Hydrostatic
Level measurement
Deltapilot FMB70

Deltapilot FMB70 hygienic housing ©Endress+Hauser
Deltapilot FMB70 aluminum housing ©Endress+Hauser
Deltapilot FMB70 separate housing ©Endress+Hauser
Deltapilot FMB70 separate housing hygienic ©Endress+Hauser

Pressure measuring principle

Deltapilot FMB70 ©Endress+Hauser

Highest performance pressure sensor with the Contite cell for hydrostatic level measurement

The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.

Lựa chọn nhanh

Chọn trong số các tùy chọn do chúng tôi đề xuất
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

hoặc

Cấu hình riêng

Tiếp tục lựa chọn từ tất cả các tùy chọn có thể
  • Lợi ích

    • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation

    • Best batch-to-batch repeatability and long-term stability

    • ...

  • Phạm vi ứng dụng

    For level and/or pressure measurement.

    • Process connections: Threads, flanges and hygienic connections

    • Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

    • Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)

    • Accuracy: ±0.075%

    • International...

Tín năng và thông số kỹ thuật

Quay lại

Details

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Specialities

    Diagnostic functions

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC (Non Ex)

  • Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Process pressure absolute / max. overpressure limit

    40 bar (600 psi)

  • Pressure measuring range

    100mbar...10bar
    (1.5psi...150psi)

  • Main wetted parts

    Alloy C
    316L

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Max. measurement distance

    100m (328ft) H2O

  • Communication

    4...20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175, MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approval

    GL/ DNV

  • Drinking water approvals

    NSF

  • Options

    HistoROM/M-Dat
    4-line digital display
    SS- or Aluminiumhousing

    Separate housing

  • Application limits

    Measuring cell: Contite,
    condensate-proof, watertight,
    metal welded

    If pressurized, possibly use
    differential pressure measurement
    with two pressure
    transmitters. Observe ratio
    head pressure : hydrostatic
    pressure

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version
    Modular Deviceplatform

  • Supply voltage

    4...20 mA HART

    10,5...45 VDC (Non Ex):

    Ex ia: 10,5...30 VDC

    PROFIBUS PA:

    9...32 VDC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 VDC (Non Ex)

  • Reference Accuracy

    Standard 0,1%
    Optional 0,075%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Smallest calibratable span

    25 mbar (3.63 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. overpressure limit

    40 bar (600 psi)

  • Process connection

    Thread:

    G1 1/2, MNPT1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Material process membrane

    316L, AlloyC,

    Gold-Rhodium

  • Material gasket

    None, measuring cell welded

  • Fill fluid

    Inert oil,

    Synthetic oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4 ... 20 mA HART
    PROFIBUS PA
    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175
    MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approvals

    GL, DNV

  • Drinking water approvals

    NSF

  • Specialities

    Gold-rhodium coated membrane

Tài liệu / Tài liệu hướng dẫn / Phần mềm

Phụ kiện / Phụ tùng thay thế

Nr
Order code
Specification
  • 12
    • Nr 12 Order code 52020440

      Mounting set housing T14/T15 / sensor

      Consists of: 2x O-ring 45.69x2.62 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 12 Order code 71020596

      Mounting set housing T17 / sensor

      Consists of: 2x O-ring 45.62x69x2.62 EPDM. 1x profile gasket 51.4x57.2x1.6 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 13
    • Nr 13 Order code 52022418

      Push button housing, PA/FF

      Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 13 Order code 52024110

      Push button housing, HART, version 2

      Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.

  • 15
    • Nr 15 Order code 52020760

      Cable gland M20, gasket

      Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020761

      Cable entry G1/2, gasket, adapter

      Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 52020763

      Plug 3-pole, M12, gasket

      Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Order code 52006263

      Socket for plug 4p-125V, 4A-M12

      M12 socket for plug. Self confectionery connection. Usage: plug M12.

    • Order code 71043576

      Housing filter plastic T15, 3 pieces

      Consists of: filter plug, Gore-Tex filter. Usage: housing T15, FMB70.

    • Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 20 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 25
    • Nr 25 Order code 71002774

      Cover T17 316L, gasket

      Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 20
    • Nr 20 Order code 71002810

      Cover T17 316L, sight glass, gasket

      Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.

    • Nr 20 Order code 71002811

      Cover T17 316L, sight glass PC, gasket

      Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.

    • Nr 20 Order code 71245247

      Cover T14/T15 Alu, sight glass, gasket

      Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 21
    • Nr 21 Order code 52020429

      Sealing EPDM, F30/31/34, T14/15, 5 pcs.

      Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.

  • 25
    • Nr 25 Order code 52020432

      Cover T14/T15 Alu, gasket

      Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 30
    • Nr 30 Order code 71026358

      Electronics HART Ex, v2.10

      4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71026359

      Electronics HART Ex, ext. p. b., v2.10

      4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071824

      Electronics PA, HW02.00, SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071825

      Electronics PA, ext. p.b., HW02.00,SW4.0

      PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071826

      Electronics FF, HW2.00, SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71071827

      Electronics FF, ext. p.b., HW2.00,SW3.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 30 Order code 71196092

      Electronic HART Ex, v2.11

      4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71196093

      Electronics HART Ex, ext. p. b., v2.11

      4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71214890

      Electronics FF, ext. p.b.,HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71214892

      Electronics FF, HW2.00, SW4.00

      FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.

    • Nr 30 Order code 71263933

      Electronics HART Ex, v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71263934

      Electronics HART Ex, ext. p. b., v2.20

      4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71386147

      Elektronics HART Ex, v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

    • Nr 30 Order code 71386153

      Electronics HART Ex, ext. p. b., v2.30

      4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).

  • 31
    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 31 Order code 52027785

      HistoROM / M-DAT, 16K

      Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 35
    • Nr 35 Order code 52020434

      Terminal 3-pole, RFI, HART, TIIS

      RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75, TIIS Ex ia.

    • Nr 35 Order code 52026605

      Terminal 2-pole, RFI, PA, TIIS

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.

    • Nr 35 Order code 52027691

      Terminal 2-pole, RFI, FF, Ex

      RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028473

      Terminal 3p., RFI, HART, OVP, TIIS

      Overvoltage protection, RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028475

      Terminal 2-pole, RFI, PA, OVP, Ex

      Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71028476

      Terminal 2-pole, RFI, FF, OVP, Ex

      Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71121574

      Terminal 2-pole, RFI, PA, Ex

      RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.

    • Nr 35 Order code 71191892

      Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd

      RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

    • Nr 35 Order code 71191894

      Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd

      Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.

  • 40
    • Nr 40 Order code 71002865

      Display module VU340, Cbar/Dbar/Dpilot S

      Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.

    • Order code 71043886

      Cable PE, L=2m/80inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043888

      Cable PE, L=5m/200inch, separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71043889

      Cable PE, L=10m/400inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 71070738

      Cable FEP, L=5m/200inch,separate housing

      Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Order code 214880-0002

      Weld-in adapter UNI D65, 316L

      Flush mount process connection. Core hole: 65mm. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52002041

      Weld-in adapter DRD DN50, 316L

      Front-flush mounting of devices with DRD flange. Material: 316L. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52006262

      Weld-in adapter UNI D85, 316L

      Flush mount process connection. Core hole: 85mm. Material: 316L. Seal: silicone profile gasket. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52 PMC51, PMP23, PMP55, PMP75.

    • Order code 52010173

      Weld-in adapter UNI D85, 316L, 3.1

      Flush mount process connection. Core hole: 85mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52010174

      Weld-in adapter UNI D65, 316L, 3.1

      Flush mount process connection. Core hole: 65mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A compliant. Usage: FMB50, FMB70, FMD71/FMD78, FMI51/FMI52, FMP52, FTI51/FTI52, PMC51, PMP23, PMP55, PMP75.

    • Order code 52011899

      Weld-in adapter DRD DN50, 316L, 3.1

      Flush mount process connection of devices with DRD flange. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: PTFE flat. FDA compliant. Usage: FMB50, FMB70, FMD78, FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMC71, PMP51/PMP55, PMP75.

    • Order code 52024469

      Weld-in adapter G1-1/2, 316L

      Mounting process connection G1-1/2. Material: 316L. Correct installation only with dummy. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Order code 52024470

      Weld-in adapter G1-1/2, 316L, 3.1

      Mounting process connection G1-1/2. Material: 316L. Inspection cert. EN10204-3.1 material. Usage: FMB50/FMB51/FMB52, FMB70, PMC51, PMC71, PMP51/PMP52, PMP71/PMP75.

    • Order code 916743-0000

      Weld-in adapter DRD DN50, 304

      Flush mount process connection. Material: 304. Seal: PTFE flat. FDA compliant. Usage: Flush mount FTL50/FTL50H/FTL51/FTL51C/FTL51H, PMC51, PMP51, PMP55, PMC71, PMP75, FMB50, FMB70, FMD78.

  • 50
    • Order code 52024228

      Flat seal 50x65x1 PTFE, FDA, 5 pieces

      Fit to weld-in adapter DRD-DN50. Flush mount FTL50H/FTL51H, PMC51, pressure device.

  • 57
    • Nr 57 Order code 52023572

      Profile gasket silicone, 5 pieces

      Process gasket universal process adapt. FDA listed. Usage: FMB50, FMB70, FMI51/FMI52, FTI51/FTI52/FTI55, PMC51.

    • Nr 57 Order code 71100719

      Profile gasket EPDM, 5 pieces

      Process gasket universal adapter. Usage: FMB50, FMB70, PMC51, PMP23.

    • Order code 71114172

      Adapter UNI, DIN11851 DN40, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114173

      Adapter UNI, DIN11851 DN50, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114174

      Adapter UNI, DRD DN50, 65mm, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114177

      Adapter UNI, Varivent N, 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114205

      Adapter UNI, DIN11851 DN50, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114206

      Adapter UNI, DRD DN50, 65mm, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114208

      Adapter UNI, Varivent N, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50_110_UNJ/UPJ, PMC51_110_UNJ/UPJ.

    • Order code 52024471

      Weld-in dummy, adapter G1-1/2

      Material: brass. To avoid any deformation of the adapters 52024469 / 52024470 during welding.

    • Order code 71114176

      Adapter UNI, Clamp 2", 316L

      Slotted-nut, process connection. Material: 316L. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114178

      Adapter UNI, DIN11851 DN40, 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114207

      Adapter UNI, Clamp 2", 316L, 3.1

      Slotted-nut, process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket. FDA, EHEDG, 3-A conform. Usage: FMB50, PMC51.

    • Order code 71114160

      Weld-in adapter UNI 6" D85, 316L

      Flush mount process connection. Core hole: 85mm. Material: 316L. Seal: silicone profile gasket FDA conform. Usage: FMB50, FMB70.

    • Order code 71114171

      Weld-in adapter UNI 6" D85, 316L 3.1

      Flush mount process connection. Core hole: 85mm. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone profile gasket FDA conform. Usage: FMB50, FMB70.

    • Order code 71304770

      Mountingset, housing T14, special

      Material: 316L. Usage: mounting kit to attach the own mounting bracket / weather protection cover, FMB70, PMC71, PMP71/PMP75.

    • Order code 71102216

      Mountingset Cerabar,Deltapilot,Levelflex

      Material: 316L. Usage: wall/pipe mounting (2"), FMB50/FMB51/FMB52/FMB53, FMB70, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

  • Sản phẩm cũ

Vui lòng chọn thị trường / khu vực của bạn