Hydrostatic
Level measurement
Deltapilot FMB70
Highest performance pressure sensor with the Contite cell for hydrostatic level measurement
The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
Standard 0,1%
Optional 0,075% -
Process temperature
-10°C...100°C
(14°F...212°F) -
Pressure measuring range
100mbar...10bar
(1.5psi...150psi) -
Process pressure absolute / max. overpressure limit
40 bar (600 psi)
-
Main wetted parts
Alloy C
316L -
Max. measurement distance
100m (328ft) H2O
-
Material process membrane
316L, AlloyC,
Gold-Rhodium -
Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
-
Quick selection
Individual configuration
-
Benefits
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation
Best batch-to-batch repeatability and long-term stability
...
-
Field of application
For level and/or pressure measurement.
Process connections: Threads, flanges and hygienic connections
Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
Accuracy: ±0.075%
International...
Documents / Manuals / Software
-
Weld-in adapter, process adapter and flanges
Level and pressure measurement
Technical Information (TI) -
Deltapilot S FMB70
Hydrostatic level measurement
Technical Information (TI) -
Cerabar S /Deltabar S /Deltapilot S
Description of device
functions
PROFIBUS PA
V04.01.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Deltapilot S FMB70
HART V02.30.zz
Operating Instructions
Pressure sensor with CONTITE measuring cell
Condensate-proofedOperating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S
HART V02.30.zz
Description of Instrument Functions
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S, Description of device functions
FOUNDATION Fieldbus
V 04.00.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Deltapilot S FMB70
PROFIBUS PA (V04.01.zz)
Operating Instructions
Pressure sensor with the CONTITE measuring cell
Condensate-resistant offering long-term stability; Communication
via PROFIBUS PAOperating Instruction (BA) -
Deltapilot S FMB70
FOUNDATION Fieldbus (V04.00.zz)
Operating Instructions
Pressure sensor with the CONTITE measuring cell
Condensate-resistant offering long-term stability; Communication
via FOUNDATION FieldbusOperating Instruction (BA) -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential
pressure transmitter
Deltapilot S - hydrostatic transmitterShort Instruction (KA)12/14German , English -
Exchange of sensor
Instalation Instruction
Deltapilot S FMB70
Short Instruction (KA)09/15German , English -
Deltapilot S FMB70
Brief Operating Instructions
Pressure sensor with the CONTITE measuring cell
condensate proofed and long-term stable;
Communication via
PROFIBUS PAShort Instruction (KA)04/17English -
Deltapilot S FMB70
Brief Operating Instructions
Pressure sensor with the CONTITE measuring cell
condensate proofed and long-term stable;
Communication via
FOUNDATION FieldbusShort Instruction (KA)04/17English -
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
Austausch der Elektronik am Cerabar S, Deltabar S, Deltapilot S
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
FMB70-, FMD72-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-,
PMP71-, PMP72-, PMP75-Short Instruction (KA)04/12German , English -
Exchange of sensor unit for separate version on Cerabar S PMP71 and
Deltapilot S FMB70
Exchange of sensor unit for separate version on Cerabar S PMP71 and
Deltapilot S FMB70Short Instruction (KA)04/12German , English -
Deltapilot S FMB70
HART
Brief Operating Instructions
Pressure sensor with CONTITE measuring cell
Condensate-proofedShort Instruction (KA)03/18English -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential pressure transmitter
Deltapilot S - hydrostatic level measurement
V02.30.zzShort Instruction (KA)02/18German , English -
Push button housing
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Installation Instructions
Gasket with metal ring for universal process adapter
Deltapilot M FMB50, Deltalpilot S FMB70, Deltabar FMD71, Deltabar S
FMD78, Cerabar M PMC51, Cerabar PMP23Installation Instructions (EA) -
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
Installation Instructions (EA) -
Terminal module
Installation Instructions
Cerabar S PMC71, PMP71, PMP75, Deltabar S FMD77, FMD78, PMD75, Deltabar
FMD71, FMD72, Deltapilot S FMB70Installation Instructions (EA) -
Harting plug HAN7D
Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
Installation Instructions (EA) -
Mounting set for housing T14/15
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Aluminum housing T15
Installation instruction
Deltabar S, Deltapilot S
Installation Instructions (EA) -
Display
Installation Instruction
Cerabar S, Deltabar, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Electronics
Installation Instructions
Cerabar S PMC71, PMP71, PMP75, Deltabar S FMD77, FMD78, PMD75, Deltabar
FMD71, FMD72, Deltapilot S FMB70Installation Instructions (EA) -
Aluminum housing T14
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
housing filter at housing T15
Installation instruction
Deltapilot S
Installation Instructions (EA) -
Housing filter VA
Cerabar, Deltabar, Deltapilot
Installation Instructions (EA) -
Feed-through and adapter for T15
Installation Instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Deltapilot S FMB70
NEPSI:
Ex ia IIC T4/T6 Ga/Gb
Safety Instructions
Hydrostatic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
II 3 G Ex nA IIC T6 Gc
EG 06 005 XEx Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
II 1 G Ex ia IIC T6/T4 Ga
II 1 D Ex ia IIIC T85°C Da
KEMA 04 ATEX 1100 XEx Safety Instructions (XA) -
Deltapilot S FMB70
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 1/2 D Ex ia IIIC T85°C Da/Db
Safety Instructions
Hydrostatic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
FM Control Drawing
960007651 C
ISEx Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T4 Ga/Gb
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltapilot S FMB70
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ga/Gb Ex ia IIC T6...T4
Ex ia IIIC T85 °C Da
Ex ia IIIC T85 °C DbEx Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
FM Control Drawing
XA01065P-B
NIEx Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
CSA Control Drawing
960007739 D
ISEx Safety Instructions (XA) -
Deltapilot S FMB70
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
IECEx:
Ex ia IIC T6...T4 Ga/Gb
Safety Instructions
Hydrostatic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
CSA Control Drawing
960007652 E
ISEx Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
FM Control Drawing
960007738 C
ISEx Safety Instructions (XA) -
Deltapilot S FMB70
II 1/2 D Ex ta/tb IIIC T85°C Da/Db
Safety Instructions
Hydrostatic Level Measurement
Ex Safety Instructions (XA) -
Deltapilot S FMB70
II 1/3 D Ex ta/tc IIIC T85°C Da/Dc
Safety Instructions
Hydrostatic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
Ex ia IIC T6...T4 Ga/Gb
IECEx KEM06.0011Ex Safety Instructions (XA) -
Safety Instructions
Deltapilot S FMB70
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ta IIIC T130 °C Da/Db (HART)
Ex ta IIIC T105 °C Da/Db (PA, FF)
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltapilot S FMB70
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ga/Gb Ex ia IIC T6...T4Ex Safety Instructions (XA) -
Deltapilot S FMB70
Z-65.11-426 (DIBt)
Certificate (ZE) -
RFID TAG
Certificate/Declaration of Conformity
ATEX:
II 2 G Ex ia IIC T6 Gb
II 2 D Ex ia IIIC T80°C Db;
IECEx:
Ex ia IIC T6 Gb
Ex ia IIIC T80°C Db
IECEx EPS 15.0042X; EPS 15 ATEX 1 1011 XCertificate (ZE) -
Deltapilot S FMB70
CSA
Drawing No.: 960007739 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltapilot S FMB70
CSA
Drawing No.: 960007652 -
Drawing Type: Control Drawing
HARTCertificate FM/CSA (ZD) -
Deltapilot S FMB70
CSA
Drawing No.: 960007652 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltapilot S FMB70
CSA
Drawing No.: 960007739 B
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltapilot S FMB70
CSA
Drawing No.: 960007739 -
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltapilot S FMB70
FM
Drawing No.: 960007651 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltapilot S FMB70
CSA
Drawing No.: 960007652 B
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltapilot S FMB70
FM
Drawing No.: 960007651 -
Drawing Type: Control Drawing
HARTCertificate FM/CSA (ZD) -
Deltapilot S FMB70
FM
Drawing No.: 960007738 -
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltapilot S FMB70
FM
Drawing No.: 960007738 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Application conditions for seals and plastics in the food sector
Level measurement, pressure measurement
Special Documentation
Application conditions for seals and plastics in the food sector
Special Documentation (SD) -
Deltapilot S FMB70
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Mechanical accessories for pressure measuring devices
Pressure measurement
Special Documentation (SD) -
Hygiene approvals
Level and pressure measuring devices
Special Documentation (SD) -
Mounting kit for new T14 housing
Mounting kit for new T14 housing
Special Documentation (SD) -
RFID TAG
Special Documentation
RFID TAG
Special DocumentationSpecial Documentation (SD) -
Functional Safety Manual
Deltapilot S FMB70
Level and Pressure Measurement
with Output Signal 4...20 mASpecial Documentation (SD) -
Deltapilot M/S, Waterpilot,
Cerabar M/S, Deltabar M/S
Einsatz im Trinkwasserbereich (NSF)
Use in the drinking water sector (NSF)
Utilisation dans le domaine de l’eau potable (NSF)
Special Documentation
Einsatz im Trinkwasserbereich (NSF)
Use in the drinking water sector (NSF)
Utilisation dans le domaine de l’eau potable (NSF)Special Documentation (SD) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Deltabar S: PMD75, FMD77, FMD78,
Cerabar S: PMC71, PMP71, PMP75,
Deltapilot S: FMB70
Manufacturer information for users regarding software updates (NE53)
Firmware V02.30.06, HART
Manufacturer Information (MI) -
Delapilot S: FMB70
Manufacturer information for users regarding software updates (NE53)
Softwareversion V02.20.00 HART
Manufacturer Information (MI) -
Deltapilot S: FMB70
Manufacturer information for users regarding software updates (NE53)
Software version V04.01.00 PA
Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Deltapilot S: FMB70
Manufacturer information for users regarding software updates (NE53)
Software version V02.11.00 HART
Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Deltapilot S: FMB70
Manufacturer information for users regarding software updates (NE53)
Software version V04.00.01 FF
Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Control Engineering marzec 2006
Akredytowana kalibracja przetworników ci&
347;nienia i ró
&
380;nicy ci&
347;nie&
324;Publications (PU)09/08Polish -
Napędy i Sterowanie styczeń 2007
Deltapilot S - unikatowa, sprawdzona technologia w hydrostatycznych
pomiarach poziomuPublications (PU)08/09Polish -
Nap&
281;dy i Sterowanie grudzie&
324; 2007
Nowa generacja zaawansowanych
rejestratorów Endress+Hauser Memograph MPublications (PU)08/09Polish -
Control Engineering marzec 2008
Pomiary przep&
322;ywu cieczy oraz g&
281;sto&
347;ci
cieczy metod&
261; Coriolisa w przemy&
347;le fa
rmaceutycznym, biotechnologicznym i kosmetycznym.Publications (PU)08/09Polish -
Napędy i Sterowanie styczeń 2006
Wykorzystanie pomiarów radiometrycznych na obiektach automatyki
przemys
łowejPublications (PU)08/09Polish -
Hermetyczny czujnik ciśnienia_PS_06_2010
Hermetyczny czujnik ciśnienia w aplikacjach higienicznych i
aseptycznychPublications (PU)04/12Polish -
Deltapilot S Evolution FMB70 i czujnik Contite- PS_06_2010
Hermetyczny czujnik ciśnienia w aplikacjach higienicznych i
aseptycznychPublications (PU)04/12Polish -
Nap&
281;dy i Sterowanie marzec 2008
Technologie czujników ci&
347;nienia Endress+HauserPublications (PU)03/08Polish -
Control Engineering marzec 2007
Pomiary ci&
347;nienia w przemy&
347;le spo
&
380;ywczym i farmacjiPublications (PU)03/07Polish -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)09/19Spanish -
压力测量
用于过程压力、差压、液位和流量测量的专业仪表
Fields of Activities (FA)09/15Chinese -
Basınç Ölçümü
Proses basıncı, fark basınç, seviye ve akış için güçlü enstrümanlar
Fields of Activities (FA)05/15Turkish -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des
solides en vracFields of Activities (FA)03/19fr -
Catálogo Medición de Presión
Instrumentos para la medición de presión, presión diferencial, nivel y
caudal de procesoFields of Activities (FA)03/17Spanish -
Druckmesstechnik
Leistungsfähige Messgeräte für Prozessdruck, Differenzdruck, Füllstand
und DurchflussFields of Activities (FA)03/17German -
Pressure measurement
American version: Powerful instruments for process pressure,
differential pressure, level
and flowFields of Activities (FA)03/17English -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17German -
Misura della pressione
Potenti strumenti per la misura della pressione di processo, pressione
differenziale,
livello e portataFields of Activities (FA)03/17Italian -
Mesure de pression
Appareils de mesure pour la pression de process, la pression
différentielle, le niveau et le débitFields of Activities (FA)03/17fr -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Pressure measurement
Powerful instruments for process pressure, differential pressure, level
and flowFields of Activities (FA)03/17English -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Pomiar ciśnienia
Potężna aparatura do pomiaru
ciśnienia procesowego, różnicy
ciśnień, poziomu i przepływuFields of Activities (FA)03/14Polish -
Cleaning in Place (CIP)
Portfolio of Endress+Hauser solutions
Competence Brochure (CP)05/15English -
Cleaning in Place (CIP)
Portfolio of Endress+Hauser solutions
Competence Brochure (CP)02/18English -
Continuous level measurement with tank spud connection delivered fast
and is less expensive
Deltapilot S FMB70 sensor offers Conite measuring cell, is immune to
condensation and provides long term stability.Case Studies (CS)06/10English -
Geräteintegration in eine Biodiesel-Anlage. Fallbeispiel Engineering
Integration verschiedener Messgeräte und Aktoren in der Campa
Biodiesel-Anlage, Ochsenfurt, Deutschland. Die Campa AG mit Sitz in Oc
hsenfurt bei
Würzburg zählt bei Produktion sowie im
internationalem Handel und Vertrieb zu
den innovativen Pionierunternehmender
jungen Biokraftstoffindustrie.Case Studies (CS)04/07German -
Device integration into a biodiesel plant
Case Study Engineering
Integration of various measurement devices and actuators at Campa
Biodiesel Plant, Ochsenfurt, GermanyCase Studies (CS)04/07English -
Deltapilot S, FMB 70
evel transmitter as pressure sensor for continuous, hydrostatic level
measurement for mounting on vesselsTender Text04/10English -
Deltapilot S, FMB70
Füllstand-Messwertaufnehmer, ausgeführt als Druckaufnehmer zur
kontinuierlichen, hydrostatischen Füllstandmessung zum Anbau an BehälterTender Text04/10German -
GSD Single, GSD_EH_PA_LE_Deltapilot_0x154F_V03_PALIB, 14.04.2014 (Level,
Deltapilot S, 0x154F)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.00.00Language neutral -
GSD Single, GSD_EH_PA_LE_DeltapilotS_0x154F_0x03_0x01_PALIB, 19.05.2014 (
Level, Deltapilot S, 0x154
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, AMS10_HART_LE_DeltapilotS_0x001A_0x17_0x02, 25.01.2018 (Level, Deltapilot S, 0x001A)
HART,
AMS Version: 10.0, 10.1, 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_DeltapilotS_0x100Bb_0x06_0x01_ITK5_01, 10.11.2016 (L
evel, Deltapilot S, 0x100B
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_LE_DeltapilotS_0x001A_0x16_0x03, 18.02.2015 (Level, Deltapilot S, 0x001A)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_DeltapilotS_0x100Bb_0x06_0x03_Honeywell, 12.05.2014
(Level, Deltapilot S, 0x10
FOUNDATION Fieldbus H1,
Experion Version: R210Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_DeltapilotS_0x154F_0x01_0x02, 07.01.2019 (Level, Deltapilot S, 0x154F)
PROFIBUS PA,
PDM Version: 6.0 SP5, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_DeltapilotS_0x100Bb_0x06_0x03_ITK5_20, 10.11.2016 (L
evel, Deltapilot S, 0x100B
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_LE_DeltapilotS_0x001A_0x16_0x03, 04.04.2017 (Level, Deltapilot S, 0x001A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_LE_DeltapilotS_0x100Bb_0x07_0x02, 12.05.2014 (Level, D
eltapilot S, 0x100Bb)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_LE_DeltapilotS_0x001A_0x16_0x03, 04.04.2017 (Level, Deltapilot S, 0x001A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS_FF_LE_DeltapilotS_0x100Bb_0x07_0x02, 07.04.2014 (Level, D
eltapilot S, 0x100Bb)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_LE_DeltapilotS_0x001A_0x17_0x02, 25.01.2018 (Level, Deltapilot S, 0x001A)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_LE_DeltapilotS_0x001A_0x15_0x02, 21.08.2019 (Level, Deltapilot S, 0x001A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_LE_DeltapilotS_0x001A_0x15_0x02, 31.03.2014 (Level,
Deltapilot S, 0x001A)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_DeltapilotS_0x001A_0x16_0x03, 28.05.2015 (Level, Deltapilot S)
HART,
PDM Version: 6.1, 8.1, 8.2 SP 1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_DeltapilotS_0x154F_0x03_0x02, 17.08.2015 (Level, De
ltapilot S)
PROFIBUS PA,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_LE_DeltapilotS_0x001A_0x17_0x02, 25.01.2018 (Level, Deltapilot S, 0x001A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_LE_DeltapilotS_0x001A_0x15_0x02, 21.08.2019 (Level, Deltapilot S, 0x001A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_DeltapilotS_0x001A_0x15_0x07, 25.02.2015 (Level, Deltapilot S, 0x001A)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_DeltapilotS_0x001A_0x17_0x01, 23.04.2018 (Level, Deltapilot S, 0x001A)
HART,
PDM Version: 6.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, DeltapilotS_FMB70_FF_V3_00_xx_DevRev6, 22.10.2020 (Level, Deltapilot S, 0x100Bb)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltapilotS_FMB70_FF_FW4_00_zz_Dev_Rev_7, 22.10.2020 (Level, Deltapilot S, 0x100Bb)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltapilotS_FMB70_PA_V4_01_zz, 21.10.2020 (Level, Deltapilot S, 0x154F)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, DeltapilotS_FMB70_PA_V4_00_zz, 28.10.2020 (Level, Deltapilot S, 0x154F)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltapilotS_FMB70_HART_FW2_20_zz_Dev_Rev_22, 27.10.2020 (Level, Deltapilot S, 0x001A)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Plant Resource Manager Version: R3.11, R3.12Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltapilotS_FMB70_HART_FW_2_30_zz_Dev_Rev_23, 27.10.2020 (Level, Deltapilot S, 0x001A)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltapilotS_FMB70_V02_10_xx, 23.10.2020 (Level, Deltapilot S, 0x001A)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Level_1_08_00, 22.07.2015 (Level)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Level_1_05_00, 29.05.2018 (Level)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.12Faceplate1.05.00Language neutral -
Faceplate Single, PRM_HART_LE_DeltapilotS_0x001A_0x16_0x03, 18.02.2015 (Level, Deltapilot S, 0x001A)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_LE_DeltapilotS_0x001A_0x17_0x02, 25.01.2018 (Level, Deltapilot S, 0x001A)
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_LE_DeltapilotS_0x100Bb_0x07_0x02, 07.04.2014 (Le
vel, Deltapilot S, 0x100Bb)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-, PMP71-, PMP72-, PMP75-
Declaration Number: HE_00729_01.17Manufacturer DeclarationGerman , English -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_02.19
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_01.19
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
Deltapilot S
Product Code: FMB70-
Declaration Number: HE_00188_03.15
Manufacturer Specification: Food hygiene, 10/2011, 1935/2004Manufacturer DeclarationGerman , English -
Deltapilot S
Product Code: FMB70-
Declaration Number: HE_00785_01.17
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
Deltapilot S
Product Code: FMB70-
Declaration Number: HE_01219_01.19Manufacturer DeclarationEnglish -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_03.19
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
Cerabar, Cerabar M, Cerabar S, Deltapilot M, Deltapilot S, Liquicap M
Product Code: FMB50-, FMB70-, FMI51-, FTI51-, PMC51-, PMC51B-, PMP23-, PMP55-, PMP75-
Declaration Number: HE_01222_02.20
Manufacturer Specification: 1935/2004Manufacturer DeclarationGerman , English -
Deltapilot S
Product Code: FMB70-
Declaration Number: HE_01209_01.19Manufacturer DeclarationEnglish -
Deltapilot S
Product Code: FMB70-
Declaration Number: HE_01221_01.20
Manufacturer Specification: Food hygieneManufacturer DeclarationEnglish -
Deltapilot S
Product Code: FMB70-
Declaration Number: HE_00188_02.15
Manufacturer Specification: Food hygiene, 10/2011, 1935/2004Manufacturer DeclarationGerman , English -
Deltapilot S
Product Code: FMB70-
Declaration Number: FDA_00225_01.19FDA DeclarationGerman , English -
Deltapilot S
Product Code: FMB70-
Declaration Number: FDA_00173_01.18FDA DeclarationGerman , English -
Cerabar M, Cerabar S, Deltapilot M, Deltapilot S, Liquiphant M
Product Code: PMP75-, PMP55-, PMP51-, FMB70-, FTL51H-, FTL50H-, PMC51-, FMB50-
Declaration Number: FDA_00073_04.15FDA DeclarationGerman , English -
Deltapilot S
Product Code: FMB70-
EU DeclarationGerman , English , fr -
Deltapilot S
Product Code: FMB70-
Declaration Number: EC_00197_03.16EU DeclarationGerman , English , fr -
Deltapilot S
Product Code: FMB70-
Declaration Number: EC_00555_03.17EU DeclarationGerman , English , fr -
Deltapilot S
Product Code: FMB70-
Declaration Number: SIL_00253_01.18SIL DeclarationEnglish -
Deltapilot S
Product Code: FMB70-
Region/Country: China
Approval Agency: ACMA
Approval Number: EC11014AMiscellaneousEnglish -
Waterpilot, Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PTP31B-, PTC31B-, PMP75-, PMP71B-, PMP71-, PMP55-, PMP51B-, PMP51-, PMP23-, PMP21-, PMP11-, PMD78B-, PMD75B-, PMD75-, PMD55B-, PMD55-, PMC71B-, PMC71-, PMC51B-, PMC51-, PMC21-, PMC11-, FMX21-, FMD78-, FMD77-, FMD72-, FMD71-, FMB70-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-DE.DE02.B.11894/20MiscellaneousRussian -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1,2/A,B,C,D,F,G/
Protection: DIP, IS, NIExplosion ProtectionEnglish -
Deltapilot M, Deltapilot S
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, FMB70-
Protection: Ex ia IIC T6...T2 Ga/Gb, Ex ia IIC T6...T2 Gb, Ex ia IIC T6...T3 Ga/Gb, Ex ia IIC T6...T3 Gb, Ex ia IIIC Txxx°C Da, Ex ia IIIC Txxx°C Da/Db, Ex ic IIC T6...T3 Gc, Ex ta IIIC Txxx°C Da/Db, Ex ta/tc IIIC Txxx°C Da/Dc, Ex ta/tb IIIC Txxx°C Da/DbExplosion ProtectionRussian -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country:
Approval Agency:
Protection: Ex ia, Ex taExplosion Protection -
Deltapilot S
Product Code: FMB70-
Region/Country: Europe (ATEX)
Approval Agency: Endress+Hauser
Category: II 3 G
Protection: Ex nA IIC T6 GcExplosion ProtectionGerman , English , fr -
Cerabar S, Deltabar S, Deltapilot S
Product Code: PMP75-, PMP71-, PMD75-, PMD70-, PMC71-, FMD78-, FMD77-, FMB70-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex iaExplosion ProtectionPortuguese -
Deltapilot S
Product Code: FMB70-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 1 D, II 1 G
Protection: Ex ia IIC T6 GaExplosion ProtectionEnglish -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Deltapilot S
Product Code: FMB70-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6Explosion ProtectionEnglish -
Deltapilot S
Product Code: FMB70-
Region/Country: China
Approval Agency: NEPSI
Category: GA/ GB
Protection: Ex ia IIC T6Explosion ProtectionEnglish , Chinese -
Cerabar S, Deltabar S, Deltapilot S
Product Code: PMP75-, PMP71-, PMD75-, PMC71-, FMD78-, FMD77-, FMB70-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 1/3 D, II 1/2 G, II 1/2 D, II 2 G
Protection: Ex ta/tb IIIC Txxx°C Da/Db, Ex ia IIIC Txxx°C Da/Db, Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Canada, USA
Approval Agency: CSA
Category: II,III/1/E,F,G, I,II,III/1/B,C,D,E,F T6, I,II,III/1/A,B,C,D,E,F,G T6, I/2/A,B,C,D
Protection: XP/IS, XP, NI, IS/NI/DIP, DIPExplosion ProtectionEnglish -
Deltapilot M, Deltapilot S
Product Code: FMB50-, FMB70-
Region/Country: EuropeHygienic EquipmentEnglish -
Waterpilot, Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Cerabar S, Cerabar M, Cerabar
Product Code: PMP71B-, PMP71-, PMP51B-, PMP51-, PMD75-, PMD55B-, PMD55-, PMC71B-, PMC71-, PMC51B-, PMC51-, FMX21-, FMX167-, FMD72-, FMD71-, FMB70-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Prosonic S, Nivector, Micropilot, LIQUITREND, Liquipoint, Liquiphant M, Liquicap M, Levelflex, Deltapilot S, Deltapilot M, Deltabar S, Deltabar, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Product Code: QMW43-, PTP33B-, PMP75-, PMP55-, PMP51-, PMP23-, PMC71-, PMC51-, FTW33-, FTW23-, FTL51H-, FTL50H-, FTL33-, FDU91F-, FMB50-, FMB70-, FMD71-, FMD72-, FMD78-, FMI51-, FMP52-, FMP53-, FMR52-, FMR62-, FTI26-, FTI51-
Region/Country: USA
Approval Agency: 3-A Sanitary StandardsHygienic EquipmentEnglish -
Deltapilot S
Product Code: FMB70-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.11-426Overfill PreventionGerman -
Product Family: Deltapilot S
Product Code: FMB70-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.02Fieldbus ConformanceEnglish -
Product Family: Deltapilot S
Product Code: FMB70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.01Fieldbus ConformanceEnglish -
Product Family: Deltapilot S
Product Code: FMB70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 07, DD-ITK 6.10Fieldbus ConformanceEnglish -
Product Family: Deltapilot S
Product Code: FMB70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.20Fieldbus ConformanceEnglish -
Deltapilot S
Product Code: FMB70-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Waterpilot, SYSTEM, Gammapilot M, Gammapilot, Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant T, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Product Code: PMC71B-, PMD55-, PMD75-, PMD75B-, PMD78B-, PMP11-, PMP21-, PMP23-, PMP51-, PMP51B-, PMP55-, PMP71-, PMP71B-, PMP75-, PTC31B-, PTP31B-, PTP33B-, FMB50-, FMB53-, FMB70-, FMD71-, FMD72-, FMD77-, FMD78-, FMG60-, FMX21-, FTG20-, NMS80-, NMS83-, PMC11-, PMC21-, PMC51-, PMC51B-, PMC71-
Approval Agency: TÜVPressure EquipmentGerman , English -
Liquiphant, Deltabar S, Cerabar S, Liquiphant M, Cerabar M, Deltapilot S, Liquipoint, Liquicap M, Liquiphant FailSafe, Ceraphant, Cerabar, Deltapilot M, Deltabar
Product Code: FTL33-, FMD78-, PMP75-, PMP51-, PMP55-, FMB70-, PMC51-, FTL51H-, FTL50H-, FTL51-, FMB50-, FMI52-, FTL50-, FTI52-, FTL81-, FMI51-, FTI51-, FTL31-, FTW23-, FTW33-, FTL80-, PTP33B-, PMP23-, FMD71-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Deltapilot S
Product Code: FMB70-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Deltapilot M, Deltapilot S, Waterpilot
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, FMB70-, FMX21-
Region/Country: Belarus
Approval Agency: BEL
Approval Number: 11776MetrologyRussian -
Deltapilot M, Deltapilot S, Waterpilot
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, FMB70-, FMX167-, FMX21-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6924MetrologyRussian -
Deltapilot M, Deltapilot S
Product Code: FMB70-, FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.30.004.A NO 38961/1MetrologyRussian -
Cerabar, Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)English -
Deltapilot M, Deltapilot S
Product Code: FMB50-, FMB52-, FMB53-, FMB70-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Deltapilot S
Product Code: FMB70-
Region/Country: International
Approval Agency: DNVGLMarineEnglish -
Deltapilot S
Product Code: FMB70-
Approval Agency: ABSMarineEnglish -
Deltapilot S
Product Code: FMB70-
Approval Agency: LRMarineEnglish
Accessories / Spare parts
-
-
Nr 12 Order code 52020440
Mounting set housing T14/T15 sensor
Consists of: 2x O-ring 45.69x2.62 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 12 Order code 71020596
Mounting set housing T17 / sensor
Consists of: 2x O-ring 45.62x69x2.62 EPDM. 1x profile gasket 51.4x57.2x1.6 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 13 Order code 52022418
Push button housing, PA/FF
Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 13 Order code 52024110
Push button housing, HART, version 2
Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.
-
-
-
Nr 15 Order code 52020760
Cable gland M20, gasket
Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020761
Cable entry G1/2, gasket, adapter
Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020762
Plug 2/7-pole, HAN7D, gasket
Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Nr 15 Order code 52020763
Plug 3-pole, M12, gasket
Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Order code 52006263
M12-female plug connector, cable side
M12 plug socket, cable side Self confectionery connection. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FTL31/FTL33, FTW23, FTW33,PMP11, PMP21, PMP51, PTC31B, PTP31B, QMW43.
-
Order code 71043576
Housing filter plastic T15, 3 pieces
Consists of: filter plug, Gore-Tex filter. Usage: housing T15, FMB70.
-
Order code 71111056
Housing filter VA,EPDM,F15/31/T14/17,1pc
Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Order code 71219639
Housing filter VA, VMQ, F15, T17, 1 pc.
Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
-
-
Nr 20 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 25 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 20 Order code 71002810
Cover T17 316L, sight glass, gasket
Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.
-
Nr 20 Order code 71002811
Cover T17 316L, sight glass PC, gasket
Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.
-
Nr 20 Order code 71245247
Cover T14/T15 Alu, sight glass, gasket
Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 21 Order code 52020429
Sealing EPDM, F30/31/34, T14/15, 5 pcs.
Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.
-
-
-
Order code 71290825
Ground terminal T14/T15/T17, F30/F31
Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 25 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 71026358
Electronics HART Ex, v2.10
4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026359
Electronics HART Ex, ext. p. b., v2.10
4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071824
Electronics PA, HW02.00, SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071825
Electronics PA, ext. p.b., HW02.00,SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071826
Electronics FF, HW2.00, SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71071827
Electronics FF, ext. p.b., HW2.00,SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71196092
Electronic HART Ex, v2.11
4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71196093
Electronics HART Ex, ext. p. b., v2.11
4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71214890
Electronics FF, ext. p.b.,HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71214892
Electronics FF, HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71224775
Electronics PA, HW02.00, SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71224776
Electronics PA, ext.p. b.,HW02.00,SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71263933
Electronics HART Ex, v2.20
4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71263934
Electronics HART Ex, ext. p. b., v2.20
4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71386147
Elektronics HART Ex, v2.30
4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71386153
Electronics HART Ex, ext. p. b., v2.30
4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
-
-
Nr 31 Order code 52027785
HistoROM / M-DAT, 16K
Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 31 Order code 52027785
HistoROM / M-DAT, 16K
Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 35 Order code 52020434
Terminal 3-pole, RFI, HART, TIIS
RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75, TIIS Ex ia.
-
Nr 35 Order code 52026605
Terminal 2-pole, RFI, PA, TIIS
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.
-
Nr 35 Order code 52027691
Terminal 2-pole, RFI, FF, Ex
RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028473
Terminal 3p., RFI, HART, OVP, TIIS
Overvoltage protection, RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028475
Terminal 2-pole, RFI, PA, OVP, Ex
Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028476
Terminal 2-pole, RFI, FF, OVP, Ex
Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71121574
Terminal 2-pole, RFI, PA, Ex
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.
-
Nr 35 Order code 71191892
Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd
RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71191894
Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd
Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 40 Order code 71002865
Display module VU340, Cbar/Dbar/Dpilot S
Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.
-
-
-
Order code 71043886
Cable PE, L=2m/80inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043888
Cable PE, L=5m/200inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043889
Cable PE, L=10m/400inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71070738
Cable FEP, L=5m/200inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 214880-0002
Weld-in adapter UNI D65, 316L
Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.
-
Order code 52002041
Weld-in adapter DRD DN50, 316L
Front-flush mounting of devices with DRD flange. Material: 316L. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.
-
Order code 52006262
Weld-in adapter UNI D85, 316L
Flush mount process connection. Core hole: 85mm. Material: 316L. Seal: silicone profile gasket. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52 PMC51, PMP23, PMP55, PMP75.
-
Order code 52010173
Weld-in adapter UNI D85, 316L, 3.1
Flush mount process connection. Core hole: 85mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.
-
Order code 52010174
Weld-in adapter UNI D65, 316L, 3.1
Flush mount process connection. Core hole: 65mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.
-
Order code 52011899
Weld-in adapter DRD DN50, 316L, 3.1
Flush mount process connection of devices with DRD flange. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.
-
Order code 52024469
Weld-in adapter G1-1/2, 316L
Mounting process connection G1-1/2. Material: 316L. Correct installation only with dummy. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.
-
Order code 52024470
Weld-in adapter G1-1/2, 316L, 3.1
Mounting process connection G1-1/2. Material: 316L. Inspection cert. EN10204-3.1 material. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP52, PMP71/PMP75.
-
Order code 916743-0000
Weld-in adapter DRD DN50, 304
Flush mount process connection. Material: 304. Seal: PTFE flat. FDA compliant. Usage: Flush mount FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMP51, PMP55, PMC71, PMP75, FMB50, FMB70, FMD78.
-
-
-
Nr 50 Order code FMB70X-
-
-
-
Order code 52024228
Flat seal 50x65x1 PTFE, FDA, 5 pieces
Fit to weld-in adapter DRD-DN50. Flush mount FTL50H/FTL51H, PMC51, pressure device.
-
-
-
Nr 57 Order code 52023572
Profile gasket silicone, 5 pieces
Process gasket universal process adapt. FDA listed. Usage: FMB50, FMB70, FMI51/FMI52, FTI51/FTI52/FTI55, PMC51.
-
Nr 57 Order code 71100719
Profile gasket EPDM, 5 pieces
Process gasket universal adapter. Usage: FMB50, FMB70, PMC51, PMP23.
-
Nr 57 Order code 71431380
Profile gasket EPDM/SST, EHEDG, 1 piece
Process gasket universal adapter. Gasket with metal ring. EHEDG approval. Usage: FMB50, FMB70, FMD71/FMD78, PMC51, PMP23.
-
-
-
Order code 71114172
Adapter UNI, DIN11851 DN40, 316L
Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114173
Adapter UNI, DIN11851 DN50, 316L
Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114174
Adapter UNI, DRD DN50, 65mm, 316L
Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114177
Adapter Univ-/Variv N DN40-162 316L
Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114178
Adapter UNI, DIN11851 DN40, 316L, 3.1
Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114205
Adapter UNI, DIN11851 DN50, 316L, 3.1
Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114206
Adapter UNI, DRD DN50, 65mm, 316L, 3.1
Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114208
Adapter Univ-/Variv N DN40 316L 3.1
Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50_110_UNJ/UPJ, PMC51_110_UNJ/UPJ.
-
Order code 52024471
Weld-in dummy, adapter G1-1/2
Material: brass. To avoid any deformation of the adapters 52024469 / 52024470 during welding.
-
Order code 71114176
Adapter UNI, Clamp 2", 316L
Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114178
Adapter UNI, DIN11851 DN40, 316L, 3.1
Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71114207
Adapter UNI, Clamp 2", 316L, 3.1
Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.
-
Order code 71350315
Adapter Uni, Clamp 3", 316L
Process connection. Material: 316L. FDA, 3-A conform. Usage: FMB50, FMB70, FMD71, FMD78, PMC51, PMP23, PMP55.
-
Order code 71114160
Weld-in adapter UNI 6" D85, 316L
Flush mount process connection. Core hole: 85mm. Material: 316L. Seal: silicone profile gasket FDA conform. Usage: FMB50, FMB70.
-
Order code 71114171
Weld-in adapter UNI 6" D85, 316L 3.1
Flush mount process connection. Core hole: 85mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket FDA conform. Usage: FMB50, FMB70.
-
Order code 71304770
Mountingset, housing T14, special
Material: 316L. Usage: mounting kit to attach the own mounting bracket / weather protection cover, FMB70, PMC71, PMP71/PMP75.
-
Order code 71377369
Flushing ring NPS 1" Cl. 150-2500, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377370
Flushing ring NPS 2" Cl. 150-2500, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377371
Flushing ring NPS 3" Cl. 150-2500, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377380
Flushing ring DN50, PN16-400, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377383
Flushing ring DN80, PN16-400, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71102216
Mountingset Cerabar,Deltapilot,Levelflex
Material: 316L. Usage: wall/pipe mounting (2"), FMB50/FMB51/FMB52/FMB53, FMB70, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.
-
Order code XPRFID-
-
-
Predecessor