 probe
EN 13/11/202431/05/202313/09/202208/09/2021Language:
English
Version:
13/11/2024
File size:
929.9 KB
File name:
TI01629CEN_0424.pdf
-
-
-
Operating Instruction (BA)
Accessory optics for the Rxn-10 probe Operating Instructions
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN 31/05/202303/08/202214/09/2021Language:
English
Version:
31/05/2023
File size:
1.8 MB
File name:
BA02171CEN_0322.pdf
-
-
-
Operating Instruction (BA)
Rxn-10 Raman spectroscopic probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probeEN 02/12/202431/05/202313/09/202208/09/2021Language:
English
Version:
02/12/2024
File size:
1.2 MB
File name:
BA02160CEN_0424.pdf
-
-
-
Short Instruction (KA)
Rxn-10 Raman spectroscopic probe Brief Operating Instructions
Quick start guide for the Raman Rxn-10 probe
EN 02/12/202431/05/202313/09/202208/09/2021Language:
English
Version:
02/12/2024
File size:
1.6 MB
File name:
KA01546CEN_0424.pdf
-
-
-
Short Instruction (KA)
Accessory optics for the Rxn-10 probe Brief Operating Instructions
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN 31/05/202303/08/202214/09/2021Language:
English
Version:
31/05/2023
File size:
1 MB
File name:
KA01551CEN_0322.pdf
-
-
-
PU (Publication)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Language:
English
Version:
19/04/2022
File size:
1.1 MB
File name:
PU01447CEN_0222.pdf
-
-
-
PU (Publication)
ライフサイエンス産業向けのラマンアプリケーションガイド -ライフサイエンスのための信頼できる組成分析
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。Language:
Japanese
Version:
02/08/2024
File size:
1.4 MB
File name:
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf
-
-
-
Competence Brochure (CP)
Raman spectroscopy food & beverage application guide - Trusted technology for composition analysis in a laboratory or process environment
A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).Language:
English
Version:
17/02/2022
File size:
859 KB
File name:
CP01489CEN_0122.pdf
-
-
-
Innovation (IN)
Raman spectrographic probes - Robust optical measurement of chemical composition
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.Language:
English
Version:
26/10/2021
File size:
4.9 MB
File name:
IN01225CEN_0121.pdf
-