This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Electromagnetic
-
Product headline
The flowmeter for smallest flow rates with integrated solids content diagnostics. For demanding hygienic applications.
-
Sensor features
Flexible installation concept – numerous hygienic process connections. Energy‐saving flow measurement – no pressure loss due to cross‐section constriction. Maintenance‐free – no moving parts. Liner made of PFA. Sensor housing made of stainless steel (3-A, EHEDG).
-
Transmitter features
Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing. 4‐line backlit display with touch control. Two switch outputs.
-
Nominal diameter range
DN 2...150
1/12"...6" -
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum -
Max. measurement error
±0.25%
-
Measuring range
0...600 m3/h
-
Max. process pressure
PN16 to 40
-
Medium temperature range
-20...+150°C
(-4...+302°F) -
Degree of protection
IP 67 (NEMA 4x)
-
Display/Operation
Four line display with backlit
Touch control -
Outputs
4...20 mA
Pulse / frequency(active/passive)
Relais
Status -
Inputs
Status
Current input -
Digital communication
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Hazardous area approvals
ATEX, FM, CSA
-
Product safety
CE, C-tick, EAC marking
-
Hygienic approvals and certificates
3-A, EHEDG
-
-
Operating Instruction (BA)
Proline Promag 55
-
Operating Instruction (BA)
English version - 10/2009New version available in EnglishDescription of the device functions (Options and inputs). Additional
documentation for Proline Promag 55 Operating Instructions.EN 19/10/2009Language:
English
Version:
19/10/2009
File size:
1.5 MB
File name:
BA120DEN_1009.pdf
-
-
-
Operating Instruction (BA)
Proline Promag 55 PROFIBUS DP/PA Description of Device Functions
-
Operating Instruction (BA)
English version - 02/2011New version available in EnglishDescription of the device functions (Options and inputs). Additional
documentation for Proline Promag 55 PROFIBUS DP/PA Operating
Instructions.Language:
English
Version:
01/02/2011
File size:
1.1 MB
File name:
BA00125DEN_1311.pdf
-
-
-
Operating Instruction (BA)
Proline Promag 55 FOUNDATION Fieldbus Description of Device Functions
-
Operating Instruction (BA)
English version - 12/2009New version available in EnglishDescription of the device functions (Options and inputs). Additional
documentation for Proline Promag 55 FOUNDATION Fieldbus Operating
Instructions.Language:
English
Version:
01/12/2009
File size:
1.4 MB
File name:
BA127DEN_0709.pdf
-
-
-
Operating Instruction (BA)
Proline Promag 55
-
Operating Instruction (BA)
English version - 04/2021New version available in EnglishElectromagnetic Flow Measuring System for liquids with solids content or
inhomogeneous liquids. The description of the device functions are in a
separate documentation.Language:
English
Version:
27/04/2021
File size:
8 MB
File name:
BA00119DEN_1421.pdf
-
-
-
Operating Instruction (BA)
Proline Promag 55 FOUNDATION Fieldbus Operating Instructions
-
Operating Instruction (BA)
English version - 11/2017New version available in EnglishElectromagnetic Flow Measuring System for liquids with solids content or
inhomogeneous liquids. The description of the device functions are in a
separate documentation.Language:
English
Version:
27/11/2017
File size:
5.6 MB
File name:
BA00126DEN_1317.pdf
-
-
-
Operating Instruction (BA)
Proline Promag 55 PROFIBUS DP/PA Operating Instructions
-
Operating Instruction (BA)
English version - 11/2017New version available in EnglishElectromagnetic Flow Measuring System for liquids with solids content or
inhomogeneous liquids. The description of the device functions are in a
separate documentation.Language:
English
Version:
27/11/2017
File size:
8.7 MB
File name:
BA00124DEN_1417.pdf
-
-
-
Installation Instructions (EA)
Replacing T-DAT Promag 23, 53, 55, Promass 83, 84, 8WF, 8ME, Cubemass DCI 8CN, CNGmass DCI 8DF, Prosonic Flow 91, 93, t-mass 65
-
Installation Instructions (EA)
English version - 11/2011New version available in EnglishInstallation Instructions
EN 21/11/2011Language:
English
Version:
21/11/2011
File size:
1.1 MB
File name:
EA00072DA2_13.11.pdf
-
-
-
Installation Instructions (EA)
Replacing amplifier board Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, Cubemass DCI 8CN, CNGmass
DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN 15/11/2018Language:
English
Version:
15/11/2018
File size:
393.9 KB
File name:
EA00064DA2_1518.pdf
-
-
-
Installation Instructions (EA)
Replacing amplifier board for harsh environment (HE) Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromag 50, 53, 55, Promass 80, 83, 84, Cubemass DCI 8CN, CNGmass DCI 8DF
EN 15/11/2018Language:
English
Version:
15/11/2018
File size:
379.4 KB
File name:
EA00067DA2_1518.pdf
-
-
-
Manufacturer Information (MI)
PRM HART Package V1.05.00 Herstellerinformation beinhaltet PRM - Geräteliste, Freigabehinweise – HART
-
Manufacturer Information (MI)
German version - 04/2014New version available in EnglishHerstellerinformation für Anwender betreffend Softwareänderungen (in
Anlehnung an NAMUR-Empfehlung 53)
Neue Software Version: 1.05.00Language:
German
Version:
08/04/2014
File size:
403.8 KB
File name:
MI00099S_04_de_06.14.pdf
-