This product is not available in this market.
Specs at a glance
-
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2
Field of application
The SS3000e analyzer is capable of measuring moisture (H2O) and carbon dioxide (CO2) in this cost-effective 2-channel system which incorporates two sensors into one analyzer. The sensors measure gas using patented tunable diode laser absorption spectroscopy (TDLAS) technology to determine the concentration of H2O and CO2 without coming into physical contact with the stream.
Natural gas quality measurements in production, storage, transportation, and distribution
Monitoring and controlling in the natural gas pipeline, processing plant, compressor station, gathering site, and distribution quality
Ideal for custody transfer measurements to ensure quality
Measurable ranges of up to 0-250 lb/mmscf (0-5275 ppm) H2O and up to 0-20% CO2 using two channels
Benefits
Accurate, real-time H2O and CO2 measurements using one analyzer
Virtually maintenance free and reliable in harsh environments
Fast and accurate with no wet-up or dry-down delays
No contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans
Low cost of ownership & no consumables, with analog and serial outputs for remote monitoring
Heated and unheated stainless steel sample conditioning enclosures with NEMA 4X system rating
CSA certified, Class 1, Division 2
Xpert selection
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
TDLAS
-
Product Headline
Dual channel gas analyzer for moisture (H2O) channels and carbon dioxide (CO2). The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream. Includes a heated enclosure for the sample conditioning system.
-
Channels
2
-
Analyte and Measurement ranges
H2O (Moisture): 0-100 to 0-5000 ppmv
CO2 (Carbon Dioxide): 0-5% to 0-50% -
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara or 700-1700 mbara (optional) -
Analyzer Wetted materials
316L Stainless Steel
FKM O-Rings
Glass -
Power supply
100-240 VAC, 50-60 HZ
OR
18-24 VDC - optional
1 Amp maximum @ 120 VAC, 1.6 Amps @ 24 VDC (unheated)
2 Amps maximum @ 120 VAC (heated) -
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C - standard, RS485 and Ethernet - optional
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 2, General Fault and Concentration/Assignable Alarm -
Housing materials
Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
Type 4X
-
Measuring principle
TDLAS
-
Product Headline
Dual channel gas analyzer for two moisture (H2O) channels. The sensor measures gas using Tunable Laser Diode Absorption Spectroscopy (TDLAS) to determine the concentration of the gas without coming into physical contact with the stream. Includes a heated enclosure for the sample conditioning system.
-
Channels
2
-
Analyte and Measurement ranges
H2O (Moisture): 0-100 to 0-5000 ppmv
-
Measured Variables
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature -
Ambient Temperature range
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F) -
Operating Pressure range
Inlet Pressure: 140-350 kPa (20-50 psig)
Sample Cell: 700-1400 mbara or 700-1700 mbara (optional) -
Analyzer Wetted materials
316L Stainless Steel
FKM O-Rings
Glass -
Power supply
100-240 VAC, 50-60 HZ
OR
18-24 VDC - optional
1 Amp maximum @ 120 VAC, 1.6 Amps @ 24 VDC (unheated)
2 Amps maximum @ 120 VAC (heated) -
Communication
Analog Output: Two 4-20mA Isolated, 1200 ohms @ 24 VDC max load
Serial: RS232C - standard, RS485 and Ethernet - optional
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 2, General Fault and Concentration/Assignable Alarm -
Housing materials
Electronics: 304 or 316L Stainless Steel
Sample System Enclosure: 304 or 316L Stainless Steel -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2 -
Degree of protection
Type 4X
Configure to download the CAD drawings of this product
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories