Water & Wastewater (e.g. basins / channels / rivers / dams / lift stations / storm water basins / pump control) Utility applications in all industries Storage tanks
Specialities
Bluetooth® commissioning Operation and maintenance SmartBlue App Heartbeat Verification
Supply / Communication
2-wire (HART, 4…20 mA) Bluetooth® wireless technology and App (optional)
Frequency
W-Band (~80 Ghz)
Accuracy
+/- 2mm (0.08")
Ambient temperature
-40…+80°C (-40…+176°F)
Process temperature
-40…+80°C (-40…+176°F)
Process pressure / max. overpressure limit
-1…3 bar (-14,5…43 psi)
Main wetted parts
PVDF, PBT/PC
Process connection
Thread: G1", NPT1"; G1-1/2", NPT1-1/2" Flange: UNI flange 2“, 3“, 4“ UNI slip on flange 3“, 4“, 6“
Max. measurement distance
30m (98.4 ft)
Communication
4...20 mA HART Bluetooth® wireless technology
Certificates / Approvals
ATEX, C/US, EAC Ex, JPN Ex, KC Ex, INMETRO Ex, NEPSI Ex, UK Ex
Safety approvals
Overfill protection WHG
Hygienic approvals
EU Food Contact Material (EC) 1935/2004 US Food Contact Material FDA CFR 21
Marine approval
ABS, LR, BV, DNV
Drinking water approvals
NSF/ANSI 61
Options
Remote operation via SmartBlue App using Bluetooth® Remote HART indicator RIA15 in order structure Flooding protection tube Different mounting possibilities
Application limits
Process temp. <-40°C (-40°F) or > 80°C (176°F) -> FMR62B Very aggressive media -> FMR62B Turbulences, stilling well and bypass -> FMR62B Strong foam and interfaces --> FMP5x
Measuring principle
Level radar solid
Characteristic / Application
For simple applications: Reliable, non-contact measurement of levels in silos or storage tanks for bulk solids
Specialities
Bluetooth® commissioning Operation and maintenance SmartBlue App Heartbeat Verification
Supply / Communication
2-wire (HART, 4…20 mA) Bluetooth® wireless technology and App (optional)
Frequency
W-Band (~80 Ghz)
Antenna
40 mm/ 1-1/2" 80 mm/ 3"
Accuracy
+/- 2mm (0.08")
Ambient temperature
-40…+80°C (-40…+176°F)
Process temperature
-40…+80°C (-40…+176°F)
Process pressure / max. overpressure limit
-1…3 bar (-14,5…43 psi)
Main wetted parts
PVDF, PBT/PC
Process connection
Thread: G1", NPT1"; G1-1/2", NPT1-1/2" Flange: UNI flange 2“, 3“, 4“ UNI slip on flange: 3“, 4“, 6“
ATEX, C/US, EAC Ex, JPN Ex, KC Ex, INMETRO Ex, NEPSI Ex, UK Ex
Safety approvals
Overfill protection WHG
Hygienic approvals
EU Food Contact Material (EC) 1935/2004 US Food Contact Material FDA CFR 21
Marine approval
ABS, LR, BV, DNV
Drinking water approvals
NSF/ANSI 61
Options
Remote operation via SmartBlue App using Bluetooth® Remote HART indicator RIA15 in order structure Flooding protection tube Different mounting possibilities
Application limits
DK < 1.6 Reduction of the max. possible measuring range due to: Media with poor reflective properties cone of repose extremely loose surface of bulk solids, e.g. bulk solids with a low bulk density during pneumatic filling buildup, especially of moist products. Alternative for these applications: FMR67B
Chúng tôi sử dụng cookie để nâng cao trải nghiệm duyệt web của bạn, thu thập số liệu thống kê để tối ưu hóa chức năng của trang web và cung cấp nội dung hoặc quảng cáo phù hợp.
Bằng cách chọn "Chấp nhận tất cả", bạn đồng ý với việc sử dụng cookie của chúng tôi.
Để biết thêm chi tiết, vui lòng xem lại Chính sách cookie của chúng tôi.