Tổng quan về thông số kỹ thuật
-
Accuracy
0.3%
-
Process temperature
-10…+100°C
(+14…+212°F)
135°C for 1h
(275°F for 1h) -
Pressure measuring range
400 mbar…+40 bar
(6...+600psi) -
Measuring cell
+400 mbar…+40 bar
(+6 psi...+600 psi)
Phạm vi ứng dụng
The Cerabar PMP23 is a price-attractive and compact absolute or gauge pressure transmitter. The piezo-resistive measuring cell with flush-mounted 316L diaphragm was designed for applications in the hygienic industry. PMP23 offers various EHEDG and 3-A certified hygienic process connections, materials with FDA conformity, EG1935/2004 conformity, IP69 protection, optional IO-Link and hazardous area certificates. The device can be delivered with customized measuring ranges up to 40bar.
Pressure transducer to measure absolute or gauge pressure in gases or liquids.
Process connections: Flush-mounted hygienic connections, flush mounted thread connections
Process temperature: -10°C to +100°C (-40°F to +212°F) and +135°C (+275°F) for max. 1h
Process pressure: 400mbar to +40bar (6 to 600psi)
Accuracy: ±0.3% of span
International explosion protection certificates, hygienic certificates
Lợi ích
Easy and time-saving installation and set up within the plant due to very compact construction and customizable measuring ranges
IO-Link reduces costs and complexity due to easy configuration via simple configuration tools or through the engineering system
Fully welded process connections maximize process safety by minimizing the use of gaskets
Enhanced process availability is ensured by the stringent use of 316L material and the possibility of IP 69 ingress protection for washdown conditions, as well as the high reproducibility and long-term stability of the product
A high flexibility of use and therefore lower storage costs are guaranteed as the PMP23 is suitable for CIP / SIP cleaning
The PMP23 can support the need for hygienic documentation and traceability in the plant as certification such as EHEDG, 3-A or (EC)1935/2004 are available among other relevant certificates and manufacturing declarations
Video
-
Cerabar PMP23: Part of a strong team for standard applications - Liquiphant, Liquipoint, Cerabar, Ceraphant
-
Pressure measuring principle
Lựa chọn Fundamental
-
Sản phẩm đơn giản
- Dễ lựa chọn, cài đặt và vận hành
Công nghệ vượt trội
Đơn giản

-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
Sản phẩm cũ
-
Measuring principle
Absolute and gauge pressure
-
Characteristic
Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications
-
Supply voltage
10…30 VDC
-
Reference Accuracy
0.3 %
-
Long term stability
0.2 % of URL/year
-
Process temperature
-10 °C…+100 °C
(+14 °F…+212 °F)
+135 °C for 1 h
(+275 °F for 1 h) -
Ambient temperature
-40 °C…+85 °C
(-40 °F…+185 °F) -
Measuring cell
+400 mbar…+40 bar
(+6 psi...+600 psi) -
Max. overpressure limit
160 bar (2400 psi)
-
Process connection
Threads:
G1, M24 -
Process connection hygienic
DIN11851,
Clamp,
SMS,
Varivent,
Universal adapter -
Communication
4...20 mA
IO- Link -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, NEPSI, EAC
-
Design approvals
EN 10204-3.1Final inspection report
Cleaned from oil + grease
Surface roughness measurement -
Hygienic approvals
3A, EHEDG
EG1935/ 2004
-
Measuring principle
Absolute and gauge pressure
-
Characteristic / Application
Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications
-
Supply / Communication
10…30 VDC
-
Accuracy
0.3%
-
Long term stability
0.2% of URL/year
-
Ambient temperature
-40…+85°C
(-40…+185°F) -
Process temperature
-10…+100°C
(+14…+212°F)
135°C for 1h
(275°F for 1h) -
Process pressure absolute / max. overpressure limit
160 bar (2400 psi)
-
Pressure measuring range
400 mbar…+40 bar
(6...+600psi) -
Process connection
Thread:
G1, M24 -
Process connection hygienic
DIN11851,
Clamp,
SMS,
Varivent,
Universal adapter -
Communication
4...20 mA
IO- Link -
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, NEPSI, EAC
-
Design approvals
EN 10204-3.1
Final inspection report
Cleaned from oil + grease
Surface roughness measurement -
Hygienic approvals
3A, EHEDG
EG1935/ 2004
Định cấu hình để tải xuống các bản vẽ CAD của sản phẩm này
Chọn theo đề xuất của chúng tôi
-
-- selected coding-- selected label99.999,00<%label%>
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Giá cho mỗi chi tiết
-
<%range%><%price%>
-
- Các add-on tùy chọn
Công cụ lựa chọn mã thiết bị
Thường mua kèm theo
Phụ kiện