Proline Promass E 200 Cost-effective – multi-purpose device
Tổng quan về thông số kỹ thuật
-
Max. measurement error
Mass flow (liquid): ±0.25 % (standard)
Volume flow (liquid): ±0.25 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Medium temperature range
–40 to +150 °C (–40 to +302 °F)
-
Max. process pressure
PN 100, Class 600, 63K
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)
Phạm vi ứng dụng
The robust Promass E has a long-standing reputation as a reliable solution accurately measuring liquids and gases in a wide range of standard applications in the chemical industry. With genuine loop-powered technology, Proline E 200 enables cost-effective and seamless integration into existing infrastructures. The flowmeter offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Accurate measurement of liquids and gases for a wide range of standard applications.
Device properties
Compact dual-tube sensor
Medium temperature up to +150 °C (+302 °F)
Process pressure: up to 100 bar (1450 psi)
Loop-powered technology
Robust dual-compartment housing
Plant safety: worldwide approvals (SIL, Haz. area)
Lợi ích
Cost-effective – multipurpose device; an alternative to conventional volumetric flowmeters
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in-/outlet run needs
Convenient device wiring – separate connection compartment
Safe operation – no need to open the device due to display with touch control, background lighting
Integrated verification – Heartbeat Technology
Video
-
The Coriolis Flow Measuring Principle
Lựa chọn Extended
-
Sản phẩm cao cấp
- Chức năng cao và tiện lợi
Công nghệ vượt trội
Đơn giản

-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
Sản phẩm cũ
Câu chuyện thành công
-
Measuring principle
Coriolis
-
Product headline
Genuine loop-powered flowmeter for minimized cost of ownership.
Accurate measurement of liquids and gases for a wide range of standard applications. -
Sensor features
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.25 % (standard)
Volume flow (liquid): ±0.25 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–40 to +150 °C (–40 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA) -
Hazardous area approvals
ATEX, IECEx, cCSAus, JPN, UK Ex
-
Product safety
CE, C-Tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Measuring principle
Coriolis
-
Product headline
Genuine loop-powered flowmeter for minimized cost of ownership.
Accurate measurement of liquids and gases for a wide range of standard applications. -
Sensor features
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.25 % (standard)
Volume flow (liquid): ±0.25 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–40 to +150 °C (–40 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA) -
Hazardous area approvals
ATEX, IECEx, cCSAus, JPN, UK Ex
-
Product safety
CE, C-Tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
Measuring principle
Coriolis
-
Product headline
Genuine loop-powered flowmeter for minimized cost of ownership.
Accurate measurement of liquids and gases for a wide range of standard applications. -
Sensor features
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi). -
Transmitter features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). -
Nominal diameter range
DN 8 to 50 (⅜ to 2")
-
Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.25 % (standard)
Volume flow (liquid): ±0.25 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
–40 to +150 °C (–40 to +302 °F)
-
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
-
Sensor housing material
1.4301 (304), corrosion resistant
-
Transmitter housing material
AlSi10Mg, coated
-
Degree of protection
IP66/67, type 4X enclosure
-
Display/Operation
4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive) -
Inputs
None
-
Digital communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
-
Power supply
DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA) -
Hazardous area approvals
ATEX, IECEx, cCSAus, JPN, UK Ex
-
Product safety
CE, C-Tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
-
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
-
Hygienic approvals and certificates
3-A, EHEDG, cGMP
-
-
Thông tin kĩ thuật (TI)
TI Proline Promass E 200
-
Thông tin kĩ thuật (TI)
bản tiếng Anh - 11/2024Coriolis flowmeter
EN VI Chọn ngôn ngữ khác 01/11/202401/01/202101/12/2016Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/11/2024
Cỡ tập tin:
4.2 MB
Tên tập tin:
TI01300DEN_0324-00.pdf
-
-
-
Hướng dẫn vận hành (BA)
BA Proline Promass E 200
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 11/2024Coriolis flowmeter
PROFIBUS PAEN VI Chọn ngôn ngữ khác 01/11/202401/01/202101/12/2016Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/11/2024
Cỡ tập tin:
4.4 MB
Tên tập tin:
BA01639DEN_0324-00.pdf
-
-
-
Hướng dẫn vận hành (BA)
BA Proline Promass E 200
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 11/2024Coriolis flowmeter
FOUNDATION fieldbusEN VI Chọn ngôn ngữ khác 01/11/202401/01/202101/12/2016Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/11/2024
Cỡ tập tin:
4.8 MB
Tên tập tin:
BA01637DEN_0324-00.pdf
-
-
-
Hướng dẫn vận hành (BA)
BA Proline Promass E 200
-
Hướng dẫn vận hành (BA)
bản tiếng Anh - 11/2024Coriolis flowmeter
HARTEN VI Chọn ngôn ngữ khác 01/11/202401/01/202101/12/2016Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/11/2024
Cỡ tập tin:
4.8 MB
Tên tập tin:
BA01638DEN_0324-00.pdf
-
-
-
Tham số thiết bị (GP)
Proline Promass 200 FOUNDATION Fieldbus Description of Device Parameters
-
Tham số thiết bị (GP)
bản tiếng Anh - 08/2018Coriolis flowmeter
EN VI Chọn ngôn ngữ khác 01/08/201801/12/201624/11/2015Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/08/2018
Cỡ tập tin:
1.9 MB
Tên tập tin:
GP01030DEN_0318.pdf
-
-
-
Tham số thiết bị (GP)
Proline Promass 200 HART Description of Device Parameters
-
Tham số thiết bị (GP)
bản tiếng Anh - 08/2018Coriolis flowmeter
EN VI Chọn ngôn ngữ khác 01/08/201801/12/201622/06/201501/07/2011Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/08/2018
Cỡ tập tin:
1.6 MB
Tên tập tin:
GP01010DEN_0418.pdf
-
-
-
Tham số thiết bị (GP)
Proline Promass 200 PROFIBUS PA Description of Device Parameters
-
Tham số thiết bị (GP)
bản tiếng Anh - 08/2018Coriolis flowmeter
EN VI Chọn ngôn ngữ khác 01/08/201801/12/201603/08/2015Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/08/2018
Cỡ tập tin:
1.6 MB
Tên tập tin:
GP01029DEN_0318.pdf
-
-
-
Hướng dẫn ngắn gọn (KA)
Proline 200 FOUNDATION Fieldbus Brief Operating Instructions
-
Hướng dẫn ngắn gọn (KA)
bản tiếng Anh - 08/2018Transmitter with Coriolis sensor
EN VI Chọn ngôn ngữ khác 01/08/201801/12/2016Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/08/2018
Cỡ tập tin:
1.3 MB
Tên tập tin:
KA01267DEN_0218.pdf
-
-
-
Hướng dẫn ngắn gọn (KA)
Flowmeter Proline Promass E
-
Hướng dẫn ngắn gọn (KA)
bản tiếng Anh - 08/2022Coriolis sensor
EN VI Chọn ngôn ngữ khác 01/08/202201/10/201701/02/201701/12/2016Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/08/2022
Cỡ tập tin:
780.2 KB
Tên tập tin:
KA01260DEN_0422-00.pdf
-
-
-
Hướng dẫn ngắn gọn (KA)
Proline 200 HART Brief Operating Instructions
-
Hướng dẫn ngắn gọn (KA)
bản tiếng Anh - 08/2018Transmitter with Coriolis sensor
EN VI Chọn ngôn ngữ khác 01/08/201801/12/2016Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/08/2018
Cỡ tập tin:
986 KB
Tên tập tin:
KA01268DEN_0218.pdf
-
Chọn theo đề xuất của chúng tôi
-
-- selected coding-- selected label99.999,00Chọn sẵn
-
Promass E 200, 8E2C08, DN08 3/8"99.999,00
-
Promass E 200, 8E2C15, DN15 1/2"99.999,00
-
Promass E 200, 8E2C25, DN25 1"99.999,00
-
Promass E 200, 8E2C40, DN40 1 1/2"99.999,00
-
Promass E 200, 8E2C50, DN50 2"99.999,00
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
- Bản vẽ CAD Bản vẽ CAD
- Bản vẽ CAD
-
Giá cho mỗi chi tiết
- Các add-on tùy chọn
Công cụ lựa chọn mã thiết bị
Thường mua kèm theo
Phụ kiện