Proline Prosonic Flow 93T
Ultrasonic flowmeter

Picture of ultrasonic flowmeter Proline Prosonic Flow 93T for monitoring and test measurements ©Endress+Hauser

Portable volume flowmeter Proline Prosonic Flow 93T for measurement of liquids

The Ultrasonic Flow Measuring Principle

The economical flowmeter for easy data transfer via USB stick without additional software

The portable ultrasonic flowmeter Prosonic Flow 93T is designed for temporary monitoring and test measurements with clamp on sensors. It is operated independently of the mains power using a battery. The Prosonic Flow 93T is ideal for conducting verification measurements at existing flow metering points.

Chọn nhanh

Chọn theo đề xuất của chúng tôi
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

hoặc

Công cụ lựa chọn mã thiết bị

Tiếp tục lựa chọn từ tất cả tùy chọn có thể
  • Lợi ích

    • Automatic frequency scan for maximum measuring performance

    • Quick and secure installation – specially designed mounting kits

    • No additional leakage paths – external measurement from outside the pipe

    • Process transparency – diagnostic capability

    • Temporary...

  • Phạm vi ứng dụng

    The sensors are perfectly suited for the non-contact measurement of pure or slightly contaminated liquids, regardless of the pressure or electrical conductivity.

    • Ideal solution for temporary use everywhere precise measurement or verification is required

    • Can be used with all metal and plastic pipes lined or unlined and with composite pipes

    • ...

Tín năng và thông số kỹ thuật

Quay lại

Details

  • Measuring principle

    Ultrasonic flow

  • Product headline

    Portable volume flowmeter for measurement of liquid applications; from outside of the pipe with "Clamp On" sensors

  • Sensor features

    Integrated USB data logging

  • Nominal diameter range

    DN 15...65
    - 1/2"...2 1/2" (-40...+100°C or -40...+150 °C)

    DN 50...300
    - 2"...12" -40...+80 °C or 0...+170 °C)

    DN 100...4000
    - 4"...160" (-40...+80 °C)

  • Max. measurement error

    +/-2.0 %

  • Measuring range

    0....452'389 m3/h

  • Max. process pressure

    No limit

  • Medium temperature range

    DN 15...65
    -40...+150°C
    (-40...+302°F)
    DN 50...300
    -40...+170°C
    (-40...+338°F)
    DN 100...4000
    -40...+80°C
    (-40...+176°F)

  • Degree of protection

    IP 40

  • Display/Operation

    Four line backlit
    touch control

  • Outputs

    Integrated data logger/site manager
    Easy data transfer via USB stick without additional software

  • Inputs

    4...20mA

  • Digital communication

    FXA 193

Tài liệu / Tài liệu hướng dẫn / Phần mềm

Phụ kiện / Phụ tùng thay thế

Nr
Order code
Specification
  • Sản phẩm cũ

Vui lòng chọn thị trường / khu vực của bạn