Liquiphant FTL62 - the coated sensor for aggressive media
A level switch for aggressive and pumpable liquids
Liquiphant FTL62 has a strong focus on specific applications with aggressive liquids and simplicity with easy proof testing, reliability and safety (SIL) with compliance to IEC 61508, API 2350 and WHG. The vibronic device is determined for a safe and active measuring technology in aggressive liquids and want a reliable and proven point level detection for tank overfill prevention and pump dry run protection. The FTL62 is easy to use, has a digital connection and gives a real-time data at hand.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
This product is not available in this market.
-
Specs at a glance
-
Process temperature
Process temperature
-
Process pressure absolute / max. overpressure limit
Vacuum...40 bar
Vacuum...580 psi -
Min. density of medium
Min. density of medium
-
Quick selection
Individual configuration
-
Benefits
Universal measuring principle for limit detection – proven vibronic technology
-
Developed according IEC 61508 for highest safety – SIL2/3 applications (3rd party approved)
Periodic proof testing is quickly and simple organized with guided wizards via the...
-
Field of application
Point level switch with extension tube for pumpable liquids
Coated sensor for aggressive media: ECTFE (Halar), PFA (EdlonTM, Ruby Red, conductive), Enamel
Process temperature: -60 °C to +150°C
Process pressure: -1 to +40bar
Ambient temperature: -60...
Documents / Manuals / Software
-
Density Computer FML621 with
Liquiphant FTL62 Density
Vibronic
Technical Information (TI) -
Liquiphant FTL62
Vibronic
Technical Information (TI) -
Liquiphant FTL62
Vibronic
Operating Instruction (BA) -
Liquiphant FTL62 Density
Vibronic
Operating Instruction (BA) -
Liquiphant FTL62
Vibronic
Short Instruction (KA)11/20English -
Liquiphant FTL62 Density
Vibronic
Short Instruction (KA)11/20English -
Dummy plug M20×1.5, dummy plug NPT½
Liquiphant, Gammapilot,
Cerabar, Deltabar
Prothermo NMT81Installation Instructions (EA) -
Cable gland M20x1.5
Liquiphant, Gammapilot
Cerabar, DeltabarInstallation Instructions (EA) -
Cover, cover seal
Liquiphant FTL41, FTL51B, FTL62, FTL64
Gammapilot FMG50
Cerabar PMC51B, PMP51B, PMC71B, PMP71B
Deltabar PMD55B, PMD75B, PMD78BInstallation Instructions (EA) -
Terminal module, 4 to 20 mA
Gammapilot FMG50, Prothermo NMT81
Cerabar PMC71B, PMP71B
Deltabar PMD75B, PMD78B
Liquiphant FTL51B, FTL62, FTL64Installation Instructions (EA) -
Ground terminal
Liquiphant, Gammapilot,
Cerabar, DeltabarInstallation Instructions (EA) -
LED module VU120
Liquiphant FTL51B, FTL62, FTL64
Installation Instructions (EA) -
Bluetooth module VU121
Liquiphant FTL51B, FTL62, FTL64
Installation Instructions (EA) -
M12 plug (housing side)
Liquiphant, Gammapilot,
Cerabar, DeltabarInstallation Instructions (EA) -
Electronic insert FEL6x
Liquiphant FTL51B, FTL62, FTL64
Installation Instructions (EA) -
Liquiphant FTL62
ATEX:
II 1/2 G Ex ia IIC/IIB T6...T1 Ga/Gb
II 2 G Ex ia IIC/IIB T6...T1 Gb
II 1/2 D Ex ia IIIC Txxx°C Da/Db
II 2 D Ex ia IIIC Txxx°C Db
IECEx:
Ex ia IIC/IIB T6...T1 Ga/Gb
Ex ia IIC/IIB T6...T1 Gb
Ex ia IIIC Txxx°C Da/Db
Ex ia IIIC Txxx°C DbEx Safety Instructions (XA) -
Liquiphant FTL62
ATEX:
II 1/2 G Ex ia IIC/IIB T6...T1 Ga/Gb
II 2 G Ex ia IIC/IIB T6...T1 Gb
IECEx:
Ex ia IIC/IIB T6...T1 Ga/Gb
Ex ia IIC/IIB T6...T1 GbEx Safety Instructions (XA) -
Liquiphant FTL62
ATEX:
II 1/2 G Ex db eb IIC/IIB T6...T1 Ga/Gb
II 2 G Ex db eb IIC/IIB T6...T1 Gb
IECEx:
Ex db eb IIC/IIB T6...T1 Ga/Gb
Ex db eb IIC/IIB T6...T1 GbEx Safety Instructions (XA) -
Liquiphant FTL62
ATEX:
II 3 G Ex ec IIC/IIB T6...T1 Gc
II 3 G Ex ec nC IIC/IIB T6...T1 Gc
II 3 D Ex tc IIIC Txxx°C Dc
IECEx:
Ex ec IIC/IIB T6...T1 Gc
Ex ec nC IIC/IIB T6...T1 Gc
Ex tc IIIC Txxx°C DcEx Safety Instructions (XA) -
Liquiphant FTL62
ATEX:
II 1/2 G Ex db IIC/IIB T6...T1 Ga/Gb
II 2 G Ex db IIC/IIB T6...T1 Gb
II 1/2 D Ex ta/tb IIIC Txxx°C Da/Db
II 2 D Ex tb IIIC Txxx°C Db
IECEx:
Ex db IIC/IIB T6...T1 Ga/Gb
Ex db IIC/IIB T6...T1 Gb
Ex ta/tb IIIC Txxx°C Da/Db
Ex tb IIIC Txxx°C DbEx Safety Instructions (XA) -
Liquiphant FTL62
ATEX:
II 1/2 G Ex db IIC/IIB T6...T1 Ga/Gb
II 2 G Ex db IIC/IIB T6...T1 Gb
IECEx:
Ex db IIC/IIB T6...T1 Ga/Gb
Ex db IIC/IIB T6...T1 GbEx Safety Instructions (XA) -
Bluetooth® module VU121
Suitable for Liquiphant FTL51B, FTL62, FTL64
Certified according to:
ATEX/IECEx:
Ex ia, Ex db, Ex db eb, Ex ec,
Ex ta/tb, Ex tb, Ex tc
EPL:
Ga, Ga/Gb, Gb, Gc, Da/Db, Db, DcEx Safety Instructions (XA) -
Adapter/cable gland
Level measurement, pressure measurement
Special Documentation (SD) -
Bluetooth® module VU121
Remote operation via Bluetooth® wireless technology
Special Documentation (SD) -
Liquiphant FTL51B, FTL62, FTL64
Application package
Heartbeat Verification + MonitoringSpecial Documentation (SD) -
Weather protection cover
Level measurement, pressure measurement
Special Documentation (SD) -
M12 socket
Accessories for Liquipoint, Liquitrend, Liquiphant, Ceraphant, Cerabar,
Deltabar, GammapilotSpecial Documentation (SD) -
Liquiphant FTL62 Density and Density Computer FML621
Vibronic
Special Documentation (SD) -
Cable gland M20 Ex d
for the Japanese market
Special Documentation (SD) -
Liquiphant FTL62
with electronic insert FEL68
Vibronic
Functional Safety (FY)09/20English -
Liquiphant FTL62
with electronic insert FEL64, FEL64DC
Vibronic
Functional Safety (FY)09/20English -
Liquiphant FTL62
with electronic insert FEL62
Vibronic
Functional Safety (FY)09/20English -
Liquiphant FTL62
with electronic insert FEL61
Vibronic
Functional Safety (FY)09/20English -
Liquiphant FTL62
with electronic insert FEL67
Vibronic
Functional Safety (FY)09/20English -
The challenge and solution, inventory Management of NGLs in 1.3m x 500m
horizontal
vessels
White Paper - As presented at the Canadian School of hydrocarbon
measurement
calgary 2018Case Studies (CS)05/18English -
Innovation brochure Liquiphant FTL62
Liquiphant FTL62 –
the specialist for aggressive liquids ensures plant safety and efficiencyInnovations (IN)01/21English -
Liquiphant
Product Code: FTL51B-, FTL62-, FTL64-
Declaration Number: EC_00750_02.19EU DeclarationGerman , English , fr -
Liquiphant
Product Code: FTL51B-, FTL62-, FTL64-
Declaration Number: EC_00751_02.19EU DeclarationGerman , English , fr -
Liquiphant
Product Code: FTL41-, FTL51B-, FTL62-, FTL64-
Declaration Number: EC_00721_02.18EU DeclarationGerman , English , fr -
Liquiphant
Product Code: FTL51B-, FTL62-, FTL64-
Declaration Number: EC_00724_02.18EU DeclarationGerman , English , fr -
Liquiphant
Product Code: FTL41-, FTL51B-, FTL62-, FTL64-
Declaration Number: EC_00749_02.19EU DeclarationGerman , English , fr -
Liquiphant, Nivotester
Product Code: FTL325N-, FTL51B-, FTL62-, FTL64-
Declaration Number: SIL_00361_01.20SIL DeclarationEnglish -
Liquiphant
Product Code: FTL62-
Declaration Number: SIL_00351_01.20SIL DeclarationEnglish -
Liquiphant
Product Code: FTL62-
Declaration Number: SIL_00347_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325N-, FTL51B-, FTL62-, FTL64-
Declaration Number: SIL_00359_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325N-, FTL51B-, FTL62-, FTL64-
Declaration Number: SIL_00360_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325P-, FTL51B-, FTL62-, FTL64-
Declaration Number: SIL_00352_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325N-, FTL51B-, FTL62-, FTL64-
Declaration Number: SIL_00358_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325P-, FTL62-
Declaration Number: SIL_00355_01.20SIL DeclarationEnglish -
Liquiphant
Product Code: FTL62-
Declaration Number: SIL_00357_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325P-, FTL62-
Declaration Number: SIL_00353_01.20SIL DeclarationEnglish -
Liquiphant
Product Code: FTL62-
Declaration Number: SIL_00348_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325P-, FTL62-
Declaration Number: SIL_00356_01.20SIL DeclarationEnglish -
Liquiphant
Product Code: FTL62-
Declaration Number: SIL_00349_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325N-, FTL51B-, FTL62-, FTL64-
Declaration Number: SIL_00362_01.20SIL DeclarationEnglish -
Liquiphant
Product Code: FTL62-
Declaration Number: SIL_00350_01.20SIL DeclarationEnglish -
Liquiphant, Nivotester
Product Code: FTL325P-, FTL62-
Declaration Number: SIL_00354_01.20SIL DeclarationEnglish -
Liquiphant
Product Code: FTL41-, FTL51B-, FTL62-, FTL64-
Region/Country: International (IECEx)
Approval Agency: KIWA
Protection: Ex ec, Ex t, Ex ia, Ex d e, Ex dExplosion ProtectionEnglish -
Liquiphant
Product Code: FTL51B-, FTL62-, FTL64-
Region/Country: Europe (ATEX)
Approval Agency: Endress+Hauser
Category: II 3 D, II 3 G
Protection: , Ex ecExplosion ProtectionGerman , English , fr -
Liquiphant
Product Code: FTL41-, FTL51B-, FTL62-, FTL64-
Region/Country: Europe (ATEX)
Approval Agency: KIWA
Category: II 1 G, II 1/2 G, II 1/2 D, II 2 G, II 2 D
Protection: Ex t, Ex ia, Ex d e, Ex dExplosion ProtectionEnglish -
Liquiphant
Product Code: FTL41-, FTL51B-, FTL62-, FTL64-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.11-590Overfill PreventionGerman -
Liquiphant
Product Code: FTL41-, FTL51B-, FTL62-, FTL64-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.40-591Overfill PreventionGerman -
Micropilot, Micropilot S, Minicap, Nivector, Prosonic M, Prosonic S, Prosonic T, Pumpenschutz, Solicap M, Solicap S, Soliphant M, Soliphant T, SYSTEM, Doppelstabsonde, Dreistabsonde, Einstabsonde, Levelflex, Liquicap M, Liquicap T, Liquiphant, Liquiphant FailSafe, Liquiphant M, Liquiphant S, Liquipoint, Liquipoint T, LIQUITREND
Product Code: FTL51C-, FTL51B-, FTL51-, FTL50H-, FTL50-, FTL41-, FTL33-, FTL31-, FTI77-, FTI56-, FTI55-, FTI52-, FTI51-, FTI26-, FTC968Z-, FTC262-, FTC260-, FMU44-, FMU43-, FTL51H-, FTL62-, FTL64-, FTL70-, FTL71-, FTL80-, FTL81-, FTL85-, FTM20-, FTM21-, FTM50-, FTM51-, FTM52-, FTW23-, FTW31-, FTW32-, FTW33-, NMR81-, NMR84-, QMW43-, FMU42-, 11362Z-, 11363Z-, 11371-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMU41-, FMU40-, FMU30-, FMR67-, FMR62-, FMR60-, FMR57-, FMR56-, FMR540-, FMR54-, FMR532-, FMR53-, FMR52-, FMR51-, FMR50-, FMR20-, FMR10-, FMP57-, FMP56-
Approval Agency: TÜVPressure EquipmentGerman , English -
Liquiphant
Product Code: FTL51B-, FTL62-, FTL64-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)German , English -
Liquiphant
Product Code: FTL41-, FTL51B-, FTL62-, FTL64-
Region/Country: International
Approval Agency: LRMarineGerman , English -
Liquiphant
Region/Country:
Heartbeat TechnologyEnglish
Accessories / Spare parts
-
-
Order code
Spare parts list in preparation.
-