©Endress+Hauser
Proline Prosonic Flow 91W for water and wastewater applications
Predecessor
Prosonic Flow Clamp On 90W
Successor
9W4BA0
Ultrasonic transit time flowmeter
Clamp-on version.
Application: Bidirectional flow
measurement for water + wastewater and
process water and hydropower plants.
Direct mounting.
Maintenance-free installation.
Corrosion-resistant transmitter version.
4-line display, touch control.
:: Clamp-on device for water +
wastewater with web server.
:: With Heartbeat Technology and short
inlet run thanks to FlowDC.
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Product headline
Device with automatic frequency scan for maximum measuring performance and cost-effective transmitter. Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater.
Sensor features
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Process transparency – diagnostic capability. Medium temperature: –20 to +80 °C (-4 to +176 °F). Degree of protection IP68 (Type 6P enclosure) for pipes under water. Shock and vibration resistance according to IEC 68-2-6.
Transmitter features
Economical transmitter – designed for easy applications. Fast and reliable commissioning – Quick Setup menu for installation. Automatic recovery of data for servicing. Aluminium field transmitter housing. 2-line display with push buttons. HART.
Nominal diameter range
Single channel, 1 or 2 paths : DN15 to 2000 (1/2 to 80")
Wetted materials
Clamp on system: Sensor holder 1.4308/CF-8 Sensor housing 1.4301/304 Strapping bands 1.4301/304
Measured variables
Volume flow, sound velocity, flow velocity, signal strength, totalizer
Max. measurement error
Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to 200 ±2% o.r. above DN200
Measuring range
0.3 to 10 m/s (1 to 33 ft/s)
Medium temperature range
-20 to +80°C (-4 to +176 °F) 0 to +130°C (32 to +265 °F) option
Ambient temperature range
-20 to +60 °C (-4 to +140 °F)
Transmitter housing material
Degree of protection
IP67, type 4X for transmitter IP67 type 4X for sensors IP68 type 6P for sensors (option). IP67 NEMA 4X
Display/Operation
2 lines backlit display with 3 push button
Outputs
1x 4-20 mA HART (active) 1x Pulse/frequency/switch output (passive)
Power supply
AC 85 to 250 V 20 to 28 V DC 11 to 40 V
Hazardous area approvals
Non hazardous area FM, CSA
Other approvals and certificates
Flowmeter verification for DN15, 25, 40, 50 & 100 only EAC marking
Metrological approvals and certificates
Flowmeter verification for DN15, 25, 40, 50 & 100 only
Most downloaded
Prosonic Flow 91
Operating Instructions
English version - 12/2023
Ultrasonic Flow Measuring System
Flow rate measuring for
standard applications with
drinking water, wastewater and
process water
(incl. Description of Device Functions)
EN
DE ES FR IT JA PL RU
More
06/12/2023
19/08/2011
01/02/2010
01/04/2006
Language:
English
Version:
06/12/2023
File size:
5.4 MB
File name:
BA00100DEN_1423.pdf
Proline Prosonic Flow 91W
Brief Operating Instructions
English version - 02/2012
Ultrasonic flow measuring system
EN
DE ES FI FR IT PT RU SV ZH
More
13/02/2012
19/08/2011
26/04/2010
Language:
English
Version:
13/02/2012
File size:
976.4 KB
File name:
KA00049DEN_1412.pdf
47 documents
Proline Prosonic 91W
Technical Information
Ultrasonic Flow Measuring System Flowrate measurement for standard applications with drinking water and process water.
EN
Bulgarian German Spanish French Italian Japanese Polish Chinese
Select other language
06/12/2023
19/08/2011
01/02/2010
Language:
English
Version:
06/12/2023
File size:
1.8 MB
File name:
TI00105DEN_1423.pdf
Prosonic Flow
90U, 90W, 91W, 93C, 93U, 93W
Technical
Information (SI units)
Ultrasonic Flow Measuring System Volume Flow Measurement for Standard Applications with Water, Wastewater and Process Water
EN
German Spanish French Italian Japanese Polish Portuguese Russian
Select other language
01/04/2006
01/05/2005
15/10/2003
01/12/2002
Language:
English
Version:
01/04/2006
File size:
1.4 MB
File name:
TI057DEN.pdf
Prosonic Flow 91
Operating Instructions
Ultrasonic Flow Measuring System Flow rate measuring for standard applications with drinking water, wastewater and process water (incl. Description of Device Functions)
EN
German Spanish French Italian Japanese Polish Russian
Select other language
06/12/2023
19/08/2011
01/02/2010
01/04/2006
Language:
English
Version:
06/12/2023
File size:
5.4 MB
File name:
BA00100DEN_1423.pdf
Proline Prosonic Flow 90, 91, 93
Sonderdokumentation / Special
Documentation
Montageanleitung für die Verbindung Sensoren / Messumformer bei Verwendung von flexiblen Kabelschutzrohren Mounting instruc tions for the sensor / transmitter connection using flxible conduit
EN
German
Select other language
01/11/2006
Language:
English
Version:
01/11/2006
File size:
228.6 KB
File name:
KA015Da2.pdf
Proline Prosonic Flow 91W
Brief Operating Instructions
Ultrasonic flow measuring system
EN
German Spanish Finnish French Italian Portuguese Russian Swedish Chinese
Select other language
13/02/2012
19/08/2011
26/04/2010
Language:
English
Version:
13/02/2012
File size:
976.4 KB
File name:
KA00049DEN_1412.pdf
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE ,8CM, 90, 91, 92, 93, 65, 72, 73
EN
German
Select other language
15/10/2024
01/10/2018
28/06/2012
Language:
English
Version:
15/10/2024
File size:
797.3 KB
File name:
EA00098DA2_1624-00.pdf
Replacing T-DAT
Installation Instructions
Promag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass DCI 8DF, Prosonic Flow 91, 93, t-mass 65
EN
German
Select other language
15/11/2018
21/11/2011
Language:
English
Version:
15/11/2018
File size:
481.6 KB
File name:
EA00072DA2_1418.pdf
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
EN
German
Select other language
01/03/2018
28/11/2013
25/04/2013
Language:
English
Version:
01/03/2018
File size:
139.5 KB
File name:
EA01051DA2_0318.pdf
Replacing transmitter parts
Installation Instructions
Promag 10, Prosonic Flow 91 W
EN
German
Select other language
01/04/2019
17/11/2011
Language:
English
Version:
01/04/2019
File size:
558.9 KB
File name:
EA00040DA2_1419.pdf
EA Permanent Coupling Pad
Prosonic Flow 91W, 93P, W 400, P 500
EN
German
Select other language
01/03/2024
15/12/2021
01/08/2021
16/09/2019
Language:
English
Version:
01/03/2024
File size:
609.4 KB
File name:
EA01256DA2_0423-00.pdf
Search spare parts by number in drawing
26 spare parts & accessories
26 spare parts
26 accessories
Kit Main-PCB 91W 85-250VAC
Drawing number
Order code
A
71138304
Kit Main-PCB 91W 20-28VAC 11-40VDC
Drawing number
Order code
A
71138309
Kit 10 fuses 1.0 A/250 slow
Drawing number
Order code
3
50104749
Kit 10 fuses 1.6 A/250 slow
Drawing number
Order code
3
50104750
Kit display 10/91W with keyboard
Drawing number
Order code
B
50104745
Kit T-DAT Transmitter Data Chip
Drawing number
Order code
2
50094004
Kit Ground terminal/Cover clamp
Drawing number
Order code
8
50097147
Kit Terminal Block 10/1YH/91W
Drawing number
Order code
1
50108138
Kit cover 10/91W with window
Drawing number
Order code
5
50104746
Kit cover 10/1YH/91W blind version
Drawing number
Order code
6
50104747
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
Drawing number
Order code
9
50098041
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
Drawing number
Order code
9
50098042
Kit 10 cable glands M20x1,5 grey
Drawing number
Order code
9
50103658
Kit PCB/Display carrier 10/91W
Drawing number
Order code
4
50104748
Kit cable glands Wall holding 91W
Drawing number
Order code
11
71022832
Kit Wall holding Prosonic 91W cpl.
Drawing number
Order code
10
71022835
Kit housing gasket 91W field housing
Drawing number
Order code
7
71023273
Prosonic Flow W, flow sensor set
Prosonic Flow 91/93/93T,sensor cable set
Prosonic Flow W/P, sensor holder set
Prosonic Flow W/P, install.set Clamp On
Prosonic Flow W/P, install.set Clamp On
Prosonic Flow W/P, install.set Clamp On
Prosonic Flow 91/93 W/P, conduit adapter
Coupling medium, Prosonic Flow
Transmitter 91/90/93, Mounting set