Proline Promass F 100
Coriolis flowmeter
The flowmeter with premium accuracy, robustness and an ultra-compact transmitter
Promass F has a long standing reputation as a highly accurate device under varying process conditions. It is suited for broadest range of applications. Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Promass F 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers. Available with an extra-compact stainless steel hygienic housing it can be placed even into the most compact rigs.
- F
- L
- E
- X
-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
-
Tổng quan về thông số kỹ thuật
-
Max. measurement error
Mass flow (liquid): ±0.1 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +240 °C (–58…+464 °F) -
Max. process pressure
PN 100, Class 600, 63K
-
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
-
Chọn nhanh
Công cụ lựa chọn mã thiết bị
-
Lợi ích
Highest process safety – immune to fluctuating and harsh environments
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in/outlet run needs
Space-saving transmitter – full functionality...
-
Phạm vi ứng dụng
Measuring principle operates independently of physical fluid properties such as viscosity or density
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Device properties
Mass flow: measured error ±0,05...
Tài liệu / Tài liệu hướng dẫn / Phần mềm
-
Proline Promass F 100
Coriolis flowmeter
Technical Information (TI) -
Proline Promass F 100
Coriolis flowmeter
Modbus RS485Operating Instruction (BA) -
Proline Promass F 100
Coriolis flowmeter
EtherNet/IPOperating Instruction (BA) -
Proline Promass F 100
Coriolis flowmeter
PROFIBUS DPOperating Instruction (BA) -
Proline Promass F 100
Coriolis flowmeter
PROFINETOperating Instruction (BA) -
Proline Promass F 100
Coriolis flowmeter
HARTOperating Instruction (BA) -
Proline Promass 100
EtherNet/IP
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 100
PROFINET
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 100
Modbus RS485
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 100
HART
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline Promass 100
PROFIBUS DP
Description of Device Parameters
Coriolis flowmeter
Device Parameter (GP) -
Proline 100
PROFINET
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)12/15Tiếng Anh -
Proline 100
EtherNet/IP
Brief Operating Instructions
Transmitter with
Coriolis sensorShort Instruction (KA)10/17Tiếng Anh -
Proline 100
PROFIBUS DP
Brief Operating Instructions
Transmitter with
Coriolis sensorShort Instruction (KA)10/17Tiếng Anh -
Proline 100
PROFINET
Brief Operating Instructions
Transmitter with
Coriolis sensorShort Instruction (KA)10/17Tiếng Anh -
Proline 100
HART
Brief Operating Instructions
Transmitter with
Coriolis sensorShort Instruction (KA)10/17Tiếng Anh -
Proline 100
Modbus RS485
Brief Operating Instructions
Transmitter with
Coriolis sensorShort Instruction (KA)10/17Tiếng Anh -
Proline Promass F 100
Brief Operating Instructions
Coriolis flowmeter
Short Instruction (KA)09/15Tiếng Anh -
Proline Promass
Brief Operating Instructions
Proline Promass
Part 1 of 2
Coriolis sensorShort Instruction (KA)04/17Tiếng Anh -
Proline Promass F
Brief Operating Instructions
Coriolis sensor
Short Instruction (KA)02/17Tiếng Anh -
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2
Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
Installation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Proline Promass 100
NEPSI:
Zone 2
Ex nA version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 100
INMETRO:
Zone 1
Zone 21
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 100
Class I, Divison1; Zone 1 for IS
(Ex i Intrinsically safe version)
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 100
Modbus RS485
NEPSI:
Zone 1, Zone 21
Ex i version
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promass 100
ATEX:
II3G
IECEx:
Zone 2
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 100
ATEX:
II2G, II1/2G
II2D
IECEx:
Zone 1, Zone 0/1
Zone 21
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promass 100
INMETRO:
Zone 2
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Proline Promag 100, Promass 100
Modbus RS485
Transmitter terminal assignment
Special Documentation
Transmitter terminal assignment
Special Documentation (SD) -
Proline Promass 100
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promass 100
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 100
Heartbeat Verification + Monitoring application package
Special Documentation
Coriolis flowmeter
Special Documentation (SD) -
Heating jacket
For Promass F Coriolis flowmeters
Special Documentation
Heating jacket
For Promass F Coriolis flowmetersSpecial Documentation (SD) -
Proline Promass
Information on the Pressure Equipment Directive
Special Documentation
Coriolis mass flow measuring system
Special Documentation (SD) -
Proline Promass F 100
Proline Promass 80F, 83F
Special Documentation
Reduction in nominal diameter
Special Documentation (SD) -
Proline Promass 100,
Proline Cubemass C 100
"Concentration Measurement" application package
Special Documentation
Coriolis flowmeter
"Concentration Measurement" application packageSpecial Documentation (SD) -
Proline Promass 100, Proline Cubemass C 100
PROFINET
Concentration Measurement application package
Special Documentation
Coriolis flowmeter
Concentration Measurement application packageSpecial Documentation (SD) -
Proline Promass 100
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 100
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 100
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promass 100
Register information Modbus RS485
Special Documentation
Coriolis mass flow measuring system
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Proline Promass 100
Manufacturer information regarding firmware
updates (NE
53)
New firmware version:
Promass 100 PROFIBUS DP: 1.01.01Manufacturer Information (MI) -
Proline Promass 100
Manufacturer information regarding firmware
updates (NE
53)
New firmware version:
Promass 100 EtherNet/IP: 1.01.00Manufacturer Information (MI) -
Proline Promass 100
Manufacturer information regarding firmware
updates (NE
53)
New firmware version:
Promass 100 EtherNet/IP: 1.02.01Manufacturer Information (MI) -
Proline Promass 100
Manufacturer information regarding firmware
updates (NE
53)
New firmware version:
Promass 100 HART: 1.01.01Manufacturer Information (MI) -
Przepływomierze Coriolisa apa_05_2010
MASOWE PRZEPŁYWOMIERZE CORIOLISA
– TECHNIKA POMIAROWA UZNANA NA CAŁYM ŚWIECIEPublications (PU)03/12Người Ba Lan -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17Tiếng Đức -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17Tiếng Anh -
Proline Promass 100 / Promag 100
Der Durchfluss-Spezialist im Kompaktdesign
Volle Funktionalität auf engstem RaumInnovations (IN)11/14Tiếng Đức -
Proline Promass 100 / Promag 100
The flow specialists in a compact design
Full functionality in a small packageInnovations (IN)11/14Tiếng Anh -
Ethernet industriel pour débitmètres Proline
L'intégration système du futur
Innovations (IN)10/15fr -
Proline Promass 100 /Promag 100
Les spécialistes du débit au design compact
Innovations (IN)07/14fr -
Proline Promag/Promass 100
American version: The flow specialist in a compact design
Full functionality in a small packageInnovations (IN)07/13Tiếng Anh -
Proline Promass 100 / Promag 100
Zaawansowane możliwości w kompaktowym wydaniu.
Rodzina kompaktowych przepływomierzy masowych
i elektromagnetycznychInnovations (IN)06/12Người Ba Lan -
Proline Promag/Promass 100
American version: The flow specialist in a compact design
Full functionality in a small packageInnovations (IN)03/16Tiếng Anh -
GSD Single, GSD_PN_FL_Promass100_0x844A_0x01_0x01, 08.01.2016 (Flow, Promass 100)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.01Language neutral -
GSD Single, GSD_DP_FL_Promass100_0x1561_0x01_0x01, 14.04.2014 (Flow, Prom
ass 100, 0x1561)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promass100_0x1561_0x02_0x01, 17.06.2015 (Flow, Promass 100)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EH_EIP_FL_Promass_100_0x104A_0x03_0x01, 23.10.2015 (Flow, Promass 100)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)3.1Language neutral -
EDS Single, EDS_EH_EIP_FL_Promass_100_0x104A_0x02_0x01, 23.10.2015 (Flow,
Promass 100)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)2.1Language neutral -
EDS Single, EDS_EH_EIP_FL_Promass_100_0x104A_0x01_0x01, 23.10.2015 (Flow, Promass 100)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.1Language neutral -
EDD Single, FDM_HART_FL_Promass100_0x004A_0x01_0x01, 31.03.2014 (Flow, Pr
omass 100, 0x004A)
HART,
Field Device Manager Version: R410Electronic Data Description (EDD)1.00.000Language neutral -
EDD Single, FDM_HART_FL_Promass100_0x004A_0x02_0x01, 16.03.2015 (Flow, Promass 100, 0x004A)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.000Language neutral -
EDD Single, AMS11_HART_FL_Promass100_0x004A_0x02_0x01, 21.08.2019 (Flow, Promass 100, 0x004A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass100_0x004A_0x02_0x01, 21.08.2019 (Flow, Promass 100, 0x004A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass100_0x004A_0x02_0x01, 16.03.2015 (Flow, Promass 100, 0x004A)
HART,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promass100_0x004A_0x01_0x01, 21.08.2019 (Flow, Promass 100, 0x004A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promass100_0x004A_0x01_0x01, 31.03.2014 (Flow, Pr
omass 100, 0x004A)
HART,
PDM Version: 6.1, 8.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promass100_0x004A_0x01_0x01, 21.08.2019 (Flow, Promass 100, 0x004A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promass100_0x1561_0x01_0x01, 28.03.2014 (Flow, Prom
ass 100, 0x1561)
PROFIBUS DP,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promass100_0x1561_0x02_0x01, 17.06.2015 (Flow, Promass 100)
PROFIBUS DP,
PDM Version: 6.1, 8.2, 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promass100_8x1B_8x1C_DP_FW1_01_zz_Dev_Rev_2, 19.10.2020 (Flow, Promass 100, 0x1561)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.7.0.141Language neutral -
DTM Single, Promass100_8x1B_PNIO-CDIE_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promass 100, 0x844A)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.0.70Language neutral -
DTM Single, Promass_100_8x1B_8x1C_EIP_FW_1_02_zz_Dev_Rev_3, 05.11.2020 (Flow, Promass 100, 0x104A)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.0.463Language neutral -
DTM Single, Promass100_8x1B_8x1C_EIP-CDIE_FW_1_02_zz_Dev_Rev_3, 05.11.2020 (Flow, Promass 100)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.0.463Language neutral -
DTM Single, Promass_100_8x1B_8x1C_MR4_FW_1_03_zz_Dev_Rev_3, 06.11.2020 (Flow, Promass 100, 0x644A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.1.519Language neutral -
DTM Single, Promass100_8x1B_8x1C_HART_FW1_01_zz_Dev_Rev_2, 27.10.2020 (Flow, Promass 100, 0x004A)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11, R3.12Device Type Manager (DTM)1.4.0.282Language neutral -
DTM Single, Promass_100_8x1B_MR4_FW_1_02_zz_Dev_Rev_2, 06.11.2020 (Flow, Promass 100, 0x644A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.2.0.476Language neutral -
DTM Single, Promass_100_8x1B_EIP_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promass 100, 0x104A)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.2.0.421Language neutral -
DTM Single, Promass100_8x1Bxx_HART_FW1_00_zz_Dev_Rev_1, 23.10.2020 (Flow, Promass 100, 0x004A)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.2.0.226Language neutral -
DTM Single, Promass100_8x1Bxx_DP_FW1_00_zz_Dev_Rev_1, 19.10.2020 (Flow, Promass 100, 0x1561)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.1.0.104Language neutral -
DTM Single, Promass_100_8x1B_MR4_FW_1_01_zz_Dev_Rev_1, 06.11.2020 (Flow, Promass 100, 0x644A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.0Language neutral -
DTM Single, Promass_100_8x1B_EIP_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promass 100, 0x104A)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.0Language neutral -
AOP Single, RS_EIP_FL_Promass100_8x1B_0x104A_0x01_0x01, 10.02.2021 (Flow, Promass 100, 0x104A)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.66.01Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass100_0x004A_0x01_0x01, 31.03.2014 (Fl
ow, Promass 100, 0x004A)
HART,
Plant Resource Manager Version: R3.10Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promass100_0x004A_0x02_0x01, 16.03.2015 (Flow, Promass 100, 0x004A)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
ComDTM Single, CDI_CommDTM, 02.12.2019
Common Device Interface,
DeviceCare Version: 1.05.00
FieldCare Version: 2.13.00Communication DTM2.09.07Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_CDI, 15.05.2020 (Flow)
Common Device Interface,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 15.05.2020 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass A, Promass E, Promass F, Promass Q
Product Code: 8E3B-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8F5B-, 8PE-, 8Q3B-, 8Q5B-, 8RE-, O8E1B-, O8E1C-, O8E3B-, O8E5B-, O8F1B-, O8F3B-, O8F5B-, O8Q3B-, O8Q5B-, 8E2B-, 8E1C-, 8E1B-, 8BE-, 8A5C-, 8A5B-, 8A3C-, 8A3B-, 8A2B-, 8A1B-, 84F-, 84A-, 83F-, 83E-, 83A-, 80F-, 80E-, 80A-, 40E-
Declaration Number: HE_00351_04.16
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationTiếng Anh -
Dosimass, Dosimass OEM, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F
Product Code: 8RE-, 8PE-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 8CE-, 8BE-, 84F-, 83F-, 83E-, 80F-, 80E-, 40E-
Declaration Number: HE_01000_03.18
Manufacturer Specification: Food hygieneManufacturer DeclarationTiếng Đức , Tiếng Anh -
Promass 80, Promass 83, Promass 84, Promass F, Promass Q
Product Code: O8F1B-, 8Q5B-, 8Q3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 84F-, 83F-, 80F-
Declaration Number: EC_00062_05.15EU DeclarationTiếng Đức , Tiếng Anh , fr -
Promass A, Promass E, Promass F, Promass G, Promass H, Promass I, Promass O, Promass P, Promass S, Promass X
Product Code: 8X1B-, 8S1C-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1C-, 8E1B-, 8A1B-
Declaration Number: EC_00241_02.16EU DeclarationTiếng Đức , Tiếng Anh , fr -
Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass S, Promass X
Product Code: O8X1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8F1B-, O8E1B-, 8X1B-, 8S1C-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8F1B-, 8E1B-, O8E1C-, 8E1C-
Declaration Number: EC_00063_05.15EU DeclarationTiếng Đức , Tiếng Anh , fr -
Promass A, Promass E, Promass F, Promass G, Promass H, Promass I, Promass O, Promass P, Promass S, Promass X
Product Code: 8X1B-, 8S1C-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1C-, 8E1B-, 8A1B-
Declaration Number: EC_00253_03.16EU DeclarationTiếng Đức , Tiếng Anh , fr -
Promass A, Promass E, Promass F, Promass G, Promass H, Promass I, Promass O, Promass P, Promass S, Promass X
Product Code: 8X1B-, 8S1C-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1C-, 8E1B-, 8A1B-
Declaration Number: EC_00252_02.16EU DeclarationTiếng Đức , Tiếng Anh , fr -
Promass 80, Promass 83, Promass 84, Promass F, Promass O, Promass X
Product Code: 8X5B-, 8X3B-, 8O5B-, 8O3B-, 8F5B-, 8F3B-, 8F1B-, 84X-, 84F-, 83X-, 83F-, 80F-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC RU C-CH.AD07.B.01791/20MiscellaneousTiếng Nga -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass K, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Promass 40, LPGmass, CNGmass
Product Code: 8O1B-, 8K1B-, 8I5B-, 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8H1B-, 8G1B-, 8FF-, 8FE-, 8F5B-, 8F3B-, 8F1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, D8CB-, 40E-, 80A-, 80E-, 80F-, 80H-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84A-, 84F-, 84X-, 8A1B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8DF-, 8E1B-, 8E3B-, 8E5B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousTiếng Nga -
Promass 80, Promass 83, Promass 84, Promass F, Promass O, Promass X
Product Code: 8X5B-, 8X3B-, 8O5B-, 8O3B-, 8F5B-, 8F3B-, 8F1B-, 84X-, 84F-, 83X-, 83F-, 80F-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC RU C-CH.AD07.B.01791/20MiscellaneousTiếng Nga -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousTiếng Nga -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousTiếng Nga -
Promass 80, Promass 83, Promass 84, Promass F, Prowirl D, Prowirl F, Prowirl O, Prowirl R
Product Code: 7D2B-, 7F2B-, 7O2B-, 7R2B-, 80F-, 83F-, 83X-, 84F-, 84X-, 8F1B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TС RU C-СH.MU62.B.02588MiscellaneousTiếng Nga -
Promass X, Promass F, Promass E, Promass 83, Promass P, Promass S, Promass I, Promass O, Promass H, Promass A, Promass 84, Promass 80, Promass 40
Product Code: 8E1B-, 83F-, 83E-, 83H-, 83I-, 83P-, 83M-, 83S-, 83A-, 8F2B-, 8F1B-, 8I1B-, 8S1B-, 83O-, 83X-, 8A1B-, 80F-, 80E-, 80H-, 8E2B-, 80I-, 84F-, 80P-, 80S-, 8O1B-, 80A-, 8P5B-, 8I5B-, 8H5B-, 8S5B-, 8F5B-, 8F3B-, 8E3B-, 8E5B-, 8S3B-, 8I3B-, 8O3B-, 8P3B-, 8H3B-, 8X3B-, 84A-, 8A5B-, 8A3B-, 40E-, 8X5B-, 8S1C-, 8E2C-, 84X-, 8A5C-, 8A3C-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousTiếng Nga -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A
Product Code: O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1B-, O8A1B-, 8X1B-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1B-, 8A1B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex ia, Ex tDExplosion ProtectionTiếng Anh -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A
Product Code: O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1B-, O8A1B-, 8X1B-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1B-, 8A1B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D, I/zone 2
Protection: AEx/Ex nA IIC T6...T1 GcExplosion ProtectionTiếng Anh -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A
Product Code: 8X1B-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8F1B-, 8E1B-, 8A1B-
Region/Country: Russia
Approval Agency: EACExplosion ProtectionTiếng Nga -
Promass X, Promass F, Promass E, Promass P, Promass I, Promass S, Promass O, Promass H, Promass A, Cubemass C
Product Code: 8A1B-, 8F1B-, 8P1B-, 8E1B-, 8I1B-, 8S1B-, 8O1B-, 8H1B-, 8C1B-, 8X1B-, O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8H1B-, O8I1B-, O8E1B-, O8F1B-, O8C1B-, O8A1B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 0
Protection: Ex iaExplosion ProtectionTiếng Anh -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A
Product Code: O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1B-, O8A1B-, 8X1B-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1B-, 8A1B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex nAExplosion ProtectionTiếng Anh -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A
Product Code: O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1C-, O8E1B-, O8A1B-, 8X1B-, 8S1C-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1C-, 8E1B-, 8A1B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex ia, Ex nA, Ex tbExplosion ProtectionTiếng Nga -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass G, Promass F, Promass E, Promass C, Promass A, Cubemass C
Product Code: O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1C-, O8E1B-, O8C1B-, O8A1B-, 8A1B-, 8C1B-, 8E1B-, 8E1C-, 8F1B-, 8G1B-, 8H1B-, 8I1B-, 8O1B-, 8P1B-, 8S1B-, 8X1B-
Protection: Ex nAExplosion ProtectionTiếng Anh -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass P, Promass S, Promass H, Promass G
Product Code: 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8O1B-, 8H1B-, 8S1B-, 8G1B-, 8E1C-, 8X1B-, O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1C-, O8E1B-, O8A1B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D, I/zone 2
Protection: AEx/Ex nA IICExplosion ProtectionTiếng Anh -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass P, Promass S, Promass H, Cubemass C, Promass G
Product Code: 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8O1B-, 8H1B-, 8S1B-, 8G1B-, 8C1B-, 8X1B-, O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1B-, O8C1B-, O8A1B-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 2 G, II (1) G, II 1/2 G
Protection: [Ex ia Ga], Ex iaExplosion ProtectionTiếng Anh -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass P, Promass S, Promass H, Cubemass C, Promass G
Product Code: 8F1B-, 8P1B-, 8I1B-, 8A1B-, 8E1B-, 8S1B-, 8O1B-, 8H1B-, 8G1B-, 8C1B-, 8S1C-, 8E1C-, 8X1B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 2
Protection: Ex nAExplosion Protection -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass S, Promass P, Promass H, Cubemass C, Promass G
Product Code: 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8O1B-, 8H1B-, 8S1B-, 8G1B-, 8C1B-, 8E1C-, 8X1B-, O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1C-, O8C1B-, O8A1B-, O8E1B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia, Ex tbExplosion ProtectionTiếng Anh -
Promass X, Promass F, Promass E, Promass P, Promass I, Promass S, Promass O, Promass H, Promass A, Promass G
Product Code: O8X1B-, 8P1B-, 8F1B-, 8E1B-, 8I1B-, 8S1B-, 8A1B-, 8H1B-, 8O1B-, 8G1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1B-, O8A1B-, 8X1B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1
Protection: Ex ia, Ex tD A20/A21 IP6XExplosion ProtectionTiếng Anh , Tiếng Trung Quốc -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A, Cubemass C
Product Code: O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1C-, O8E1B-, O8C1B-, O8A1B-, 8X1B-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1C-, 8E1B-, 8C1B-, 8A1B-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex ia, Ex tbExplosion ProtectionTiếng Anh -
Promass X, Promass F, Promass E, Promass P, Promass I, Promass S, Promass O, Promass H, Promass A, Promass G
Product Code: O8X1B-, 8P1B-, 8F1B-, 8E1B-, 8I1B-, 8S1B-, 8A1B-, 8H1B-, 8O1B-, 8G1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1B-, O8A1B-, 8X1B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2
Protection: Ex nAExplosion ProtectionTiếng Anh , Tiếng Trung Quốc -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass P, Promass S, Promass H, Cubemass C, Promass G
Product Code: 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8O1B-, 8H1B-, 8S1B-, 8G1B-, 8C1B-, 8E1C-, 8X1B-, O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1C-, O8E1B-, O8A1B-, O8C1B-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex nAExplosion ProtectionTiếng Anh -
Promass F, Promass E, Promass A, Promass O, Promass X, Promass I, Promass S, Promass P, Promass H, Promass G
Product Code: 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8O1B-, 8H1B-, 8S1B-, 8G1B-, 8E1C-, 8X1B-, O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1C-, O8E1B-, O8A1B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D, II,III/1/E,F,G, I/zone 1
Protection: AEx/Ex ia IIC, Ex ia IICExplosion ProtectionTiếng Anh -
Promass X, Promass S, Promass P, Promass O, Promass I, Promass H, Promass G, Promass F, Promass E, Promass A
Product Code: O8X1B-, O8S1B-, O8P1B-, O8O1B-, O8I1B-, O8H1B-, O8G1B-, O8F1B-, O8E1B-, O8A1B-, 8X1B-, 8S1B-, 8P1B-, 8O1B-, 8I1B-, 8H1B-, 8G1B-, 8F1B-, 8E1B-, 8A1B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D, II,III/1/E,F,G, I/zone 1
Protection: AEx/Ex ia IIC T6...T1 Gb, Ex ia IIC T6...T1 GbExplosion ProtectionTiếng Anh -
Promass A, Promass E, Promass F, Promass I, Promass P, Promass Q, Promass S
Product Code: 8S5B-, 8S3B-, 8S1C-, 8S1B-, 8Q5B-, 8Q3B-, 8Q1B-, 8P5B-, 8P3B-, 8P1B-, 8I5B-, 8I3B-, 8I1B-, 8F5B-, 8F3B-, 8F1B-, 8E5B-, 8E3B-, 8E1C-, 8E1B-, 8A5C-, 8A5B-, 8A3C-, 8A3B-, 8A1B-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentTiếng Anh -
Promass 80, Promass 83, Promass 84, Promass F
Product Code: O8F5B-, O8F3B-, O8F1B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 84F-, 83F-, 80F-
Region/Country: International
Approval Agency: DTUHygienic EquipmentTiếng Anh -
Promass X, Promass F, Promass E, Promass P, Promass I, Promass S, Promass O, Promass H, Promass A, Cubemass C, Promass G
Product Code: 8A1B-, 8F1B-, 8P1B-, 8E1B-, 8I1B-, 8S1B-, 8H1B-, 8O1B-, 8G1B-, 8C1B-, 8S1C-, 8X1B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: 1.00.01Fieldbus ConformanceTiếng Anh -
Promass E, Promass F, Promass H, Promass I, Promass O, Promass P, Promass S, Cubemass C, Promass A, Promass G
Product Code: 8E1B-, 8F1B-, 8H1B-, 8I1B-, 8O1B-, 8P1B-, 8S1B-, 8C1B-, 8G1B-, 8A1B-, 8S1C-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 1.01.03Fieldbus ConformanceTiếng Anh -
Promass A, Promass F, Promass E, Promass I, Promass P, Promass O, Promass S, Promass H, Cubemass C, Promass G
Product Code: 8P1B-, 8F1B-, 8E1B-, 8I1B-, 8S1B-, 8A1B-, 8H1B-, 8O1B-, 8G1B-, 8C1B-, 8S1C-
Region/Country: International
Approval Agency: ODVA
Software Version: MAJOR REV. 03, MINOR REV. 01Fieldbus ConformanceTiếng Anh -
Promass G, Promass F, Promass E, Promass I, Promass P, Promass H, Promass O, Promass S, Promass A, Cubemass C
Product Code: 8S1B-, 8F1B-, 8P1B-, 8E1B-, 8I1B-, 8A1B-, 8H1B-, 8O1B-, 8G1B-, 8C1B-, 8S1C-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0.2Fieldbus ConformanceTiếng Anh -
Promass F, Promass E, Promass O, Promass A, Promass X, Promass Q, Promass I, Promass P, Promass S, Promass H, Promass G, Promass 84, Promass 83, Promass 80, Promass 40
Product Code: 8Q5B-, 8F5B-, 8O5B-, 8E5B-, 8X5B-, 8I5B-, 8S5B-, 8P5B-, 8H5B-, 8Q3B-, 8A5B-, 8F3B-, 8O3B-, 8E3B-, 8I3B-, 8P3B-, 8S3B-, 8H3B-, 8A3B-, 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8H1B-, 8O1B-, 8S1B-, 8G1B-, 8S1C-, 8F2B-, 8E2B-, 83F-, 83E-, 8E1C-, 83A-, 83I-, 83S-, 83H-, 83P-, 8E2C-, 80F-, 83O-, 83X-, 80E-, 80A-, 80I-, 80P-, 80S-, 40E-, 80H-, 84X-, 84O-, 84F-, 84A-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6721MetrologyTiếng Nga -
Promass F, Promass E, Promass A, Promass I, Promass P, Promass S
Product Code: 8F1B-, 8I1B-, 8P1B-, 8A1B-, 8E1B-, 8S1B-, 8F2B-, 8E2B-, 8E1C-, 8S1C-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 55235_1MetrologyTiếng Nga -
Promass 83, Promass E, Promass F, Promass P
Product Code: 83F-, 8E1B-, 8F1B-, 8F2B-, 8P1B-
Region/Country:
Approval Agency: MSST
Approval Number: MSST_2248MetrologyTiếng Nga -
Promass F, Promass Q, Promass I, Promass 83, Promass 84
Product Code: 8Q5B-, 8F5B-, 8I5B-, 8Q3B-, 8F3B-, 8I3B-, 8F1B-, 8I1B-, 83F-, 83M-, 84F-, 8Q1B-, 84M-
Region/Country: USA
Approval Agency: NTEP
Approval Number: NTEP 01-059A10MetrologyTiếng Anh -
Promass E, Promass F
Product Code: 8E1B-, 8F1B-
Region/Country: International
Approval Agency: LRMarineTiếng Anh -
Promass E, Promass F, Promass O, Promass Q, Promass X
Product Code: 8X5B-, 8X3B-, 8Q5B-, 8Q3B-, 8O5B-, 8O3B-, 8O1B-, 8F5B-, 8F3B-, 8F1B-, 8E5B-, 8E3B-, 8E1C-, 8E1B-
Region/Country: International
Approval Agency: CCSMarineTiếng Anh -
Promass E, Promass F, Promass H, Promass O, Promass Q, Promass X
Product Code: 8X5B-, 8X3B-, 8Q5B-, 8Q3B-, 8O5B-, 8O3B-, 8O1B-, 8H1B-, 8F5B-, 8F3B-, 8F1B-, 8E5B-, 8E3B-, 8E1C-
Region/Country: International
Approval Agency: LRMarineTiếng Anh -
Promass E, Promass F
Product Code: 8E1B-, 8E1C-, 8F1B-
Region/Country: International
Approval Agency: RINAMarineTiếng Anh -
Promass F, Promass E
Product Code: 8F1B-, 8E1B-, 8E1C-
Region/Country: International
Approval Agency: RM RSMarineTiếng Nga -
Promass E, Promass F, Promass O
Product Code: 8E1B-, 8E1C-, 8F1B-, 8O1B-
Region/Country: International
Approval Agency: ABSMarineTiếng Anh -
Promass E, Promass F
Product Code: 8E1B-, 8E1C-, 8F1B-
Region/Country: International
Approval Agency: DNVGLMarineTiếng Anh -
Promass E, Promass F
Product Code: 8E1B-, 8E1C-, 8F1B-
Region/Country: International
Approval Agency: BVMarineTiếng Anh -
Cubemass C, Promass A, Promass E, Promass F, Promass H, Promass I, Promass K, Promass O, Promass P, Promass S, Promass X
Product Code: 8X1B-, 8S1B-, 8P1B-, 8O1B-, 8K1B-, 8I1B-, 8H1B-, 8F1B-, 8E1C-, 8E1B-, 8C1B-, 8A1B-
Region/Country: Germany
Approval Agency: TÜV
Approval Number: PC/209/03/144/07-08/14Heartbeat TechnologyTiếng Đức , Tiếng Anh
Phụ kiện / Phụ tùng thay thế
-
-
Nr 47 Order code 71185785
-
-
-
Nr 45 Order code 71185787
Kit connection terminal for Ex-i barrier
Usage: Promass 100, CNGmass, LPGmass, LNGmass. Consists of: 2x Connection terminal 4-Pol.
-
-
-
Nr 30 Order code XPD0005-
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 50 Order code XPD0023-
Display module, 4-wire, 100
Usage: Promag 100, Promass 100, Prosonic Flow E 100.
-
-
-
Nr 21 Order code 71185789
Kit cover, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
Nr 21 Order code 71185790
Kit cover, compact, stainless 1.4301
Usage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover stainless 1.4301. Gasket EPDM for cover.
-
Nr 21 Order code 71185793
Kit cover,ultra compact,stainless 1.4301
Usage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.
-
-
-
Nr 20 Order code 71266334
Kit cover, sight glass, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
Nr 20 Order code 71266335
Kit cover, sight glass, compact, 1.4301
Usage: Promass 100, Promag 100, Prosonic Flow 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.
-
Nr 20 Order code 71266337
Kit cover,sight glass,ultra comp.,1.4301
Usage: Promass 100, Promag 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.
-
-
-
Nr 70 Order code 71185795
Kit housing gaskets, compact, Alu
Usage: Promass 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket EPDM for housing/sensor.
-
Nr 70 Order code 71185797
Kit housing gaskets, compact, stainless
Usage: Promass 100, Prosonic Flow 100. Consists of: Gasket EPDM for cover. Gasket EPDM for housing/sensor.
-
Nr 70 Order code 71185799
Kit hous.gaskets,ultra compact,stainless
Usage: Promass 100, Promass 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor.
-
-
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 71069285
Kit 2 cable glands M20x1.5 INOX Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 71185802
Kit 2 cable glands G1/2" INOX Ex
Consists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2".
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 71185800
Kit 2 cable glands NPT1/2" INOX Ex
Consists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2".
-
-
-
Nr 12 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Order code XPRFID-
-
Order code DK8003-
-
-
Sản phẩm cũ