Hãy thử tìm kiếm theo từ khóa, đơn hàng hoặc mã sản phẩm hoặc số sê-ri, ví dụ: “CM442” hoặc “Thông tin kỹ thuật”
Nhập ít nhất 2 ký tự để bắt đầu tìm kiếm.
  • Lịch sử

Proline Promag P 10
Electromagnetic flowmeter

Picture of electromagnetic flowmeter Proline Promag P 10 for basic process applications ©Endress+Hauser

Proline Promag P 10 for basic process applications

Picture of electromagnetic flowmeter Proline Promag P 10 for basic hazardous process applications ©Endress+Hauser

Proline Promag P 10 for basic process applications also in hazardous areas

Picture of electromagnetic flowmeter Proline Promag P 10 as a remote version ©Endress+Hauser

Proline Promag P 10 with remote transmitter and lap-joint flanges for basic process applications

Proline 10 – uncompromisingly simple

The Electromagnetic Flow Measuring Principle

Flowmeter for basic process applications with easy-to-use operation concept

Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. With its straightforward hard- and software design, Promag P 10 simplifies every step in its life cycle from engineering to servicing at usual Endress+Hauser quality. Heartbeat Technology ensures safe processes.

  • Sản phẩm đơn giản

  • Dễ lựa chọn, cài đặt và vận hành

Công nghệ vượt trội

Đơn giản

  • Sản phẩm tiêu chuẩn

  • Đáng tin cậy, mạnh mẽ và ít bảo trì

Công nghệ vượt trội

Đơn giản

  • Sản phẩm cao cấp

  • Chức năng cao và tiện lợi

Công nghệ vượt trội

Đơn giản

  • Sản phẩm chuyên dụng

  • Dành cho các ứng dụng đòi hỏi cao

Công nghệ vượt trội

Đơn giản

Có thể thay đổi

Lựa chọn FLEX Công nghệ vượt trội Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Fundamental

Đáp ứng nhu cầu đo lường cơ bản

Công nghệ vượt trội
Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Lean

Xử lý dễ dàng các quy trình cốt lõi

Công nghệ vượt trội
Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Extended

Tối ưu hóa quy trình bằng công nghệ tiên tiến

Công nghệ vượt trội
Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Xpert

Làm chủ các ứng dụng khó khăn nhất

Công nghệ vượt trội
Đơn giản

Có thể thay đổi

  • Tổng quan về thông số kỹ thuật

    • Max. measurement error

      Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)

    • Measuring range

      4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)

    • Medium temperature range

      Liner material PFA: –20 to +150 °C (–4 to +302 °F)
      Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

    • Max. process pressure

      PN 40, Class 300, 20K

    • Wetted materials

      Liner: PFA; PTFE
      Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

please wait Loading alternative products

Chọn nhanh

Chọn theo đề xuất của chúng tôi
Giá bán
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

hoặc

Công cụ lựa chọn mã thiết bị

Tiếp tục lựa chọn từ tất cả tùy chọn có thể
  • Lợi ích

    • Diverse applications – wide variety of wetted materials

    • Energy-saving flow measurement – no pressure loss due to cross section constriction

    • Maintenance-free – no moving parts

    • Optimum usability – operation with mobile devices and SmartBlue app or display...

  • Phạm vi ứng dụng

    • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.

    • Dedicated to chemical and process applications with corrosive liquids.

    Device properties

    • Nominal diameter: max. DN 600 (24")

    • All common Ex approvals

    • Liner made of PTFE...

Tín năng và thông số kỹ thuật

Quay lại

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    Flowmeter for basic process applications with easy-to-use operation concept.
    Dedicated to chemical and process applications with corrosive liquids.

  • Sensor features

    Diverse applications – wide variety of wetted materials. Energy-saving flow measurement – no pressure loss due to cross section constriction. Maintenance-free – no moving parts.
    Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.

  • Transmitter features

    Optimum usability – operation with mobile devices and SmartBlue app or display with touch screen. Simple, time-saving commissioning – guided parameterization in advance and in the field. Integrated verification – Heartbeat Technology.
    System integration with HART, Modbus RS485. Flexible operation with app and optional display.

  • Nominal diameter range

    DN 15 to 600 (½ to 24")

  • Wetted materials

    Liner: PFA; PTFE
    Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium

  • Measured variables

    Volume flow, conductivity, mass flow

  • Max. measurement error

    Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)

  • Measuring range

    4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)

  • Max. process pressure

    PN 40, Class 300, 20K

  • Medium temperature range

    Liner material PFA: –20 to +150 °C (–4 to +302 °F)
    Liner material PTFE: –40 to +130 °C (–40 to +266 °F)

  • Ambient temperature range

    Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
    Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)

  • Sensor housing material

    DN 15 to 300 (½ to 12""): AlSi10Mg, coated
    DN 350 to 600 (14 to 24""): Carbon steel with protective varnish

  • Transmitter housing material

    AlSi10Mg, coated

  • Degree of protection

    Standard: IP66/67, Type 4X enclosure

  • Display/Operation

    2.4" LCD display with touch & auto rotate; Configuration and operation via SmartBlue App (Bluetooth) possible

  • Outputs

    4-20 mA HART (active/passive), Pulse/frequency/switch output
    Modbus RS485, 4-20 mA

  • Digital communication

    HART, MODBUS RS485

  • Power supply

    DC 24 V
    AC 100 to 230 V
    AC 100 to 230 V / DC 24 V (non-hazardous area)

  • Hazardous area approvals

    ATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, JPN

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
    Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    Driking water approvals: ACS; NSF61

Tài liệu / Tài liệu hướng dẫn / Phần mềm

Phụ kiện / Phụ tùng thay thế

Nr
Order code
Specification
  • 38
    • Nr 38 Order code 71505739

      Kit S+T-DAT Promag 10, Non-haz/Exd/Z2

      Electronic storage module unprogrammed Usage: Promag 10. Consists of: S+T-DAT.

  • 33
  • 46
  • 33
    • Nr 33 Order code XPD0062-

      ISEM, enhanced, HART, nEx/Z2/Exd

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.

    • Nr 33 Order code XPD0063-

      ISEM, enhanced, Modbus, nEx/Z2/Exd

      Usage: Promag 10. Consists of: ISEM (sensor electronic module) V313-00.

  • 45
  • 44
    • Nr 44 Order code 71323264

      Kit connection board,Promag D/P/W,10/500

      Usage: Promag P 10 Ex, D/W 10 Non-haz, Promag P/W 500 Ex, Sensor connection housing. Consists of: connection board, cover to connection board.

  • 30
    • Nr 30 Order code XPD0080-

      HART, 24VDC, nEx, Alu, 10

      Electronic module E401. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0081-

      HART, 100-230VAC, nEx, Alu, 10

      Electronic module E403. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0082-

      HART, 100-230VAC/24VDC, nEx, Alu, 10

      Electronic module E408. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0083-

      HART, 100-230VAC/24VDC, Exd/Z2, Alu, 10

      Electronic module E404. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

    • Nr 30 Order code XPD0084-

      Mbus,100-230VAC/24VDC, nEx/Exd/Z2,Alu,10

      Electronic module E411. Usage: Promag 10, Promass 10. Consists of: Module cartridge, power supply module, I/O module

  • 50
  • 21
    • Nr 21 Order code 71505748

      Kit cover, blind ,Alu,Non-haz/ Z2/ Div.2

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover blind Alu, O-Ring 110,70x3,53 HNBR.

  • 20
    • Nr 20 Order code 71505749

      Kit cover, glass,Alu,N-haz/Z2/Div.2/Exde

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover sight glass Alu, O-Ring 110,70x3,53 HNBR.

    • Nr 20 Order code 71505750

      Kit cover, sight glass, Alu, 10, Exd

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: cover sight glass Alu, O-Ring 110,70x3,53 HNBR.

  • 70
    • Nr 70 Order code 71505752

      Kit cover gasket, glass/blind, Alu, 10

      Usage: Promag/Promass 10, transmitter housing Alu. Consists of: 10x O-Ring 110,70x3,53 HNBR.

  • 23
    • Nr 23 Order code 71323038

      Kit cover, wall mount, Alu, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu, connection compartment. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.

  • 75
    • Nr 75 Order code 71323042

      Kit cover gasket, wall mount, Ex

      Usage: Promag 10, Promag/Promass/Prosonic Flow 500, wall mount transmitter Alu/cast, connection compartment. Consists of: 10x O-Ring 88,50x3,53 HNBR.

  • 24
    • Nr 24 Order code 71228796

      Kit cover, remote, Alu

      Usage: Promag 10/500, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover Alu, O-Ring 113,90x3,53 HNBR.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

    • Nr 24 Order code 71188176

      Kit cover plastic, remote, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover plastic coated, O-Ring 91,67 x 3,53 FKM.

  • 73
    • Nr 73 Order code 71228798

      Kit housing gaskets, remote, Alu

      Usage: Promag 10/500, Promag 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: O-Ring 113,90x3,53 HNBR for cover, gasket EPDM for housing/sensor L/P/W, O-Ring 29,87x1,78 HNBR for sensor plug.

  • 72
    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

    • Nr 72 Order code 71188179

      Kit cover gasket, plastic, Promag L/P/W

      Usage: Promag 10/400/500/800, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: 10x O-Ring 91,67 x 3,53 FKM.

  • 71
    • Nr 71 Order code 71505753

      Kit interface gaskets, Alu, Promag 10

      Usage: Promag 10, transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x O-Ring 29,87x1,78 HNBR for for sensor plug.

  • 13
    • Nr 13 Order code 71276494

      Kit securing clamp, screw

      Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass, Promag/Promass 500, Promag 10, Promag/Promass/Prosonic Flow/t-mass 500 digital, Promag 400/800(C), (C) = generation index C, sensor connection housing. Consists of: cover clamp, screw M4x16.

  • 87

Tải