Tổng quan về thông số kỹ thuật
-
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
t50 = 4 s
t90 = 8 s -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
-
Operating temperature range
PT 100:
-200 °C ...600 °C
(-328 °F ... 1.112 °F) -
Max. immersion length on request
Not defined
Phạm vi ứng dụng
The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. The thermometer fulfills the corresponding safety requirements due to various certificates and tests. The use of a transmitter leads to higher accuracy and reliability in comparison to directly wired sensors.
Chemical/pharmaceutical industry
Petrochemical industry
Energy industry
Paper industry
General industrial applications
The TMT162R RTD assembly comprises a measuring insert (Pt100) and an electronic field transmitter with HART®, FOUNDATION Fieldbus™ or PROFIBUS® PA protocol.
Lợi ích
Dual compartment housing
Backlit display with large measured value, bar graph and fault condition indication
Galvanic isolation 2 kV (sensor input to the output)
Wide range of threaded thermowell connections available as standard
Replaceable measuring insert comprising a mineral insulated tube (SS 316L/1.4404)
Approvals for hazardous areas: Flameproof enclosure (Ex d), Intrinsic safety (Ex ia), Non-sparking (Ex nA); marine approval
Aluminum or stainless steel housing, degree of protection IP67, NEMA 4x
Sản phẩm cũ
-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
US style metrical
modular temperature assembly
for heavy duty applications
suitable for hazardous areas
to use with thermowell
backlit display -
Thermowell / protection tube
to be used with thermowell
-
Insert / probe
mineral insulated (MI), flexible
-
Outer diameter protection tube / Insert
Insert Diameter
6,0 mm (0,24'') -
Max. immersion length on request
Not defined
-
Material protection tube/ thermowell
Not defined
-
Optional coating
Not defined
-
Process connection
Thermowell connection
male thread:
G1/2"
NPT1/2"
NPT3/4"
cap nut:
NPT1/2"
M24x1.5 -
Tip shape
Not defined
-
Surface roughness Ra
Not defined
-
Operating temperature range
PT 100:
-200 °C ...600 °C
(-328 °F ... 1.112 °F) -
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
-
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751 -
Response time
depending on configuration
t50 = 4 s
t90 = 8 s -
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
ATEX II
Explosion proof -
Certification
Gost Metrology
Marine approval
Định cấu hình để tải xuống các bản vẽ CAD của sản phẩm này
Chọn theo đề xuất của chúng tôi
-
-- selected coding-- selected label99.999,00<%label%>
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Giá cho mỗi chi tiết
-
<%range%><%price%>
-
- Các add-on tùy chọn
Công cụ lựa chọn mã thiết bị
Thường mua kèm theo
Phụ kiện
Sản phẩm liên quan