Tổng quan về thông số kỹ thuật
-
Accuracy
+/- 1 mm (0.04 in)
-
Process temperature
-40…+130 °C
(-40…+266 °F) -
Process pressure absolute / max. overpressure limit
Vacuum …16 bar
(Vacuum … 232 psi) -
Max. measurement distance
50 m (164 ft)
-
Main wetted parts
PTFE antenna
PP or 316L process connections
Phạm vi ứng dụng
Micropilot FMR60 is the first 80GHz radar developed according to the international functional safety directive IEC 61508. The free space radar offers maximum reliability due to the drip-off antenna, improved algorithms and small beam angle. It is used for continuous non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. It also possesses the smart sensor functionality Heartbeat Technology.
80GHz drip-off antenna suited for free space applications up to 50m and offers high beam focusing for vessels with many internal fittings.
Process connections: Threads or flanges
Temperature: –40 to +130°C (–40 to +266°F)
Pressure: –1 to +16bar (–14.5 to +232psi)
Maximum measuring range: 50m (164ft)
Accuracy: ±1mm (0.04in)
W-band: 80GHz
International explosion protection certificates, overfill prevention WHG, SIL, marine approvals, 5-point linearity protocol
Lợi ích
-
Hardware and software developed according to IEC 61508 up to SIL3 in homogeneous redundancy
-
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
-
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
-
Highest reliability even with obstructions in vessels due to small beam angle and Multi-Echo Tracking evaluation
-
Reduction of engineering effort due to an easier integration of the 80GHz radar instrument into the process
-
Innovative drip-off antenna of PTFE for maximum system availability
-
The world's easiest proof test concept for SIL and WHG saves time and costs
Video
-
Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking
-
Unique HistoROM data management concept for safe level measurement
Lựa chọn Extended
-
Sản phẩm cao cấp
- Chức năng cao và tiện lợi
Công nghệ vượt trội
Đơn giản

-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
-
Measuring principle
Level radar
-
Characteristic / Application
For basic level measurement in liquids, pastes and slurries;
non affected by changing media, temperature changes, gas blankets or vapor;
For applications with many obstacles due to the very small beam angle. -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
Safety and reliability with Multi-Echo Tracking
HistoROM
RFID TAG for easy identification -
Supply / Communication
2-wire (HART)
Bluetooth® wireless technology and App (optional) -
Frequency
W-band (~80 GHz)
-
Accuracy
+/- 1 mm (0.04 in)
-
Ambient temperature
-40…+80 °C
(-40…+176 °F) -
Process temperature
-40…+130 °C
(-40…+266 °F) -
Process pressure absolute / max. overpressure limit
Vacuum …16 bar
(Vacuum … 232 psi) -
Main wetted parts
PTFE antenna
PP or 316L process connections -
Process connection
Thread:
G1-1/2", MNPT1-1/2";
Flange:
UNI DN80…DN150 (3"…6") -
Max. measurement distance
50 m (164 ft)
-
Communication
4…20 mA HART,
Additional switch,
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
-
Safety approvals
Overfill protection WHG
SIL 2, SIL 3 -
Design approvals
EN 10204-3.1
-
Options
Display,
Customized parameterization,
Remote operation via SmartBlue App using Bluetooth®,
Gas-tight feed through,
PWIS free -
Application limits
Process temp. > 130 °C (266 °F) -> FMR62
Very aggressive media -> FMR62
Strong turbulences and foam, stilling well and bypass -> FMR5x, FMP5x
Định cấu hình để tải xuống các bản vẽ CAD của sản phẩm này
Chọn theo đề xuất của chúng tôi
-
-- selected coding-- selected label99.999,00<%label%>
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Giá cho mỗi chi tiết
-
<%range%><%price%>
-
- Các add-on tùy chọn
Công cụ lựa chọn mã thiết bị
Thường mua kèm theo
Phụ kiện
Sản phẩm liên quan