Promag 50L
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Documents / Manuals / Software
-
Proline Promag 50L
Technical Information
Electromagnetic flowmeter
The flowmeter with a weight-optimized sensor and a modular electronic
conceptTechnical Information (TI) -
Proline Promag 50
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 50
Description of the device functions (options and inputs). Additional
documentation for Operating Instructions Proline Promag 50.Operating Instruction (BA) -
Proline Promag 50
PROFIBUS DP/PA
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 50
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)11/17English -
Replacing cover and O-ring
Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME,
CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9
2, 93, t-mass 65, Prowirl 72, 73Mounting Instruction (EA) -
I/O-board, subprint, screening sheed
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65Mounting Instruction (EA) -
Replacing amplifier board
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 90, 93, t-mass 65Mounting Instruction (EA) -
Replacing power supply for harsh environment (HE)
Installation Instructions
Promag 50, 53, 55, Promass 40, 80, 83, 84, CNGmass DCI, Cubemass DCI,
Prosonic Flow 93 PMounting Instruction (EA) -
Replacing I/O-board and subprints for harsh environment (HE)
Installation Instructions
Promag 50, 53, 55, Promass 80, 83, 84, CNGmass 8DF, Cubemass 8CN
Mounting Instruction (EA) -
Repair kit cover remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65Mounting Instruction (EA) -
Installing ground disks
Installation Instructions
Promag, 10, 23, 50, 51, 53, 55, Promag 100, 200, 300, 800,
Promag 400 Index CMounting Instruction (EA) -
Interface parts
Installation Instructions
Promag 10, 23, 50, 51, 53, 55, 400, 800
Mounting Instruction (EA) -
Replacing Power supply and display
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65Mounting Instruction (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Mounting Instruction (EA) -
Replacing Sensor parts remote version
Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN,
CNGmass 8DFMounting Instruction (EA) -
Mounting set for wall-mount housing
Installation Instructions
Promag 50, 51, 53, 55, Promass 80, 83, 84, Prosonic Flow 90, 93, t-mass
65Mounting Instruction (EA) -
Replacing the transmitter
Installation Instructions
Promag 10, 23, 50, 53, 55
Mounting Instruction (EA) -
Replacing transmitter parts
Installation Instructions
Promag 50, 51, 53, 55, Promass 40, 80, 83, 84, Prosonic Flow 90, 93,
t-mass 65, Cubemass 8CN, CNGmass 8DFMounting Instruction (EA) -
Replacing amplifier board for harsh environment (HE)
Installation Instructions
Promag 50, 53, 55, Promass 80, 83, 84, Cubemass DCI 8CN, CNGmass DCI 8DF
Mounting Instruction (EA) -
Converting the Transmitter
Installation Instructions
Promag 50, 53 W, L , Promag W, L 400 Index C
Mounting Instruction (EA) -
Replacing S-DAT
Installation Instructions
Promag 23, 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, 8WF, Cubemass
DCI 8CN, CNGmass DCI 8DF, t-mass 65Mounting Instruction (EA) -
Proline Promag 50
Division 1
Ex documentation
Ex-Dokumentationen zu den Betriebsanleitungen Promag 50.
Ex
documentation for the Promag 50 operating instructions.
Documentation Ex relative aux mises en service Promag 50.Ex Safety Instructions (XA) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag 10L, 50L, L 400/800
Supplementary documentation for the Operating Instructions
Special Documentation
Electromagnetic flow measuring system
Special Documentation (SD) -
Proline Promag 50, 53
Functional safety manual
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag L
Device-specific material load diagrams DN 300
(12")
Special documentation
Electromagnetic flow measuring system
Special Documentation (SD) -
Proline Promag 10 and 50
Supplementary information for Promag 10L and 50L, nominal diameters
DN 1400 to 2400 (54
Electromagnetic flow measuring system
Special Documentation (SD) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 2.01.03Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 2.01.02Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 50)
New software version:
Promag 50 PROFIBUS DP: 3.04.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 50)
New software version:
Promag 50 PROFIBUS DP: 3.06.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 2.03.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 2.04.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 50)
New software version:
Promag 50 PROFIBUS PA: 3.04.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 2.01.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 1.06.01Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 2.01.01Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 53)
New software version:
Promag 50 HART: 2.00.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 50)
New software version:
Promag 50 PROFIBUS PA: 2.03.01Manufacturer Information (MI) -
Proline Promag 50
Manufacturer information regarding software
updates (NE 50)
New software version:
Promag 50 PROFIBUS DP: 3.06.10Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Flow measurement in utilities - for the US Market
Energy management in your hands - customized solutions for
compressed air, gas, steam and waterCompetence Brochure (CP)12/10English -
Modern measurement on filling machines
Filling, cleaning and sterilization
Competence Brochure (CP)07/10English -
A 15% cost saving in sludge dewatering by reducing flocculant dosage.
Dewatering of sludge is a process aimed at reducing its volume by
removing as much water as possible. Frequently this is done
mechanically, where the sediment is subjected to a so-called
conditioning
process; this involves changing the structure and properties of the
sediment, weakening the forces binding water to the surface of
particles.
A commonly used method of conditioning is a chemical method and
consists of adding electrolytes to the sludge, such as aluminum sulfate,
ferric sulfate or ferric chloride, or polyelectrolytes based on organic
polymers.Case Studies (CS)06/11English -
Cost transparency through energy monitoring
Data collection and visualization of the energy consumption.
Case Studies (CS)01/13English -
Innovationsbroschüre - Proline Promag 10L/50L - Das schlanke
Durchfluss-Messgerät für Wasser: robust – wirtschaftlich – genau
Der kompakte Allrounder mit starker Performance
Innovations (IN)04/12German -
Innovation brochure - Proline Promag 10L / 50L / 53L
The no-frills flowmeter for water: Robust – Economical – Precise
The compact allrounder
Innovations (IN)03/13English -
Folleto Proline Promag 10L/50L
El caudalímetro electromagnético para aguas. Robusto, ecónómico
y preciso.Innovations (IN)02/12Spanish -
Promag 50 L
electromagnetic flowmeter, microprocessor based and self checking,
compact versionTender Text03/10English -
Promag 50 L
magnetisch-induktives Durchflussmessgerät, mikroprozessorgesteuert und
überwacht
in Kompakt-BauweiseTender Text03/10German -
GSD Single, GSD_EH_DP_FL_Promag_0x1546_0x07_0x02_DPLIB, 17.04.2014 (Flow,
Promag, 0x1546)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.06.10Language neutral -
GSD Single, GSD_EH_PA_FL_Promag_0x0x1525_0x08_0x01_PALIB, 22.04.2014 (Flo
w, Promag, 0x1525)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.06.01Language neutral -
EDD Single, PDM_HART_FL_Promag50_0x0041_0x08_0x01, 12.11.2018 (Flow, Promag, 0x0041)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag50_0x1546_0x07_0x01, 16.01.2019 (Flow, Promag, 0x1546)
PROFIBUS DP,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag50_0x0041_0x09_0x02, 12.11.2018 (Flow, Promag, 0x0041)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag50_0x0041_0x07_0x01, 12.11.2018 (Flow, Promag, 0x0041)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag50D_0x0041_0x09_0x02, 06.08.2015 (Flow, Pro
mag)
HART,
PDM Version: 6.1, 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promag50_0x1525_0x08_0x01, 17.01.2019 (Flow, Promag, 0x1525)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promag_50_PA_V3_06_xx, 06.07.2019 (Flow, Promag, 0x1525)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, Promag_50_DP_V3_06_xx, 06.07.2019 (Flow, Promag, 0x1546)
PROFIBUS DP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, Promag_50_HART_FW2_04_zz_Dev_Rev_9, 10.07.2019 (Flow, Promag, 0x0041)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promag_50_V2_03_xx, 10.07.2019 (Flow, Promag, 0x0041)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, Promag_50_V2_02_xx, 10.07.2019 (Flow, Promag, 0x0041)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Product Family: Promag 10, Promag 50, Promag 53, Promag 55, Promag L,
Promag W
Product Code: 5W4B-, 53W-, 50W-, 53L-, 50L-, 5L4B-, 10W-, 10L-, 55W-, 55L-
Manufacturer DeclarationEnglish -
Promag 50, Promag 51, Promag 53
Product Code: 50D-, 50E-, 50H-, 50L-, 50P-, 50W-, 51P-, 51W-, 53E-, 53H-, 53L-, 53P-, 53W-
Declaration Number: EC_00288_01.16EU DeclarationGerman , English , fr -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRussian -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRussian -
Promag 50, Promag 51, Promag 53
Product Code: 53W-, 53P-, 53H-, 50P-, 50W-, 50H-, 50L-, 50D-, 51W-, 51P-
Region/Country: South Korea
Approval Agency: KTLExplosion Protection -
Promag 50, Promag 53, Promag 51
Product Code: 53W-, 53P-, 53H-, 50P-, 50W-, 50H-, 53L-, 50L-, 53E-, 51W-, 51P-, 50E-, 51L-, 51H-, 51E-
Region/Country: USA
Approval Agency: FM
Protection: XP/IS/DIPExplosion ProtectionEnglish -
Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 55S-, 55H-, 53W-, 53P-, 53L-, 53H-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/T6...T1, I/1/A,B,C,D/T5, II/1/E,F,G/T5
Protection: Ex d e [ia Ga] IIC T6...T1 Gb, ISExplosion ProtectionEnglish -
Promag 50, Promag 53, Promag 51, Promag 55
Product Code: 55S-, 53P-, 53W-, 53H-, 50P-, 50W-, 50H-, 55H-, 53L-, 50L-, 50D-, 53E-, 51W-, 51P-, 50E-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D T6...T1, I/1/A,B,C,D T5, II/1/E,F,G T5
Protection: Ex d e [ia Ga] IIC T6...T1 Gb, NIExplosion ProtectionEnglish -
Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 55S-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D
Protection: NIExplosion ProtectionEnglish -
Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 55W-, 55S-, 55P-, 55L-, 55H-, 55E-, 55D-, 53W-, 53S-, 53P-, 53L-, 53H-, 53E-, 53D-, 51W-, 51S-, 51P-, 51L-, 51H-, 51E-, 51D-, 50W-, 50S-, 50P-, 50L-, 50H-, 50E-, 50D-
Region/Country: USA
Approval Agency: FM
Category: I/2/A,B,C,D/T6...T1, II,III/1/E,F,G/T6...T1
Protection: DIP, NI/ANIExplosion ProtectionEnglish -
Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 55S-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/1/A,B,C,D
Protection: ISExplosion ProtectionEnglish -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: 10W-, 50L-, 50W-, 51W-, 53W-, 5L4C-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5W1B-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag W, Promag 10, Promag 50, Promag 53, Promag L
Product Code: 5W5B-, 5W4C-, 5L4C-, 53W-, 50W-, 53L-, 50L-, 10L-, 10W-, 5W4B-, 5W8B-, O5W1B-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55, Promag L, Promag P, Promag W
Product Code: 5W8C-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5W3B-, 5L8B-, 5L4C-, 5L4B-, 55S-, 53W-, 53L-, 51W-, 50W-, 50L-, 10W-, 10L-
Region/Country: France
Approval Agency: ACSHygienic EquipmentEnglish -
Promag W, Promag 53, Promag 50, Promag 10, Promag L, Promag 51, Promag 55
Product Code: 5W4C-, 53W-, 50W-, 53L-, 50L-, 5W4B-, 5W5B-, 10W-, 10L-, 5W8B-, 5L4C-, 5W8C-, 5W3B-, 5L8B-, 5L4B-, 55S-, 51W-
Region/Country: France
Approval Agency: ACSHygienic Equipmentfr -
Promag 10, Promag 50, Promag 51, Promag 53, Promag L, Promag W
Product Code: O5W1B-, 5W8B-, 5W5B-, 5W4C-, 5W4B-, 5L4C-, 53W-, 51W-, 50W-, 50L-, 10W-
Region/Country: Germany
Approval Agency: HyHygienic EquipmentGerman -
Promag 10, Promag W, Promag 53, Promag 50, Promag 51, Promag L
Product Code: O5W1B-, 53W-, 50W-, 5W4C-, 53L-, 50L-, 5W5B-, 5W4B-, 51W-, 10W-, 10L-, 5W8B-, 5L4C-, 5L8B-
Region/Country: Great Britain
Approval Agency: WRASHygienic EquipmentEnglish -
Promag P, Promag W, Promag 53, Promag 50, Promag D, Promag 51, Promag 10, Promag L
Product Code: 5W8B-, 53P-, 53W-, 50P-, 50W-, 5P1B-, 5W4C-, 5P2B-, 50L-, 5D4C-, 50D-, 5P5B-, 5W5B-, 5W4B-, 51W-, 5P3B-, 5D4B-, 51P-, 10P-, 10W-, 10L-, 10D-, O5W1B-, O5P2B-, O5P1B-, 5L8B-, 5L4C-, 5L4B-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Promag 50
Product Code: 50D-, 50P-, 50W-, 50H-, 50L-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0Fieldbus ConformanceEnglish -
Promag 10, Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 53H-, 53W-, 53P-, 50H-, 50P-, 50W-, 55S-, 55H-, 50D-, 53L-, 53E-, 50L-, 51W-, 51P-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A № 56810_1MetrologyRussian -
Promag 10, Promag 23, Promag 50, Promag 51, Promag 53, Promag 55
Product Code: 55S-, 55H-, 53W-, 53P-, 53H-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50D-, 23P-, 23H-, 10W-, 10P-, 10L-, 10H-, 10D-
Region/Country: Kazakhstan
Approval Agency: MEMST
Approval Number: GOST-12129MetrologyRussian -
Promag 10, Promag 23, Promag 50, Promag 51, Promag 53, Promag E, Promag 55, Promag H, Promag P, Promag W
Product Code: 10E-, 53E-, 53H-, 53L-, 53P-, 53W-, 55H-, 55S-, 5D4-, 5E1B-, 5H1B-, 5H2B-, 5L4-, 5W4-, 5P1B-, 5P2B-, 5W8B-, 10D-, 10H-, 10L-, 10P-, 10W-, 23H-, 23P-, 50D-, 50E-, 50H-, 50L-, 50P-, 50W-, 51P-, 51W-
Region/Country:
Approval Agency: AZSTAND
Approval Number: CH.S.29.999.Ü 001318Metrology -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRussian -
Promag 10, Promag P, Promag 53, Promag W, Promag H, Promag 50, Promag L, Promag 51, Promag 55, Promag D, Promag E
Product Code: 53P-, 53W-, 53H-, 50P-, 50W-, 5P1B-, 50H-, 55S-, 5H1B-, 5W4C-, 5L4C-, 5P2B-, 55H-, 53L-, 50L-, 5D4C-, 5H2B-, 5E1B-, 50D-, 53E-, 5W4B-, 51W-, 5L4B-, 5D4B-, 51P-, 10P-, 10W-, 10H-, 10L-, 50E-, 5W8B-, 10E-, 10D-
Region/Country: Belarus
Approval Agency: BELGIM
Approval Number: 9768MetrologyRussian
Accessories / Spare parts
-
-
Nr F Order code 50096745
Kit P.s.b. 50/51/53 85-260VAC
-
Nr F Order code 71039466
-
Nr F Order code 50096747
Kit P.s.b. 50/51/53 20-55VAC 16-62VDC
-
Nr F Order code 71039468
-
-
-
Nr 7 Order code 50094002
Kit 10 fuses 250 VAC T800 MA
-
Nr 7 Order code 50094003
Kit 10 fuses 250 VAC T 2A00
-
-
-
Nr B Order code 50106073
-
Nr B Order code 71039445
Kit meas. amplifier 50 WEA HE
Language: FR, ES, IT, NL, PT, DE, EN HE = harsh environment
-
Nr B Order code 50106075
-
Nr B Order code 71039447
-
Nr B Order code 50106074
-
Nr B Order code 71039446
Kit meas. amplifier 50 EES HE
Language: SV, FI, NO, RU, PL, CS, EN HE = harsh environment
-
-
-
Nr C Order code 50096759
Kit com50/51/40/80/90 I+F/stat.in+outEx
-
Nr C Order code 71039473
-
Nr C Order code 50096757
-
Nr C Order code 71039474
-
Nr C Order code 71066579
-
Nr C Order code 71066580
-
Nr C Order code 50096756
Kit com Pline 50/90 current out Ex
-
Nr C Order code 71039710
-
Nr C Order code 71021742
Kit I/O 50/53/55/83/65/8ME Profib. DP Ex
-
Nr C Order code 71039484
-
-
-
Nr E Order code 50108132
Kit display mod 50/51/80/65 >=V1.06.00
-
-
-
Nr J Order code 50108131
Kit disp.50/51/80/90/65 Wall >=V1.06.00
-
-
-
Nr 21 Order code 50094017
Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
-
-
-
Nr G Order code 50094016
Kit Bus/connec.b.5X/40/8X/65 field hous.
-
-
-
Nr 19 Order code 50094015
Kit connec. board PMAG5X wall enclo.
-
Nr 19 Order code 71039496
-
-
-
Nr 18 Order code 50094014
Kit connec. board In/Output Wall encl
-
-
-
Nr A Order code 50098018
-
Nr A Order code 71039497
Kit connection board D/E/L/P/S/W FS HE
Usage: 10/50/53/55 HE = harsh environment
-
-
-
Nr 29 Order code 50108139
Kit Termin.Block field hous. 5X/8X/40/65
-
-
-
Nr 30 Order code 50108140
Kit Termin.Block Wall encl. 5X/8X/9X/65
-
-
-
Nr S Order code 71003946
-
-
-
Nr 8 Order code 50094026
Kit Cover 5X/40/8X/65 with window
-
-
-
Nr 9 Order code 50094028
Kit Cover 5X/40/8X/65 version blind
-
-
-
Nr 10 Order code 50094038
-
-
-
Nr 26 Order code 50094038
-
Nr 26 Order code 71247838
Repair kit cover, remote version
Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease
-
-
-
Nr 15 Order code 50096840
Kit 10 cable glands M20x1,5
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098037
Kit Cable gland Profibus PA
-
Nr 15 Order code 71029349
Kit 2 cable gland M20x1,5 reinf.Transm.
-
Nr 15 Order code 71029350
Kit 2 cable gland M20x1,5 reinf.Sensor
-
Nr 15 Order code 71029351
Kit 2 cable glands G1/2" Nema 6P
-
Nr 15 Order code 71029352
Kit 2 cable glands NPT1/2" Nema 6P
-
-
-
Nr 12 Order code 50096839
Kit Circuit board cpl field/SS-housing
-
-
-
Nr 14 Order code 50099102
Kit Bushing to field/SS-housing
-
-
-
Nr 13 Order code 50096841
Kit Ground terminal / Cover clamp
-
-
-
Nr 20 Order code 50094041
Kit Seal cover to Wall enclosure
-
-
-
Nr 11 Order code 50094050
Kit 10 Seal cover to field housing
-
-
-
Nr 22 Order code 50098020
Kit parts housing compact Stnd/HT
Usage: 10/23/50/51/53/55 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 24 Order code 50098019
Kit parts housing FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W
-
-
-
Nr 25 Order code 50098023
Kit housing gasket FS Stnd/HT
Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W
-
-
-
Nr 23 Order code 50098024
Kit housing gasket compact Stnd/HT
Usage: 10/23/50/51/53/55 Sensor: D/E/L/P/S/W
-
-
-
Order code DK5CA-
Promag, cable remote version
10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable
-
Order code 50XXX-
Promag 50, transmitter
-
Order code DK5WM-
-
Order code DK5GC-
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code FXA193-
Serviceinterface FXA193
The service interface connects the service port of Proline and ToF devices with the serial interface RS 232C (9 pin.) of a personal computer. Contents of delivery: - Serviceinterface with RS 232C connection cable (9 pin.) - FXA "USB" cable, the additional power supply for FXA193 from USB-port of the PC.
-
-
Successor