Proline Promass E 300
Coriolis flowmeter
Flowmeter with minimized total cost of ownership and a compact, easily accessible transmitter
The robust Promass E has a long-standing reputation as a cost-efficient solution accurately measuring liquids and gases in a wide range of standard applications in various industries. With its compact transmitter Promass E 300 offers high flexibility in terms of operation and system integration: access from one side, remote display, improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.
-
Lợi ích
Cost-effective – multi-purpose device; an alternative to conventional volumetric flowmeters
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in/outlet run needs
Full access to process...
-
Phạm vi ứng dụng
Measuring principle operates independently of physical fluid properties such as viscosity or density
Accurate measurement of liquids and gases for a wide range of standard applications.
Device properties
Compact dual-tube sensor
Medium temperature up...
Tài liệu / Tài liệu hướng dẫn / Phần mềm
-
Proline Promass E 300
Technical Information
Coriolis flowmeter
Flowmeter with minimized total cost of ownership and a compact, easily
accessible transmitterTechnical Information (TI) -
Proline Promass E 300
PROFIBUS DP
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 300
HART
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 300
PROFIBUS PA
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 300
EtherNet/IP
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 300
PROFINET
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 300
FOUNDATION Fieldbus
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass E 300
Modbus RS485
Operating Instructions
Coriolis flowmeter
Operating Instruction (BA) -
Proline Promass 300
PROFIBUS DP
Description of Device Parameters
Coriolis flowmeter
Proline Promass 300
PROFIBUS DPDevice Parameter (GP) -
Proline Promass 300
PROFIBUS PA
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
PROFINET
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
HART
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
Modbus RS485
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
FOUNDATION Fieldbus
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 300
EtherNet/IP
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline 300
PROFIBUS PA
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)11/18Tiếng Anh -
Proline Promass E
Brief Operating Instructions
Coriolis sensor
Short Instruction (KA)10/17Tiếng Anh -
Proline 300
FOUNDATION Fieldbus
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18Tiếng Anh -
Proline 300
EtherNet/IP
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18Tiếng Anh -
Proline 300
HART
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18Tiếng Anh -
Proline 300
Modbus RS485
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18Tiếng Anh -
Proline 300
PROFINET
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18Tiếng Anh -
Proline 300
HART
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16Tiếng Anh -
Proline 300
Modbus RS485
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16Tiếng Anh -
Proline 300
PROFIBUS DP
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)06/18Tiếng Anh -
Proline Promass
Brief Operating Instructions
Proline Promass
Part 1 of 2
Coriolis sensorShort Instruction (KA)04/17Tiếng Anh -
Flowmeter
Proline 300
Brief Operating Instructions
Transmitter with
electromagnetic sensorShort Instruction (KA)02/19Tiếng Anh -
Protective Cover connection compartment
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Weather Protection
Installation Instructions
Promag, Promass 300, 500, Prosonic Flow 300
Mounting Instruction (EA) -
Replacing the electronics
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Conversion Kit for Promag, Promass 300 Compact Version to Promag,
Promass 500 Remote Version
Installation Instructions
Promag, Promass 300, 500
Mounting Instruction (EA) -
Alteration with correspondent I/O hardware for HART, Modbus
Installation Instructions
Promag, Promass 300, 500, 500-digital
Mounting Instruction (EA) -
Activating application packages, switching the I/O function, upgrading
with additional I/O hardware
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Display module
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
DKX001–Mounting Instruction (EA) -
Terminal connection
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Replacing RJ45-M12 Adapter
Proline 300, 500-digital
Mounting Instruction (EA) -
Replacing Spare Parts
Installation Instructions
Promag, Promass 100, CNGmass, LNGmass, LPGmass, Promag 400 Index C,
Promag, Promass 300, 500, 500-digital, Prosonic Flow E 100, Pros
onic Flow E Heat, Prosonic Flow 300, 500-digialMounting Instruction (EA) -
Replacing cover, O-ring cover, Interface gasket
Installation Instructions
Promag, Promass 300, 500, Prosonic Flow 300
Mounting Instruction (EA) -
Kit wireless antenna for extended range
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Alteration with display and operating module DKX001
Installation Instructions
Promag, Promass, Prosonic Flow 300
Mounting Instruction (EA) -
Alteration to Display module, to Display module with WirelessHART or
Display module with WLAN
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Cover for remote display module, O-ring for cover
Installation Instructions
Promag, Promass, Prosonic Flow 300
Mounting Instruction (EA) -
Replacing the transmitter Promag, Promass 300
Installation Instruction
Promag 300, Promass 300Mounting Instruction (EA) -
Replacing cover, O-ring, seal housing for transmitter wall mounting and
seal housing for the sensor side
Installation Instructions
Promag, Promass 500, 500-digital, Prosonic Flow 500-digital
Mounting Instruction (EA) -
Replacing the S-DAT
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalMounting Instruction (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital
Mounting Instruction (EA) -
Proline Promass 300
CSA:
Class I, Zone 1
Zone 21
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
ATEX:
II3G
IECEx:
Zone 2
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 300
CSA:
Class I, Zone 2
Class I, Division 2
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
JPN:
特別危険箇所/第 1 類危険箇所、第 1 類危険箇所、ゾーン 21
Ex d バージョン
安全上の注意事項
危険場所に関する関連資料
Ex Safety Instructions (XA) -
Proline Promass 300
INMETRO:
Zona 2
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 300
Class I, II, III Division1 for XP
(Ex d Flameproofed version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
NEPSI:
Zone 0/1
Zone 1
Zone 21
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
ATEX:
II2G, II1/2G
II2D
IECEx:
Zone 1, Zone 0/1
Zone 21
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 300
INMETRO:
Zona 0/1
Zona 1
Zona 21
Instruções de segurança
Documentação para áreas classificadas
Ex Safety Instructions (XA) -
Proline Promass 300
NEPSI:
Zone 2
Ex nA version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 300
PROFIBUS PA
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
PROFIBUS PA
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
PROFINET
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
Modbus RS485
Petroleum application package
Special Documentation
Coriolis flowmeter
Petroleum application packageSpecial Documentation (SD) -
Proline Promass 300
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
PROFIBUS DP
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
PROFIBUS PA
Petroleum application package
Special Documentation
Coriolis flowmeter
Petroleum application packageSpecial Documentation (SD) -
Proline Promass 300
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
FOUNDATION Fieldbus
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
EtherNet/IP
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
EtherNet/IP
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
PROFIBUS DP
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
PROFIBUS PA
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Remote display and operating module DKX001
Special Documentation
Remote display and operating module DKX001
Special Documentation (SD) -
Heating jacket
For Promass E Coriolis flowmeters
Special Documentation
Heating jacket
For Promass E Coriolis flowmetersSpecial Documentation (SD) -
Proline Promass 300
Functional Safety Manual
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
EtherNet/IP
Petroleum application package
Special Documentation
Coriolis flowmeter
Petroleum application packageSpecial Documentation (SD) -
Proline Promass 300
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
PROFINET
Petroleum application package
Special Documentation
Coriolis flowmeter
Petroleum application packageSpecial Documentation (SD) -
Proline Promass 300
HART
Petroleum application package
Special Documentation
Petroleum application package
Special Documentation (SD) -
Proline Promass 300
HART
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
Modbus RS485
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 300
PROFINET
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Proline Promass 300
HART
OPC-UA Server application package
for IIoT and SCADA applications
Special Documentation
Special Documentation
OPC-UA Server
For IIoT and SCADA applicationsSpecial Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation
Special documentation
Display modules A309/A310
Display with WLAN interfaceSpecial Documentation (SD) -
Proline Promass 300
FOUNDATION Fieldbus
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
PROFIBUS DP
Petroleum application package
Special Documentation
Coriolis flowmeter
Petroleum application packageSpecial Documentation (SD) -
Proline Promass 300
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300
FOUNDATION Fieldbus
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Proline Promass 300
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 300 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300 500 HART: 1.05.00Manufacturer Information (MI) -
Proline Promass 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promass 300 500 Modbus RS485: 1.01.01Manufacturer Information (MI) -
Proline Promass 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promass 300 500 HART: 1.01.01Manufacturer Information (MI) -
Proline Promass 300 / 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300 / 500 PROFIBUS PA: 1.01.00Manufacturer Information (MI) -
Proline Promass 300 / 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promass 300 / 500 Modbus RS485: 1.02.00Manufacturer Information (MI) -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17Tiếng Anh -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17Tiếng Đức -
Proline 300/500
La technologie de mesure de débit orientée vers l’avenir
Innovations (IN)09/18fr -
Proline 300/500
American version: The future-oriented flow measuring technology
Innovations (IN)05/16Tiếng Anh -
Proline 300/500
Technologie měření průtoku orientovaná na budoucnost
Innovations (IN)05/16Tiếng Séc -
Proline 300/500
La tecnología de medición de caudal del futuro
Innovations (IN)05/16Tiếng Tây Ban Nha -
Proline 300/500
La tecnologia di misura della portata orientata al futuro
Innovations (IN)05/16Tiếng Ý -
Proline 300/500
Die zukunftsweisende Durchfluss-Messtechnik
Innovations (IN)03/18Tiếng Đức -
流量計 Proline 300/500
未来志向の流量測定技術
Innovations (IN)03/18Tiếng Nhật -
Proline 300/500
The future-oriented flow measuring technology
Innovations (IN)03/18Tiếng Anh -
GSD Single, GSD_PA_FL_Promass300500_0x156D_0x02, 12.11.2018 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_PA_FL_Promass300_500_0x156D_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promass_300500_0x156F_0x01_0x01, 04.06.2018 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promass300500_0x843B_0x01_0x01, 16.11.2017 (Flow, Promass 300 500, 0x843B)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promass300500_0x843B_0x02, 10.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EIP_FL_Promass_300500_0x103B_0x01_0x01, 27.11.2018 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.2Language neutral -
EDD Single, AMS11_HART_FL_Promass300_500_0x113B_0x06_0x01, 30.10.2019 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x01_0x01, 21.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass300_500_0x156D_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PDM Version: 6.1, 8.2.1, 9.0, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promass300_500_0x843B_0x02_0x01, 20.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promass_300500_0x103B_0x01_0x01, 17.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 10.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x06_0x01, 30.10.2019 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FCx75_HART_FL_Promass300500_0x113B_0x01_0x01, 17.02.2017 (Flow, Promass 300 500, 0x113B)
HART, Package: Package, Variant: Variant
FC475 Version: 2.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promass300500_0x156D_0x02_0x01, 18.01.2019 (Flow, Promass 300 500, 0x156D)
PROFIBUS PA,
PDM Version: 8.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promass300_500_0x843B_0x01_0x01, 27.11.2017 (Flow, Promass 300 500, 0x843B)
PROFINET,
PDM Version: 8.2.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass300_500_0x113B_0x02_0x01, 22.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x003B_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 6.1, 8.2.1, 9.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_FL_Promass300_500_0x113B_0x01_0x01, 21.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promas300500_0x156F_0x01_0x01, 16.07.2018 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass300_500_0x113B_0x02_0x01, 22.11.2018 (Flow, Promass 300 500, 0x113
HART,
AMS Version: 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x113B_0x02_0x01, 27.11.2017 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 8.2.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promass300500_0x103B_0x01_0x01, 29.09.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass300_500_0x113B_0x06_0x01, 20.11.2019 (Flow, Promass 300 500, 0x113B)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x113B_0x06_0x01, 28.10.2019 (Flow, Promass 300 500, 0x113B)
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x103B)
FOUNDATION Fieldbus H1,
AMS Version: 11.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x113B_0x02_0x01, 28.11.2017 (Flow, Promass 300 500, 0x113B)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promass300_500_0x003B_0x01_0x01, 03.08.2016 (Flow
, Promass 300 500, 0x113B)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promass_300_500_0x103B_FF_FW1_00_zz_Dev_Rev_01, 09.07.2019 (Flow, Promass 300 500, 0x10
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 4.1
Plant Resource Manager Version: R3.20Device Type Manager (DTM)1.9.0.197Language neutral -
DTM Single, Promass_300_500_0x003B_FW_1_00_zz_Dev_Rev_1, 09.07.2019 (Flow, Promass 300 500, 0x113B)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.8.0.224Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_00_zz_Dev_Rev_1, 13.07.2019 (Flow, Promass 300 500, 0x643
Modbus RS485,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.8.0.139Language neutral -
DTM Single, Promass_300_500_8x3x_8x5x_FW_1_00_zz_Dev_Rev_1, 09.07.2019 (Flow, Promass 300 500, 0x15
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.8.0.128Language neutral -
DTM Single, Promass_300_500_HART_FW_1_05_zz_Dev_Rev_06, 04.10.2019 (Flow, Promass 300 500, 0x113B)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.03.00
Field Device Manager Version: R500
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.39.0.627Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 04.10.2019 (Flow, Promass 300 500, 0x64
Modbus RS485,
DeviceCare Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.289Language neutral -
DTM Single, Promass_300_500_MR4_FW_1_05_00_Dev_Rev_06, 04.10.2019 (Flow, Promass 300 500, 0x643B)
Modbus RS485,
DeviceCare Version: 1.03.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.289Language neutral -
DTM Single, Promass300500_PN-CDIE_FW_1_01_zz_Dev_Rev_02, 16.09.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
DeviceCare Version: 1.05.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.222Language neutral -
DTM Single, Promass_300_500_8x3x-8x5x_FW_1_01_zz_Dev_Rev_02, 09.07.2019 (Flow, Promass 300 500, 0x1
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0Device Type Manager (DTM)1.12.0.193Language neutral -
DTM Single, Promass_300_500_DP_FW_1_00_zz_Dev_Rev_01, 10.07.2019 (Flow, Promass 300 500, 0x156F)
PROFIBUS DP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0Device Type Manager (DTM)1.11.0.93Language neutral -
DTM Single, Promass_300_500_EIP_FW_1_00_zz_Dev_Rev_01, 13.07.2019 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Unity Pro XL Version: 12.0Device Type Manager (DTM)1.10.0.94Language neutral -
DTM Single, Promass_300_500_EIP-CDIE_FW_1_00_zz_Dev_Rev_01, 13.07.2019 (Flow, Promass 300 500, 0x10
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.94Language neutral -
DTM Single, Promass_300_500_HART_FW_1_01_zz_Dev_Rev_02, 09.07.2019 (Flow, Promass 300 500, 0x113B)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.10.0.441Language neutral -
DTM Single, Promass_300_500_MR4_FW_1_01_zz_Dev_Rev_02, 13.07.2019 (Flow, Promass 300 500, 0x643B)
Modbus RS485,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.237Language neutral -
DTM Single, Promass_300_500_MR4-CDIE_FW_1_01_zz_Dev_Rev_2, 13.07.2019 (Flow, Promass 300 500, 0x643
Modbus RS485,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.237Language neutral -
DTM Single, Promass300500_PN-CDIE_FW_1_00_zz_Dev_Rev_01, 13.07.2019 (Flow, Promass 300 500, 0x843B)
PROFINET,
FieldCare Version: 2.13.00Device Type Manager (DTM)1.10.0.115Language neutral -
AOP Single, RS_EIP_FL_Promass300500_0x103B_0x01_0x01_AOP, 28.08.2019 (Flow, Promass 300 500, 0x103B)
EtherNet/IP,
RA RSLogix 5000 Version: V20.04and later
RA Studio 5000 Version: V21 and laterAdd On Profile (AOP)1.19Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x003B_0x01_0x01, 03.08.2016 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x113B_0x02_0x01, 28.11.2017 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_FL_Promass_300500_0x103B_0x01_0x01, 15.03.2017 (Flow, Promass 300 500, 0x1
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.20Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass300_500_0x113B_0x06_0x01, 28.10.2019 (Flow, Promass 300 500, 0
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 25.10.2019 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 25.10.2019 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 25.10.2019 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 25.10.2019 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 25.10.2019 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 25.10.2019 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.03Language neutral -
Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass A, Promass E, Promass F, Promass Q
Product Code: 8E3B-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8F5B-, 8PE-, 8Q3B-, 8Q5B-, 8RE-, O8E1B-, O8E1C-, O8E3B-, O8E5B-, O8F1B-, O8F3B-, O8F5B-, O8Q3B-, O8Q5B-, 8E2B-, 8E1C-, 8E1B-, 8BE-, 8A5C-, 8A5B-, 8A3C-, 8A3B-, 8A2B-, 8A1B-, 84F-, 84A-, 83F-, 83E-, 83A-, 80F-, 80E-, 80A-, 40E-
Declaration Number: HE_00351_04.16
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationTiếng Anh -
Dosimass, Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F
Product Code: 8RE-, 8PE-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 8CE-, 8BE-, 84F-, 83F-, 83E-, 80F-, 80E-, 40E-
Declaration Number: HE_01000_02.18
Manufacturer Specification: Food hygieneManufacturer DeclarationTiếng Đức , Tiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Declaration Number: EC_00405_06.16EU DeclarationTiếng Đức , Tiếng Anh -
Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-
Declaration Number: EC_00053_04.15EU DeclarationTiếng Đức , Tiếng Anh , fr -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Declaration Number: EC_00406_04.16EU DeclarationTiếng Đức , Tiếng Anh -
Promass F, Promass E, Promass X, Promass O, Promass I, Promass Q, Promass A, Promass S, Promass P, Promass H
Product Code: 8Q5B-, 8F5B-, 8I5B-, 8E5B-, 8X5B-, 8S5B-, 8O5B-, 8P5B-, 8H5B-, 8Q3B-, 8A5B-, 8I3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8A5C-, 8A3C-
Declaration Number: EC_00424_04.16EU DeclarationTiếng Đức , Tiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Declaration Number: EC_00405_07.16EU DeclarationTiếng Đức , Tiếng Anh -
Promass X, Promass F, Promass E, Promass 83, Promass P, Promass S, Promass I, Promass O, Promass H, Promass A, Promass 84, Promass 80, Promass 40
Product Code: 8E1B-, 83F-, 83E-, 83H-, 83I-, 83P-, 83M-, 83S-, 83A-, 8F2B-, 8F1B-, 8I1B-, 8S1B-, 83O-, 83X-, 8A1B-, 80F-, 80E-, 80H-, 8E2B-, 80I-, 84F-, 80P-, 80S-, 8O1B-, 80A-, 8P5B-, 8I5B-, 8H5B-, 8S5B-, 8F5B-, 8F3B-, 8E3B-, 8E5B-, 8S3B-, 8I3B-, 8O3B-, 8P3B-, 8H3B-, 8X3B-, 84A-, 8A5B-, 8A3B-, 40E-, 8X5B-, 8S1C-, 8E2C-, 84X-, 8A5C-, 8A3C-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousTiếng Nga -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80
Product Code: 8I5B-, 8O1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q1B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X1B-, 8X3B-, 8X5B-, O8X5B-, 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8H1B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8A5B-, 8A3B-, 8A1B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC № RU D-CH.MU62.B.02411MiscellaneousTiếng Nga -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,DExplosion ProtectionTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D T6...T1, I/2/A,B,C,D A,B,C,D, I/2/A,B,C,DExplosion ProtectionTiếng Anh -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3B-, 8A3C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 21, zone 0,1Explosion ProtectionTiếng Trung Quốc -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Region/Country: South Africa
Approval Agency: SABS
Category: zone 1, zone 2, zone 0, zone 21,22Explosion ProtectionTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I,II,III/1/A,B,C,D,E,F,G T6...T1, I,II,III/1/A,B,C,D,E,F,G A,B,C,D,E,F,G, I,II,III/1/C,D,E,F,G T6...T1, I,II,III/1/C,D,E,F,G C,D,E,F,GExplosion ProtectionTiếng Anh -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass Q, Promass P, Promass S, Promass H, Cubemass C
Product Code: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8C3B-, 8A3B-, 8A3C-, O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionTiếng Nhật -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H
Product Code: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8A3C-, O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Region/Country: Brazil
Approval Agency: INMETRO
Category: zone 1, zone 21, zone 0,1
Protection: Ex ia, Ex tb, Ex db eb, Ex dbExplosion ProtectionTiếng Bồ Đào Nha -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass Q, Promass P, Promass S, Promass H
Product Code: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8A3C-, O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Region/Country: Brazil
Approval Agency: INMETRO
Category: zone 2
Protection: Ex ecExplosion ProtectionTiếng Bồ Đào Nha -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2Explosion ProtectionTiếng Trung Quốc -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3C-, 8A3B-
Region/Country: Europe (ATEX)
Approval Agency: SIRA
Protection: Ex tb, Ex db eb ia, Ex dbExplosion ProtectionTiếng Anh -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3C-, 8A3B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex tb, Ex db eb, Ex dbExplosion ProtectionTiếng Anh -
Cubemass C, Promass F, Promass E, Promass P, Promass I, Promass S, Promass H, Promass O, Promass A, Promass Q, Promass X
Product Code: O8X3B-, 8F3B-, 8S3B-, 8E3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8Q3B-, 8X3B-, 8A3B-, 8C3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 21, zone 0,1Explosion ProtectionTiếng Trung Quốc -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8C1B-, 8A3C-, 8A3B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex ecExplosion ProtectionTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionTiếng Anh -
Promass A, Promass F, Promass E, Promass P, Promass I, Promass S, Promass H, Promass O, Promass Q, Promass X
Product Code: 8Q5B-, 8P5B-, 8I5B-, 8S5B-, 8O5B-, 8H5B-, 8F5B-, 8F3B-, 8S3B-, 8E5B-, 8E3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8Q3B-, 8X3B-, 8A5B-, 8A3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3C-, 8A5C-
Region/Country: Russia, Russia (TR CU)
Approval Agency: EAC
Protection: Ex tb [ia Da] IIIC Txxx°C Db, Ex nA [ia Ga] IIC T5 Gc, Ex d e [ia Ga] IIC IIC Gb, Ex d e [ia Ga] IIB IIB Gb, Ex d [ia Ga] IIC T6...T1 Gb, Ex d [ia Ga] IIC T6...T1 Ga/Gb, Ex tb IIIC Txxx°C Db, Ex nA IIIC IIIC Gc, Ex nA IIC T6...T1 Gc, Ex ia IIC T6...T1 Gb, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIB T6...T1 Gb, Ex ia IIB T6...T1 Ga/Gb, Ex d IIC T6...T1 Gb, Ex d IIC T6...T1 Ga/Gb, [Ex ia] IIIC, [Ex ia] IICExplosion ProtectionTiếng Nga -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H, Cubemass C
Product Code: 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8C3B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex d [ia], Ex tbExplosion Protection -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1,2Explosion ProtectionTiếng Anh -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8C3B-, 8C5B-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-, 8O5B-, 8P3B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,G, I/1/A,B,C,D, I/1/C,D,E,F,GExplosion ProtectionTiếng Anh -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass Q, Promass S, Promass X
Product Code: O8X3B-, O8Q3B-, O8O3B-, O8F3B-, O8E3B-, 8X3B-, 8S3B-, 8Q3B-, 8P3B-, 8O3B-, 8I3B-, 8H3B-, 8F3B-, 8E3B-, 8C3B-, 8A3B-, 8A3C-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2Explosion ProtectionTiếng Trung Quốc -
Promass A, Promass E, Promass F, Promass I, Promass K, Promass P, Promass Q, Promass S
Product Code: 8I5B-, 8K1B-, 8P1B-, 8P3B-, 8P5B-, 8Q1B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8I3B-, 8I1B-, 8F5B-, 8F3B-, 8F1B-, 8E5B-, 8E3B-, 8E1C-, 8E1B-, 8A5B-, 8A3B-, 8A1B-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentTiếng Anh -
Promass E
Product Code: 8E1B-, 8E1C-, 8E2B-, 8E2C-, 8E3B-, 8E5B-, O8E1B-, O8E1C-, O8E3B-, O8E5B-
Region/Country: Europe
Approval Agency: TNOHygienic EquipmentTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8A3B-, 8C3B-, 8E3B-, 8F3B-, 8H3B-, 8I3B-, 8O3B-, 8P3B-, 8Q3B-, 8S3B-, 8X3B-, 8A3C-
Region/Country: International
Approval Agency: OPC Foundation
Software Version: 01.01.03Fieldbus ConformanceTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.01.01Fieldbus ConformanceTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: O8O5B-, O8O3B-, 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5B-, 8A3B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Cubemass C
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8C5B-, 8C3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.05.00Fieldbus ConformanceTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-
Region/Country: International
Approval Agency: ODVA
Software Version: 01.00.04Fieldbus ConformanceTiếng Anh -
Promass F, Promass O, Promass E, Promass X, Promass I, Promass Q, Promass P, Promass A, Promass S, Promass H, Cubemass C
Product Code: 8Q5B-, 8F5B-, 8O5B-, 8I5B-, 8E5B-, 8X5B-, 8S5B-, 8P5B-, 8H5B-, 8Q3B-, 8F3B-, 8A5B-, 8I3B-, 8O3B-, 8E3B-, 8X3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8C5B-, 8C3B-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceTiếng Anh -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q
Product Code: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8A5B-, 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8A3B-
Region/Country: Singapore
Approval Agency: Spring
Approval Number: WMO/PA/376MetrologyTiếng Anh -
Promass F, Promass E, Promass O, Promass A, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H, Promass G, Promass 84, Promass 83, Promass 80, Promass 40
Product Code: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8I5B-, 8S5B-, 8P5B-, 8H5B-, 8Q3B-, 8A5B-, 8F3B-, 8O3B-, 8E3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8H1B-, 8O1B-, 8S1B-, 8G1B-, 8S1C-, 8F2B-, 8E2B-, 83F-, 83E-, 8E1C-, 83A-, 83I-, 83S-, 83H-, 83P-, 8E2C-, 80F-, 83O-, 83X-, 80E-, 80A-, 80I-, 80P-, 80S-, 40E-, 80H-, 84X-, 84O-, 84F-, 84A-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6721MetrologyTiếng Nga -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass Q
Product Code: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8A5B-, 8Q3B-, 8F3B-, 8O3B-, 8E3B-, 8X3B-, 8A3B-
Region/Country: Singapore
Approval Agency: Spring
Approval Number: WMO/PA/377MetrologyTiếng Anh -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8X1B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5B-, 8A3B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 66949MetrologyTiếng Nga -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X5B-, 8X3B-, 8X1B-, 8S5B-, 8S3B-, 8Q5B-, 8Q3B-, 8P5B-, 8P3B-, 8O5B-, 8O3B-, 8I5B-, 8I3B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8E5B-, 8E3B-, 8A5B-, 8A3B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 66949MetrologyTiếng Nga -
Promass E
Product Code: 8E3B-, 8E5B-
Region/Country: International
Approval Agency: DNVGLMarineTiếng Anh -
Promass E, Promass F, Promass H, Promass O, Promass Q, Promass X
Product Code: 8X5B-, 8X3B-, 8Q5B-, 8Q3B-, 8O5B-, 8O3B-, 8O1B-, 8H1B-, 8F5B-, 8F3B-, 8F1B-, 8E5B-, 8E3B-, 8E1C-
Region/Country: International
Approval Agency: LRMarineTiếng Anh -
Promass E, Promass F, Promass O, Promass Q, Promass X
Product Code: 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8O1B-, 8O3B-, 8O5B-, 8Q3B-, 8Q5B-, 8X3B-, 8X5B-
Region/Country: International
Approval Agency: RM RSMarineTiếng Nga -
Promass E
Product Code: 8E3B-, 8E5B-
Region/Country: International
Approval Agency: BVMarineTiếng Anh -
Promass E, Promass F, Promass O, Promass Q, Promass X
Product Code: 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8O3B-, 8O5B-, 8Q3B-, 8Q5B-, 8X3B-, 8X5B-
Region/Country: International
Approval Agency: ABSMarineTiếng Anh
Phụ kiện / Phụ tùng thay thế
-
-
Nr 31 Order code 71323007
Kit power supply, 100-230VAC, Ex
Usage: Promag/Promass 300/500, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323008
Kit power supply, 24VDC, Ex
Usage: Promag/Promass 300/500, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass 300/500 digital. Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Promag 400(C). (C) = generation index C.
-
-
-
Nr 33 Order code XPD0028-
ISEM electronic module, Promass 300/500
Usage: Promass, Cubemass 300/500
-
-
-
Nr 37 Order code 71323010
Kit module cartridge, 300/500, Ex
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 37 Order code 71323011
Kit module cartridge, 300, Non-haz
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 46 Order code 71323005
-
-
-
Nr 45 Order code 71323073
Kit conn.terminal option A, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 45 Order code 71323074
Kit conn.terminal option B, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71327818
Kit conn.terminal option C, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323075
Kit conn.terminal option A, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323076
Kit conn.terminal option B, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.
-
Nr 45 Order code 71327819
Kit conn.terminal option C, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 49 Order code 71323079
Kit terminal, transm.,remote display,300
Usage: transmitter housing Alu/cast, connection compartment with remote display DKX001. Consists of: 1x connection terminal 4-Pol.
-
-
-
Nr 20 Order code 71323016
Kit cover, sight glass, Alu,Non-haz/Exde
Usage: Promag/Promass 300, transmitter housing Alu, Non-haz. Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323017
Kit cover,glass, Alu, -50oC,Non-haz/Exde
Usage: Promass 300, transmitter housing Alu, Non-haz. Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 21 Order code 71323018
Kit cover, blind, Alu, Non-haz/Exde
Usage: Promag/Promass 300, transmitter housing Alu, Non-haz. Promag/Promass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
Nr 21 Order code 71323019
Kit cover, blind, Alu,-50oC,Non-haz/Exde
Usage: Promass 300, transmitter housing Alu, Non-haz. Promass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 20 Order code 71323020
Kit cover, sight glass, Alu, Exd
Usage: Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
Nr 20 Order code 71323021
Kit cover, sight glass, Alu, -50oC, Exd
Usage: Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 21 Order code 71323022
Kit cover, blind, Alu, Exd
Usage: Promag/Promass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
Nr 21 Order code 71323023
Kit cover, blind, Alu, -50oC, Exd
Usage: Promass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 70 Order code 71323026
Kit cover gasket, sight glass/blind
Usage: Promag/Promass 300/500, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.
-
Nr 70 Order code 71323027
Kit cover gasket,sight glass/blind,-50oC
Usage: Promag 500, Promass 300/500, transmitter housing Alu/cast, Consists of: O-Ring 110,7x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323028
Kit cover, electr.compart., Alu, Non-haz
Usage: Promag/Promass 300, transmitter housing Alu, Non-haz. Consists of: cover Alu, O-Ring 117,1x3,53 HNBR.
-
Nr 22 Order code 71323029
Kit cover,electronic, Alu,- 50oC,Non-haz
Usage: Promass 300, transmitter housing Alu, Non-haz. Consists of: cover Alu, O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323030
Kit cover gasket,electr.compart.,Non-haz
Usage: Promag/Promass 300, transmitter housing Alu, Non-haz. Consists of: 10x O-Ring 117,1x3,53 HNBR.
-
Nr 74 Order code 71323031
Kit cover gasket,electr., -50oC, Non-haz
Usage: Promass 300, transmitter housing Alu, Non-haz. Consists of: O-Ring 117,1x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 22 Order code 71323032
Kit cover, electronic compart., Alu, Ex
Usage: Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.
-
Nr 22 Order code 71323033
Kit cover, electr.compart., Alu,-50oC,Ex
Usage: Promag 500, Promass 300/500, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 74 Order code 71323036
Kit cover gasket, electronic compart.,Ex
Usage: Promag/Promass 300/500, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.
-
Nr 74 Order code 71323037
Kit cover gasket,elect.compart.,-50oC,Ex
Usage: Promag 500, Promass 300/500, transmitter housing Alu/cast, Ex. Consists of: O-Ring 120,2x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 28 Order code 71323044
Kit cover, remote display, Alu
Usage: Remote display DKX001, housing Alu. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.
-
Nr 28 Order code 71323045
Kit cover, remote display, Alu, -50oC
Usage: Remote display DKX001, housing Alu. Consists of: cover Alu, O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 76 Order code 71323048
Kit cover gasket, remote display
Usage: Remote display DKX001, housing Alu/cast. Consists of: 10x O-Ring 88,50x3,53 HNBR.
-
Nr 76 Order code 71323049
Kit cover gasket, remote display, -50oC
Usage: Remote display DKX001, housing Alu/cast. Consists of: O-Ring 88,50x3,53 FVMQ, -50oC/-58oF.
-
-
-
Nr 71 Order code 71323071
Kit interface gaskets, Promass 300/500
Usage: transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface.
-
Nr 71 Order code 71323072
Kit interf.gaskets,Promass 300/500,-50oC
Usage: transmitter housing/sensor or transmitter housing/wall mount. Consists of: O-Ring 88,50x3,53 FVMQ for interface, -50oC/-58oF.
-
Nr 71 Order code 71368491
Kit interface gaskets, Promass 300, hyg.
Usage: transmitter housing/sensor. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x gasket EPDM for interface.
-
-
-
Nr 11 Order code 71368488
Kit protective cover optionA,300,Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71368489
Kit protective cover optionB,300,Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323081
Kit protective cover option A,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323082
Kit protective cover option B,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
-
-
Nr 87 Order code 71343505
Kit weather protection cover, 300/500
Usage: Promag/Promass 300/500, transmitter housing. Consists of: weather protection cover 4404, installation material.
-
-
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 8X3BXX-
-
Order code DKX001-
Remote Display DKX001
-
Order code DKX002-
Connection Cable for Remote Display
Connection Cable for Remote Display DKX001 of Proline 300.
-
Order code XPRFID-
-
Order code DK8003-
Promass sensor, heating jacket, DK8003
Heating medium (e.g. water, steam)
-
-
Sản phẩm cũ