The Cerabar PMP55 digital pressure transmitter with metal diaphragm seal is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids. Suitable for high pressure as well as extreme process temperature applications from -70 up to +400°C (-94 to 750°F). Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511.
Single chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -70 to +400°C (-94 to +752°F)
Measuring ranges: -1/0 up to +400bar (-15/0 up to +6,000psi)
Accuracy: ±0.15%, "Platinum" ±0.075%
International explosion protection certificates, SIL, hygienic approvals, marine approvals
Lợi ích
Large variety of different process connections and membrane materials
New TempC Membrane minimizes influences of ambient and process temperature fluctuations
Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
Modular concept for easy replacement of display or electronics
Seamless and independent system integration (HART/PA/FF)
Video
IO-Link communication
IO-Link communication helps to digitalize your plant
Kemira, a global chemicals company, needs accurate monitoring of level and temperature for polymer manufacturing. They use instrumentation with Bluetooth for safe and easy access to process data.
Protolaunch uses Endress+Hauser flowmeters and level sensors at a rocket propulsion test facility in Buckinghamshire to demonstrate the performance of the propulsion systems and components.
Torishima designs and builds large cooling water systems for customers in the Middle East, relying on Endress+Hauser instrumentation for the quality and performance of the products.
Silicone oil, Inert oil, Vegetable oil, High temperature oil, Low temperature oil,
Material housing
Die-cast aluminum, AISI 316L
Communication
4...20 mA 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, UK Ex
Safety approvals
SIL
Design approvals
EN10204-3.1 NACE MR0103
Hygienic approvals
CoC ASME-BPE 3A, EHEDG
Marine approvals
GL/ ABS/ LR/ BV/ DNV
Specialities
TempC Membrane
Successor
PMP51B
Measuring principle
Absolute and gauge pressure
Characteristic / Application
Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm and diaphragm seal.
Supply / Communication
4 ..20 mA HART: 11,5...45 V DC Ex ia: 11,5...30 V DC PROFIBUS PA FOUNDATION Fieldbus
Accuracy
Standard 0.15% Platinum 0.075%
Long term stability
< 0,1% von URL/ year 0,2% of URL/ 5 years 0,25% of URL/ 10 years
Ambient temperature
-40°C...85°C (-40°F...185°F)
Process temperature
-70°C…400°C (-94°F…752°F)
Process pressure / max. overpressure limit
600 bar (9000 psi)
Pressure measuring range
1 bar...400 bar (15 psi...6000 psi)
Main wetted parts
316L AlloyC Montel Tantal Rhodium
Process connection
Diaphragm seal Flanges (DIN, ASME, JIS) Tri-Clamp ISO2852 Hygienic connections
Max. measurement distance
4000m (13.123ft) H2O
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus IO-Link
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI
Safety approvals
SIL
Design approvals
EN 10204-3.1 NACE MR0175, MR0103 AD2000
Hygienic approvals
3A, EHEDG CoC ASME-BPE
Marine approval
GL/ ABS/ LR/ BV/ DNV
Options
local display
Successor
PMP51B
Application limits
Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure
Cerabar M / Deltabar M / Deltapilot M, Operating Instructions
FOUNDATION Fieldbus
Hướng dẫn vận hành (BA)
bản tiếng Anh - 08/2024
New version available in English
Cerabar M PMC51, PMP51, PMP55 Pressure transmitter Deltabar M PMD55 Differential pressure transmitter Deltapilot M FMB50 Hyd rostatic pressure transmitter
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Chúng tôi sử dụng cookie để nâng cao trải nghiệm duyệt web của bạn, thu thập số liệu thống kê để tối ưu hóa chức năng của trang web và cung cấp nội dung hoặc quảng cáo phù hợp.
Bằng cách chọn "Chấp nhận tất cả", bạn đồng ý với việc sử dụng cookie của chúng tôi.
Để biết thêm chi tiết, vui lòng xem lại Chính sách cookie của chúng tôi.