T14
Explosion proof Pt100 thermometer, US style

T14
Explosion proof Pt100 thermometer, US style ©Endress+Hauser

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

The robust thermometer is designed for use in demanding and safety relevant applications e.g. in Chemical, Oil & Gas and Energy industry. Harsh environments, corrosive substances and highest pressures can be handled by the use of robust thermowells and special materials. A optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. Flexible configuration possible.

Quick selection

Choose from our suggested options
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

or

Individual configuration

Continue your selection from all possible options
  • Benefits

    • FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications

    • Remove and install...

  • Field of application

    The T14 temperature sensor is a RTD assembly installed in Thermowell and designed for use in harsh environments and explosive areas, due to his FM and CSA approvals.
    The sensor is made up of a measurement probe with an insulated RTD element, sheath and...

Features and specifications

Back

Details

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    Explosion Proof US style

    modular temperature assembly

    for heavy duty applications

    flanged process connection

    with extension

    incl. thermowell

  • Terminal head

    TMT162 - aluminium - fieldhousing w. or w/o. display

    TMT162 - SS - fieldhousing w. or w/o. display

    TMT142 - aluminium - fieldhousing w. or w/o. display

    TA30H - aluminum - w. or w/o. display

  • Thermowell / protection tube

    bar stock (drilled)

  • Insert / probe

    mineral insulated (MI), flexible

    PTFE-insulated, rigid

  • Outer diameter protection tube / Insert

    7/8'' (22,23 mm)

    17/16'' (26,99 mm)

  • Max. immersion length on request

    up to 22.5" (571 mm)

    others on request

  • Material protection tube/ thermowell

    316/316L

    others on request

  • Optional coating

    Available on request

  • Process connection

    flange:

    ASME 1" 150 RF (B16.5)

    ASME 1" 300 RF (B16.5)

    ASME 1" 600 RF (B16.5)

    ASME 1" 900/1500 RF (B16.5)

    ASME 1,5" 150 RF (B16.5)

    ASME 1,5" 300 RF (B16.5)

    ASME 1,5" 600 RF (B16.5)

    ASME 1,5" 900/1500 RF (B16.5)

    ASME 2" 150 RF (B16.5)

    ASME 2" 300 RF (B16.5)

    ASME 2" 600 RF (B16.5)

    ASME 2" 900/1500 RF (B16.5)

  • Tip shape

    straight

    tapered

  • Surface roughness Ra

    32 μin. (0.80 μm)

  • Operating temperature range

    PT100 WW:

    -200 °C … 600 °C

    (-328 °F … 1.112 °F)

    PT100 TF:

    -50 °C … 200 °C

    (-58 °F … 392 °F)

  • Max. process pressure (static)

    at 20 °C: 500 bar (7.252 psi)

    depends on configuration

  • Accuracy

    class A acc. to IEC 60751

    class B acc. to IEC 60751

  • Response time

    depending on configuration

    63% rt = 20 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    FM XP

    CSA XP

    FM/CSA XP

    CSA GP

  • Certification

    SIL (transmitter only)

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification
  • F
    • Nr F Order code TMT142X-HA

      Housing cover blind, 316L Ex d, FM XP, CSA XP + O-ring

    • Nr F Order code TMT142X-HC

      Housing cover cpl. for display,316L Ex d FM XP, CSA XP, with O-ring

    • Nr F Order code TMT142X-HH

      Housing cover blind, Alu Ex d FM XP without O-ring CSA XP only as cover of terminal part

    • Nr F Order code TMT142X-HK

      Housing cover cpl. for display, Alu Ex d + O-ring

    • Nr F Order code TMT162X-HA

      Housing cover blind, 316L Exd ATEX Ex d, FM XP + O-ring CSA XP only as cover of terminal part

    • Nr F Order code TMT162X-HC

      Housing cover cpl. for display,Ex d,316L ATEX Ex d, FM XP, CSA XP + O-ring

    • Nr F Order code TMT162X-HH

      Housing cover blind, Alu Ex d FM XP + O-ring CSA XP only as cover of terminal part

    • Nr F Order code TMT162X-HK

      Housing cover cpl. for display,Alu Ex d + O-ring

    • Order code 51004948

      Cover latch spares kit field housing

      Screw, washer, spring washer

    • Order code 71044062

      Fixing kit cpl.TMT82/84/85 USA(american)

      2x screws, 1x sealing CDI-connector

    • Order code TMT162A-MA

      Mounting bracket,North American region standard model,stainl.steel wall/tube 2"

    • Order code TMT162A-MB

      Cable gland NPT1/2, North American region standard model,2xD0.5 cables

    • Order code TMT162A-MD

      Mounting bracket 2"tube V4A

    • Order code 71003600

      Temperature ceramic block 3 pole

    • Order code 71039736

      Temperature ceramic block 4 pole

    • Order code 71386275

      Integrable Surge Arrester Module

      for subsequent mounting in field transmitter. Ensure compatibility.

  • A
    • Nr A Order code TU111-

      RTD-Insert TU111, Gen.Purp. U.S.Style

      Spare part. Spring loaded. General purpose. Pt100 Sensor comply with IEC60751 standard, alpha=0.00385.

    • Nr A Order code TU211-

      RTD-Insert TU211, Approved U.S.Style

      Spare part. Flame path Nipple. Spring loaded. Pt100 Sensor comply with IEC60751 standard, alpha=0.00385.

  • E
    • Nr E Order code TU54-

      Thermowell TU54, Flanged U.S.Style

      Bar stock Thermowell, CRN Number. The Flange is welded on.

  • F
    • Nr F Order code TA30H-

      Terminal Head TA30H

      Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).

    • Order code TMT142E-

      Electronic TMT142E

    • Order code TMT162E-

      Electronic TMT162E

    • Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

Please select your market / region