Proline Promag H 100
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag H 100 ©Endress+Hauser
Electromagnetic flowmeter - Proline Promag H 100 ©Endress+Hauser

Proline Promag H 100 for the food & beverages and life sciences industries

The Electromagnetic Flow Measuring Principle

Introduction of Proline Web server

The specialist for hygienic applications with an ultra-compact transmitter

Promag H is the preferred sensor for hygienic applications with highest requirements in the food and beverage and life sciences industries. The ultra-compact transmitter provides full performance on the smallest footprint and enables seamless system integration, making Promag H 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology ensures compliance and process safety at all times.

  • Benefits

    • Multivariable measurement for flow, temperature and conductivity

    • Flexible installation concept – numerous hygienic process connections

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • Space-saving transmitter – full...

  • Field of application

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity

    • Dedicated to demanding applications in the food and beverage as well as in life sciences industries

    Device properties

    • Integrated temperature...

Features and specifications

Back

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    The specialist for hygienic applications with an ultra‐compact transmitter. Multivariable
    measurement for flow, temperature and conductivity. Dedicated to demanding applications
    in the food and beverage as well as in life sciences industries.

  • Sensor features

    Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Integrated temperature measurement. Sensor housing made of stainless steel (3-A, EHEDG).

  • Transmitter features

    Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local
    operation without additional software and hardware – integrated web server. Integrated
    verification – Heartbeat Technology. Robust, ultra‐compact transmitter housing. High ingress protection: IP69.

  • Nominal diameter range

    DN 2 to 150 (¹⁄₁₂ to 6")

  • Wetted materials

    Liner: PFA

    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum

  • Measured variables

    Volume flow, temperature, conductivity, mass flow, corrected volume flow, corrected
    conductivity

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

    Volume flow (option) ±0.2 % o.r. ± 2 mm/s (0.08 in/s)

  • Measuring range

    0.06 dm³/min to 600 m³/h (0.015 to 2650 gal/min)

  • Max. process pressure

    PN 40, Class 150, 20K

  • Medium temperature range

    –20 to +150 °C (–4 to +302 °F)

  • Ambient temperature range

    –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    1.4301 (304), corrosion resistant

  • Transmitter housing material

    Compact: AlSi10Mg, coated
    Compact/ultra‐compact: 1.4301 (304)

  • Degree of protection

    Standard: IP66/67, type 4X enclosure
    Option: IP69

  • Display/Operation

    4‐line backlit display available (no local operation)
    Configuration via web browser and operating tools possible

  • Outputs

    4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)

  • Inputs

    None

  • Digital communication

    HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET

  • Power supply

    DC 20 to 30 V

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, INMETRO, EAC

  • Product safety

    CE, C-tick

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Verification: Heartbeat Technology complies with requirements for traceable verification according to ISO 9001:2008, chapter 7.6. a (TUV attestation)

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A, liner and seals acc. to FDA, cGMP

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, 100/300/400/500/500 digital

      Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Promag 400(C). (C) = generation index C.

  • 30
  • 50
    • Nr 50 Order code XPD0023-

      Display module, 4-wire, 100

      Usage: Promag 100, Promass 100, Prosonic Flow E 100.

  • 21
    • Nr 21 Order code 71185789

      Kit cover, compact, Alu

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.

    • Nr 21 Order code 71185790

      Kit cover, compact, stainless 1.4301

      Usage: Promass 100, Promag 100. Consists of: Cover stainless 1.4301. Gasket EPDM for cover.

    • Nr 21 Order code 71185793

      Kit cover,ultra compact,stainless 1.4301

      Usage: Promag/Promass 100, Promag/Promass 500 digital, sensor connection housing. Consists of: cover stainless 1.4301, gasket EPDM for cover.

  • 20
    • Nr 20 Order code 71266334

      Kit cover, sight glass, compact, Alu

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.

    • Nr 20 Order code 71266335

      Kit cover, sight glass, compact, 1.4301

      Usage: Promass 100, Promag 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.

    • Nr 20 Order code 71266337

      Kit cover,sight glass,ultra comp.,1.4301

      Usage: Promass 100, Promag 100. Consists of: Cover with sight glass stainless 1.4301. Gasket EPDM for cover.

  • 70
    • Nr 70 Order code 71211571

      Kit housing gaskets, compact, Alu

      Usage: Promag 100. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket EPDM for housing/sensor H. Gasket EPDM for housing/sensor E/P. O-Ring 29,87 x 1,78 HNBR for sensor connector.

    • Nr 70 Order code 71211572

      Kit housing gaskets, compact, stainless

      Usage: Promag 100. Consists of: Gasket EPDM for cover. Gasket EPDM for housing/sensor H. O-Ring 29,87 x 1,78 HNBR for sensor connector.

    • Nr 70 Order code 71211573

      Kit hous.gaskets,ultra compact,stainless

      Usage: Promag 100, Promag 500 digital, sensor connection housing. Consists of: gasket EPDM for cover, gasket EPDM for housing/sensor H, O-Ring 29,87x1,78 HNBR for sensor plug.

  • 15
    • Nr 15 Order code 50098036

      Kit 10 cable glands M20x1.5 Ex

    • Nr 15 Order code 71069285

      Kit 2 cable glands M20x1.5 INOX Ex

    • Nr 15 Order code 50098041

      Kit 10 ext. M20x1.5/G 1/2" (plug PVC)

    • Nr 15 Order code 71185802

      Kit 2 cable glands G1/2" INOX Ex

      Consists of: 2 x Extension M20x1,5/G1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug G1/2".

    • Nr 15 Order code 50098042

      Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)

    • Nr 15 Order code 71185800

      Kit 2 cable glands NPT1/2" INOX Ex

      Consists of: 2 x Extension M20x1,5/NPT1/2" 1.4404. 2 x O-Ring. 2 x Sealing plug NPT1/2".

  • 12
    • Nr 12 Order code 71276494

      Kit securing clamp, screw

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass 500 digital. Consists of: cover clamp, screw M4x16.

    • Order code DKH-

      Promag H, mounting set

      A mounting set includes 2 process connections incl. screws and the corresponding seals.

    • Order code DK5G-

      Promag H/Dosimag, seal set

    • Order code DK5HB-

      Promag H, distance disc

      The set includes 2 distance discs incl. screws and 2 seals. For dimensions refer to the technical documentation.

    • Order code DK5HM-

      Promag H, wall mounting set

    • Order code DK5HW-

      Promag H, weld in tool

    • Order code DK5HA-

      Promag H, adapter set

      Replacement of sensor Promag A or Promag H DN 25. The set includes 2 adapters and 2 seals. For dimensions refer to the technical documentation.

    • Order code DK5HR-

      Promag H, grounding ring

      The grounding ring set includes 2 grounding rings

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

Downloads

Please select your market / region