Omnigrad M TR48
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Documents / Manuals / Software
-
Technical Information
omnigrad M TR47, TR48
Hygienic RTD temperature sensor assembly for weld-in installation
With or without thermowell and M.I. replaceable insert
PCP (4...20 mA), HART® or PROFIBUS-PA® electronic safetyTechnical Information (TI) -
TR1x, TR4x, TR88, TSC310, TST310, TR6x, TC1x, TC6x, TC88, TPC100,
TPR100, TM411, TM412, TR24
Thermometers and inserts
Ex iaIIC T1-T6 Ga, Ex iaD 20 T85-T450Ex Safety Instructions (XA) -
Omnigrad TR1x, TR4x, TR88, TR6x, TC1x, TC88, TEC420, TC6x
ATEX: II 1D, II 1/2D Ex ia IIIC or II 1G, II 1/2G Ex ia IIC IECEx: Ex
iaIIC
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
Mesure de température
Capteurs et transmetteurs pour les industries de process
Fields of Activities (FA)12/19fr -
温度测量
过程工业用温度传感器和温度变送器
Fields of Activities (FA)12/14Chinese -
Pomiar temperatury
Czujniki i przetworniki pomiarowe
do kontroli przemysłowych procesów technologicznychFields of Activities (FA)10/14Polish -
Измерение температуры
Датчики температуры и преобразователи для любых
отраслей промышленности.Fields of Activities (FA)06/13Russian -
Misura della temperatura
Termometri e trasmettitori
per l'industria di processoFields of Activities (FA)04/18Italian -
Catálogo medición temperatura
Termómetros y transmisores para la industria de proceso
Fields of Activities (FA)04/18Spanish -
Field of activities FA Temperature measurement
Thermometers and transmitters for the process industry
Fields of Activities (FA)03/13English -
Sıcaklık Ölçümü
Proses endüstrisi için termometreler ve transmiterler
Fields of Activities (FA)03/13Turkish -
Temperature measurement
Thermometers and transmitters for the process industry
Fields of Activities (FA)02/20English -
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Fields of Activities (FA)02/20German -
Измерение температуры
Ключевые особенности термометров Endress+Hauser для нефтегазовой отрасли
Competence Brochure (CP)08/11Russian -
Инженерные решения по термометрии
Специальные решения по термометрии для химической и
нефтеперерабатывающей промышленностиCompetence Brochure (CP)04/10Russian -
Process RTD General purpose, Process RTD Heavy duty, Process RTD Hygienic, Process TC General purpose
Product Code: TR15-, TR24-, TR25-, TR44-, TR45-, TR46-, TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TR10-, TR11-, TR12-, TR13-
Manufacturer DeclarationEnglish -
Product Family: Process RTD Hygienic
Product Code: TR48-, TR47-, TR46-, TR45-, TR44-
FDA DeclarationGerman , English , fr -
Process TC Heavy duty, Process TC General purpose, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Direct contact, Low cost RTD General purpose
Product Code: TM412-, TR10-, TR11-, TR12-, TR13-, TR15-, TR24-, TR25-, TR44-, TR45-, TR46-, TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TST40N-, TST41N-, TST434-, TM411-, TAF11-, TAF12D-, TAF12S-, TAF12T-, TAF16-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC420-, TM101-, TM111-, TM121-, TM131-, TM401-, TM402-
Declaration Number: EC_00136_02.16EU DeclarationGerman , English -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, ACCESSORIES: T_INSERTS, Process RTD Direct contact, Process RTD General purpose, Process RTD Heavy duty, Process RTD Hygienic
Product Code: TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TS101-, TS111-, TST310-, TST434-, TST602-, TR45-, TR44-, TR25-, TR24-, TR15-, TR13-, TR12-, TR11-, TR10-, TPR300-, TPR100-, TM411-, TM401-, TET300-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-DE.AZ01.B.01156MiscellaneousRussian
Accessories / Spare parts
-
-
Order code 71044061
Fixing kit cpl.TMT82/85/84 (european)
2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector
-
Order code 60018913
-
Order code 60018914
-
Order code 60018915
-
Order code 60020743
-
Order code 60020744
-
Order code 60020745
-
-
-
Nr A Order code TA20A-
Terminal Head TA20A
Product being phased out, limited availability. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100 oC; ATEX: +95 oC.
-
Nr A Order code TA20B-
Terminal Head TA20B
"Product being phased out, limited availability." Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black. Ambient temperature: max. +80 oC. Protection: IP65.
-
Nr A Order code TA20R-
Terminal Head TA20R
Product being phased out, limited availability. Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: AISI316L/1.4404. max temperature 100oC, ATEX: +95oC. Protection class IP66/IP67.
-
Nr A Order code TA21E-
Terminal Head TA21E
Retainer for terminal block or head transmitter. Cover: srewable. Material: aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65.
-
-
-
Nr C Order code TMT82-
iTEMP TMT82, Transmitter HART
2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.
-
Nr C Order code TMT84-
iTEMP TMT84, Transmitter PA
Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Nr C Order code TMT85-
iTEMP TMT85, Transmitter FF
Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Nr C Order code TID10-
Display for head transmitter TID10
to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.
-
-
-
Order code READWIN-
Readwin 2000 Operation + Read. software
-
Order code TXU10-
Configuration kit TXU10-
for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.
-
Order code FXA195-
Commubox FXA195
Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
-
-
-
Nr A Order code TA30A-
Terminal Head TA30A
Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Nr A Order code TA30D-
Terminal Head TA30D
Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
-
-
Nr C Order code TMT180-
iTEMP TMT180, Head Transmitter Pt100
Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Nr C Order code TMT181-
iTEMP TMT181, Head Transmitter PCP
Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Nr C Order code TMT182-
iTEMP TMT182, Head Transmitter HART
Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
-
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-