Tunable diode laser absorption spectroscopy (TDLAS)
Optimize plant safety and availability. Tunable diode laser absorption spectroscopy (TDLAS) rapidly and reliably measures concentrations in process gas streams in real time.
Bạn đang truy cập trang toàn cầu của Endress+Hauser. Chuyển đến khu vực của bạn để xem nội dung địa phương và mua sắm trực tuyến.
Easy installation, simple operation, and low maintenance equal low cost of ownership
3-pack available for multiple measurements in one unit
SS2100 trace H2O
SS2100 sample conditioning system
SS2100 trace H2O with see-through cover
2-pack with OXY5500 oxygen analyzer
Easy installation, simple operation, and low maintenance equal low cost of ownership
TDLAS
Concentration
Cell Pressure
Cell Temperature
CSA Class I, Division 2
CSA Class I, Zone 2
Using patented tunable diode laser absorption spectroscopy (TDLAS) technology, the SS2100 gas analyzer measures specific gases (H2O, CO2, and H2S) with precision while avoiding interferences that are common with traditional infrared analyzers. The SS2100 analyzer requires little maintenance and does not need recalibration or periodic replacement parts.
Gas analysis: ppb level measurement of H2O, ppm level measurement of H2O, H2S, and CO2, and percent (%) level measurement of H2S and CO2
Natural gas: production, storage, transportation, distribution
Refinery: hydrogen recycle, catalytic reforming, flaring, cracking
Gas processing: fractionation, sour/acid gas removal
LNG: liquefication, custody transfer
Petrochemical: cracking, caustic wash tower
CCUS: measure trace H2S and H2O in 100% CO2
Accurate, real-time measurements
Low cost of ownership, no consumables and virtually maintenance-free and reliable in harsh environments
Available to measure up to 3 analytes in one unit (2-packs or 3-packs)
Provides measurements not hampered by wet-up (absorption) or dry-down (desorption)
Dependable with greater repeatability than surface-based sensors
Analog and serial outputs for remote monitoring
Available for following measurements: H2O, CO2, H2S
Sản phẩm chuyên dụng
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Sản phẩm chuyên dụng
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
| Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
|---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
TDLAS
An advanced gas analyzer for hydrogen sulfide (H2S) measurement. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
1
H2S (Hydrogen Sulfide):
0 to 10 ppmv
0 to 1000 ppmv
0 to 5000 ppmv
0 to 5% volume
Concentration
Cell Pressure
Cell Temperature
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F)
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
316L stainless steel
FKM O-Rings
Glass
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel
CSA Class I, Division 2
CSA Class I, Zone 2
IP66, Type 4X
TDLAS
An advanced gas analyzer for moisture (H2O) measurement. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
1
H2O (Moisture):
0 to 10 ppmv
0 to 100 ppmv
0 to 50 ppmv
0 to 5000 ppmv
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F)
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
316L stainless steel
FKM O-Rings
Glass
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel
CSA Class I, Division 2
CSA Class I, Zone 2
IP66, Type 4X
TDLAS
An advanced gas analyzer for carbon dioxide (CO2) measurement. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
1
CO2 (Carbon Dioxide):
0 to 10 ppmv
0 to 1000 ppmv
0 ppmv to 5000 ppmv
0 to 5% volume
0 to 10% volume
0 to 20% volume
Concentration
Cell Pressure
Cell Temperature
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F)
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
316L stainless steel
FKM O-Rings
Glass
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC
Analog Output: Two 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs: 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs: 2, Flow Alarm, Validation Request
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel
CSA Class I, Division 2
CSA Class I, Zone 2
IP66, Type 4X
TDLAS
Advanced multi-channel gas analyzer for hydrogen sulfide (H2S) and moisture (H2O), also known as a 2-Pack. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
2
H2S (Hydrogen Sulfide):
0 to 10 ppmv (minimum)
0 to 1000 ppmv (maximum)
H2O (Moisture):
0 to 100 ppmv (minimum)
0 to 5000 ppmv (maximum)
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F)
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
316L stainless steel
FKM O-Rings
Glass
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC
Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (H2O): 2, Concentration Alarm, General Fault
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel
CSA Class I, Division 2
CSA Class I, Zone 2
IP66, Type 4X
TDLAS
Advanced multi-channel gas analyzer for hydrogen sulfide (H2S) and carbon dioxide (CO2), also known as a 2-Pack. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
2
H2S (Hydrogen Sulfide):
0 to 10 ppmv (minimum)
0 to 1000 ppmv (maximum)
CO2 (Carbon Dioxide):
0 to 5000 ppmv
0 to 5% volume
0 to 10% volume
0 to 20% volume
Concentration
Cell Pressure
Cell Temperature
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F)
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
316L stainless steel
FKM O-Rings
Glass
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC
Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (CO2)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (CO2): 2, Concentration Alarm, General Fault
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel
CSA Class I, Division 2
CSA Class I, Zone 2
IP66, Type 4X
TDLAS
Advanced multi-channel gas analyzer for hydrogen sulfide (H2S), moisture (H2O), and carbon dioxide (CO2), also known as a 3-Pack. The SS2100 uses tunable diode laser absorption spectroscopy (TDLAS) to determine the concentration of the analyte without coming into physical contact with the stream.
3
H2S (Hydrogen Sulfide):
0 to 10 ppmv (minimum)
0 to 1000 ppmv (maximum)
H2O (Moisture):
0 to 100 ppmv (minimum)
0 to 5000 ppmv (maximum)
CO2 (Carbon Dioxide):
0 to 5000 ppmv
0 to 5% volume
0 to 10% volume
0 to 20% volume
Concentration
Moisture Dew Point
Cell Pressure
Cell Temperature
-20 to 50°C (-4 to 122°F)
Optional: -10 to 60°C (14 to 140°F)
Inlet Pressure: 140 to 350 kPa (20 to 50 psig)
Sample Cell: 800 to 1200 mbara or 950 to 1700 mbara (optional)
316L stainless steel
FKM O-Rings
Glass
120 or 240 VAC ± 10 %, 50 to 60 Hz, 300W
(18 to 24 VDC - optional for electronics only)
3 Amps max at 120 VAC , 1.5 Amps max at 240 VAC
Analog Output: Four 4-20mA Isolated, 1200 ohms at 24 VDC max load
Serial: RS232C and Ethernet (H2S) and RS232C or Ethernet (H2O/CO2)
Protocol: Modbus Gould RTU or Daniel RTU or ASCII
Digital Outputs (H2S): 5, Concentration Alarm, General Fault, Validation Fail, Validation 1 Active, Validation 2 Active
Digital Inputs (H2S): 2, Flow Alarm, Validation Request
Digital Outputs (H2O/CO2): 2, Concentration Alarm, General Fault
Electronics: 304 or 316L stainless steel
Sample System Enclosure: 304 or 316L stainless steel
CSA Class I, Division 2
CSA Class I, Zone 2
IP66, Type 4X
System design and specifications for the SS2100 TDLAS Gas Analyzer
| EN | VI | ||
|
04/03/2025
|
|
|
|
|
19/01/2024
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
04/03/2025 |
|
Cỡ tập tin: |
634.5 KB |
|
Tên tập tin: |
TI01667CEN_0325.pdf |
Commissioning, operation, and maintenance details for the
SS2100-series TDLAS Gas Analyzer Sample Conditioning System
| EN | VI | ||
|
21/02/2024
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
21/02/2024 |
|
Cỡ tập tin: |
1.3 MB |
|
Tên tập tin: |
BA02337CEN_0123.pdf |
Commission, operation, and maintenance details for the
SS2100 TDLAS Gas Analyzer
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
26/06/2023 |
|
Cỡ tập tin: |
10.3 MB |
|
Tên tập tin: |
BA02281CEN_0123.pdf |
Operation and maintenance details for TDLAS gas analyzer
measurement cells
| EN | VI | ||
|
02/08/2024
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
02/08/2024 |
|
Cỡ tập tin: |
1.3 MB |
|
Tên tập tin: |
BA02188CEN_0224.pdf |
Expert-level description and operational information
for device parameters
| EN | VI | ||
|
15/10/2024
|
|
|
|
|
17/09/2021
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
15/10/2024 |
|
Cỡ tập tin: |
2.5 MB |
|
Tên tập tin: |
GP01177CEN_0224.pdf |
Expert-level description and operational information for
device parameters
| EN | VI | ||
|
15/10/2024
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
15/10/2024 |
|
Cỡ tập tin: |
2.6 MB |
|
Tên tập tin: |
GP01180CEN_0224.pdf |
Expert-level description and operational information for
device parameters
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
02/08/2024 |
|
Cỡ tập tin: |
2.1 MB |
|
Tên tập tin: |
GP01181CEN_0224.pdf |
Instructions for cleaning the 0.1 m, 0.8 m, 8 m/28 m
measurement cell mirror for multiple TDLAS gas analyzers
| EN | VI | ||
|
29/07/2024
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
29/07/2024 |
|
Cỡ tập tin: |
382 KB |
|
Tên tập tin: |
EA01381CEN_0224.pdf |
Safety Instructions for the SS2100 2-Pack, 3-Pack TDLAS Gas Analyzer
| EN | VI | ||
|
02/02/2026
|
|
|
|
|
01/10/2025
|
|
|
|
|
08/10/2021
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
02/02/2026 |
|
Cỡ tập tin: |
2.4 MB |
|
Tên tập tin: |
XA02751CEN_0326.pdf |
Safety Instructions for the SS2100 TDLAS Gas Analyzer
| EN | VI | ||
|
22/10/2024
|
|
|
|
Ngôn ngữ: |
Tiếng Anh |
|
Phiên bản: |
22/10/2024 |
|
Cỡ tập tin: |
1.4 MB |
|
Tên tập tin: |
XA02750CEN_0324.pdf |
Phụ kiện
Chúng tôi sử dụng cookie để nâng cao trải nghiệm duyệt web của bạn, thu thập số liệu thống kê để tối ưu hóa chức năng của trang web và cung cấp nội dung hoặc quảng cáo phù hợp.
Bằng cách chọn "Chấp nhận tất cả", bạn đồng ý với việc sử dụng cookie của chúng tôi.
Để biết thêm chi tiết, vui lòng xem lại Chính sách cookie của chúng tôi.