Hãy thử tìm kiếm theo từ khóa, đơn hàng hoặc mã sản phẩm hoặc số sê-ri, ví dụ: “CM442” hoặc “Thông tin kỹ thuật”
Nhập ít nhất 2 ký tự để bắt đầu tìm kiếm.
  • Lịch sử
Gammapilot FTG20 - Radiometric point level

Radiometric
Point level detection
Gammapilot FTG20

Geiger-Mueller counter for point level detection with separate transmitter

FTG20
Please Wait (spinning wheel)
Đang tải giá
Giá tạm thời không có sẵn
Price on request
from CHF ??.-
Lọc phép đo / Tác vụ ứng dụng
Nhiệm vụ đo / Ứng dụng

Định cấu hình để tải xuống các bản vẽ CAD của sản phẩm này

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in liquids, sludge or suspensions under exteme process conditions

  • Specialities

    Calculation and sizing with Applicator

  • Supply / Communication

    Relay DPDT:
    19...253VAC, 19...55VDC
    8/16mA:
    11...36VDC, 11..30VDC (Exia)

  • Ambient temperature

    Relay DPDT:
    19...253VAC, 19...55VDC
    8/16mA:
    11...36VDC, 11..30VDC (Exia)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Min. density of medium

    Any

  • Min. conductivity of medium

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Process connection hygienic

    Non-contact

  • Sensor length

    140 mm (5.5")

  • Communication

    Relay DPDT
    8/16mA
    4...20mA

  • Certificates / Approvals

    ATEX, CSA, CSA C/US, IEC Ex, NEPSI, EAC

  • Options

    Sensitivity:
    1x Geiger- counter: 1-8uSv/h,
    2x Geiger- counter: 0,5-4uSv/h
    3x Geiger- counter: 0,3-2,7uSv/h
    Cooling jacket
    Transmitter with compartment for conduit

  • Components

    Isotope: FSG60, FSG61
    Source container: FQG60, FQG61, FQG62, FQG63, QG2000

  • Measuring principle

    Radiometric Limit

  • Characteristic / Application

    Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in solids under exteme process conditions

  • Specialities

    Calculation and sizing with Applicator

  • Supply / Communication

    Relay DPDT:
    19...253VAC, 19...55VDC
    8/16mA:
    11...36VDC, 11..30VDC (Exia)

  • Ambient temperature

    -40...70°C,
    (-40...158°F),
    With cooling jacket:
    0...120°C
    (32...248°F)

  • Process temperature

    Any

  • Process pressure / max. overpressure limit

    Any

  • Min. density of medium

    Any

  • Main wetted parts

    Non-contact

  • Process connection

    Non-contact

  • Process connection hygienic

    Non-contact

  • Sensor length

    140 mm (5.5")

  • Communication

    Relay DPDT
    8/16mA
    4...20mA

  • Certificates / Approvals

    ATEX, CSA C/US, IEC Ex, NEPSI, EAC

  • Options

    Sensitivity:
    1x Geiger- counter: 1-8uSv/h,
    2x Geiger- counter: 0,5-4uSv/h
    3x Geiger- counter: 0,3-2,7uSv/h
    Cooling jacket
    Transmitter with compartment for conduit

  • Components

    Isotope: FSG60, FSG61
    Source container: FQG60, FQG61, FQG62, FQG63, QG2000

Chào mừng đến với Endress+Hauser!

Vui lòng chọn thị trường / khu vực của bạn