Tổng quan về thông số kỹ thuật
-
Measured variables
Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
-
Measuring range
0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
-
Conformities
ATEX: 2014/34/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
PED: 2014/68/EU
Phạm vi ứng dụng
Detection of flare gas leaks, steam flow measurement, monitoring of gas losses, monitoring of steam injection in flare gas burning as well as process optimization are fields of use for this gas flowmeter FLOWSIC100-Flare-XT. It measures values such as gas velocity, gas volume, mass flow rate, molecular weight, volumetric flow and sound velocity. Additionally, it provides an intelligent device monitoring process and supports predictive maintenance - designed for current and future challenges.
Flare gas measurement for the production and processing of natural gas and associated petroleum gases (APG)
Flare gas measurement in chemical and petrochemical plants
Measurement of LNG boil-off gas
Device properties:
Reliable measurement even at high gas velocities and with changing gas compositions
Direct mass flow calculation without additional gas analyzers
Intuitive FLOWgateTM software for commissioning, operation and diagnostics
Self monitoring, self testing and predictive maintenance
Lợi ích
Several standards and guidelines for flare gas measurement are observed
Maximum plant availability
Compatible with current and future communication architectures
Independent maintenance through verification on demand and support when required
Easy replacement of existing measurement systems, with suitable retrofit or upgrade solutions available
Video
-
Reliable gas flow measurement on flare stacks in petroleum refineries, chemical plants and natural gas processing
Lựa chọn Xpert
-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
| Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
|---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
-
Measuring principle
Ultrasonic transit time difference measurement
-
Measured variables
Mass flow rate, volumetric flow s. c. (standard condition), volumetric flow a. c. (actual condition), molecular weight, gas volume and mass, gas velocity, sound velocity
-
Measuring range
0,03 m/s ... 120 m/s (0.1 ft/s ... 394 ft/s)
-
Max. Measurement error
Volumetric flow, a. c.; 1 % ... 5 %
Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value)
0,5 % ... 1,5 % with spool piece and flow calibration
Related to the measured value with ultrasonic technology (in the range ≥ 1.0 m/s (≥ 3.3 ft/s) to calibration range end value
Mass flow rate a.c.; 2 % ... 5.5 %
Related to the measured value with ultrasonic technology (in the range ≥ 0.3 m/s (≥ 1 ft/s) to measuring range end value)
1,5 % ... 2 % with spool piece and flow calibration
Related to the measured value with ultrasonic technology (in the range ≥ 1 m/s (≥ 3.3 ft/s) to calibration range end value) -
Medium temperature range
-196 °C ... +280 °C
(-320 °F ... +536 °F) -
Operating pressure range
CL150 device flange (1) ATEX/IECEx: 20 bar(g)
CSA: 16 bar(g)
PN25 device flange (optional) (1) ATEX/IECEx: 20 bar(g)
CSA: 16 bar(g)
CL300 device flange (optional) (1) ATEX/IECEx: 20 bar(g)
CSA: 16 bar(g)
(1) Temperature dependent. -
Nominal pipe size
1-path measurement 4 ″ ... 86 ″
2-path measurement 12 ″ ... 86 ″
Other nominal sizes on request -
Conformities
ATEX: 2014/34/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
PED: 2014/68/EU -
Hazardous area approvals
Interface Unit
IECEx:
Zone 1: Ex db eb ia IIC T4 Gb
Zone 1: Ex db ia IIC T4 Gb
Zone 2: EX ec ia IIC T4 Gc
ATEX:
Zone 1: II 2G Ex db eb ia IIC T4 Gb
Zone 1: II 2G Ex db ia IIC T4 Gb
Zone 2: II 3G Ex ec ia IIC T4 Gc
NEC/CEC (US/CA):
Class I, Zone 1, AEx d ia IIC T4 Gb
Class I, Division 1, Groups B, C, D, T4
Class I, Zone 2, AEx ec ia IIC T4 Gc
Class I, Division 2, Group A, B, C and D, T4
Sensors
F1F-S/P/R:
IECEx:
Zone 1: Ex db [ia Ga] IIC T6 Ga/Gb
ATEX:
Zone 1: II 1/2 G Ex db [ia Ga] IIC T6 Ga/Gb
NEC/CEC (US/CA):
Class I, Division 1, Groups B, C and D, T4;
Class I, Zone 1, Ex/AEx d[ia] IIB + H2, T4;
F1F-M:
IECEx:
Zone 1: Ex db [ia Ga] IIB T4 Ga/Gb
ATEX:
Zone 1: II 1/2 G Ex db [ia Ga] IIB T4 Ga/Gb
NEC/CEC (US/CA):
Class I, Division 1, Groups C and D, T4;
Class I, Zone 1, Ex/AEx d[ia] IIB, T4;
F1F-H:
IECEx:
Zone 1: Ex db IIC T6 Gb
ATEX:
Zone 1: II 2 G Ex db IIC T6 Gb
NEC/CEC (US/CA):
Class I, Division 1, Groups B, C and D, T4;
Class I, Zone 1, Ex/AEx d IIB + H2, T4; -
Outputs
Up to 6 outputs when using I/O modules (Option)
16 bit:
4 ... 20 mA
7 V DC ... 30 V DC
In accordance with NAMUR NE43
Passive, galvanically isolated
Reverse polarity protection -
Digital Outputs
Switching output:
Up to 6 outputs when using I/O module (option)
Electrically isolated
Max. current: 70 mA
Max. switching frequency: 50 Hz
Max. input voltage: 30 V DC
Max. saturation voltage at output: 0.5 V DC
Switchable Namur/open collector
Reverse polarity protection
Digital output/Frequency output:
Up to 12 digital outputs when using I/O modules (option)
Electrically isolated
Max. current: 50 mA
Max. switching frequency: 10 kHz
Max. input voltage: 30 V DC
Max. saturation voltage at output: 1.8 V DC
Switchable Namur/open collector
Reverse polarity protection -
Digital communication
HART
MODBUS
FOUNDATION FIELDBUS
-
-
Hướng dẫn vận hành (BA)
FLOWgate – Software Manual
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 03/2025New version available in EnglishThe FLOWgate software provides a user friendly access to
measurement data, configuration and diagnostic of the flow meter.Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/03/2025
Cỡ tập tin:
1.6 MB
Tên tập tin:
8030458_AE00_OI_FLOWgate_en_V1-5_2025-03_EHS.pdf
-
-
-
Hướng dẫn vận hành (BA)
FLOWSIC100 Flare-XT
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 04/2025New version available in EnglishUltrasonic Mass Flow Measuring Device
EN VI 01/04/2025Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/04/2025
Cỡ tập tin:
9.4 MB
Tên tập tin:
8029806_AE00_OI_FLOWSIC100_Flare-XT_en_V2-4_2025-04_EHS.pdf
-
-
-
Hướng dẫn vận hành (BA)
FLOWSIC100 Flare-XT, Device variant F1F-R, 90°
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 03/2025New version available in EnglishSupplement (to be used only in combination with the currently
valid Operating Instructions) to:
● FLOWSIC100 Flare-XT when the F1F-R sender/receiver units are
used with an Interface Unit,
● FLOWSIC100 Flare-XT Transmitter when the F1F-R sender/receiver
units are used as stand-alone Transmitter.Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/03/2025
Cỡ tập tin:
2.8 MB
Tên tập tin:
8030839_AE00_OI_FLOWSIC100_Flare-XT_F1F-R_en_V1-0_2025-03_EHS.pdf
-
-
-
Hướng dẫn vận hành (BA)
FLOWSIC100 Flare-XT Stainless Steel Enclosure
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 04/2025New version available in EnglishDescription of the stainless steel enclosure option which is available
for the Interface Unit. With this additional option, the Interface
Unit can safely be isolated from the corrosive offshore environment.Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/04/2025
Cỡ tập tin:
690.1 KB
Tên tập tin:
8030979_AE00_OI_FLOWSIC100_Flare-XT_Stainless_Steel_Enclosure_en_V1-0_2025-04.pdf
-
-
-
Hướng dẫn vận hành (BA)
FLOWSIC100 Flare-XT Transmitter
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 04/2025New version available in EnglishUltrasonic Mass Flow Measuring Device
EN VI 01/04/2025Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/04/2025
Cỡ tập tin:
6.2 MB
Tên tập tin:
8029804_AE00_OI_FLOWSIC100_Flare-XT_Transmitter_en_V1-3_2025-04_EHS.pdf
-
-
-
Hướng dẫn ngắn gọn (KA)
FLOWgate – Quickstart
-
Hướng dẫn ngắn gọn (KA)
bản tiếng Anh - 03/2025New version available in EnglishInstallation of FLOWgate
Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/03/2025
Cỡ tập tin:
327.3 KB
Tên tập tin:
8030460_AE00_KA_FLOWgate_Installation_en_V1-4_2025-03_EHS.pdf
-
-
-
Giải pháp ngành (SO)
Solutions for chemicals, petrochemicals and refineries
-
Giải pháp ngành (SO)
bản tiếng Anh - 01/2025New version available in EnglishEndress+Hauser offers a broad product portfolio of continuous gas analyzers using state-of-the-art technologies.
Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/01/2025
Cỡ tập tin:
3.1 MB
Tên tập tin:
8030415_CPR_en_V1-0_2025.01_EHS.pdf
-
-
-
Giải pháp ngành (SO)
Solutions for oil and gas industry
-
Giải pháp ngành (SO)
bản tiếng Anh - 01/2025New version available in EnglishEndress+Hauser offers the best solutions through a huge range of products and systems to measure and perform even under the most
rigorous operating conditions.Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/01/2025
Cỡ tập tin:
3.3 MB
Tên tập tin:
8030418_SO_Ol_and_Gas_en_V1-0_2025.01_EHS.pdf
-
-
-
Tài liệu về năng lực (CP)
FLOWSIC流量メータと流量測定機器
-
Tài liệu về năng lực (CP)
bản tiếng Nhật - 09/2025New version available in English精密な計量— 正確な請求とプロセス制御のために
Ngôn ngữ:
Tiếng Nhật
Phiên bản:
27/09/2025
Cỡ tập tin:
20.3 MB
Tên tập tin:
CP01584DJA_0225_Flow_meters_LowRes.pdf
-
-
-
Tài liệu về năng lực (CP)
FLOWSIC – flow meters and instruments
-
Tài liệu về năng lực (CP)
bản tiếng Anh - 05/2025New version available in EnglishPrecise quantity measurement for accurate billing and process control
Ngôn ngữ:
Tiếng Anh
Phiên bản:
13/05/2025
Cỡ tập tin:
3.1 MB
Tên tập tin:
8030079_CP_Flow_meters_en_V2-0_2025.05_EHS_WEB.pdf
-
Chọn theo đề xuất của chúng tôi
-
-- selected coding-- selected label99.999,00<%label%>
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Bản vẽ CAD Bản vẽ CAD
- Bản vẽ CAD
-
Giá cho mỗi chi tiết
-
<%range%><%price%>
-
- Các add-on tùy chọn