Nhập ít nhất 2 ký tự để bắt đầu tìm kiếm.
  • Lịch sử

Manual or automatic retractable assembly Cleanfit CPA472D

Cleanfit CPA472D - Retractable assembly for harsh process conditions ©Endress+Hauser
Cleanfit CPA472D - Detail sensor holder ©Endress+Hauser
Cleanfit CPA472D assembly for harsh process conditions ©Endress+Hauser

Heavy-duty assembly for chemical and power industries

The Cleanfit CPA472D assembly is designed for harsh process conditions. It offers a great variety of rugged materials to operate your sensors safely even under high pressure, high temperature or in aggressive media. The assembly allows you to replace sensors without interrupting the process or to clean and calibrate them automatically via the optional control system. Benefit from easy, time-saving sensor handling and an extended operating life of the sensors.

  • Sản phẩm đơn giản

  • Dễ lựa chọn, cài đặt và vận hành

Công nghệ vượt trội

Đơn giản

  • Sản phẩm tiêu chuẩn

  • Đáng tin cậy, mạnh mẽ và ít bảo trì

Công nghệ vượt trội

Đơn giản

  • Sản phẩm cao cấp

  • Chức năng cao và tiện lợi

Công nghệ vượt trội

Đơn giản

  • Sản phẩm chuyên dụng

  • Dành cho các ứng dụng đòi hỏi cao

Công nghệ vượt trội

Đơn giản

Có thể thay đổi

Lựa chọn FLEX Công nghệ vượt trội Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Fundamental

Đáp ứng nhu cầu đo lường cơ bản

Công nghệ vượt trội
Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Lean

Xử lý dễ dàng các quy trình cốt lõi

Công nghệ vượt trội
Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Extended

Tối ưu hóa quy trình bằng công nghệ tiên tiến

Công nghệ vượt trội
Đơn giản
  • F
  • L
  • E
  • X

Lựa chọn Xpert

Làm chủ các ứng dụng khó khăn nhất

Công nghệ vượt trội
Đơn giản

Có thể thay đổi

  • Tổng quan về thông số kỹ thuật

    • Process temperature

      0 to 140 °C (32 to 284 °F)

    • Process pressure

      0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
      0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

Chọn nhanh

Chọn theo đề xuất của chúng tôi
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

hoặc

Công cụ lựa chọn mã thiết bị

Tiếp tục lựa chọn từ tất cả tùy chọn có thể
  • Lợi ích

    • Extremely robust: Suitable for use with pressures of up to 10 bar and temperatures of up to 140° C even as PEEK, PVDF, conductive PVDF versions

    • Maximum chemical resistance ensures long operating times

    • No process interruption for electrode cleaning and...

  • Phạm vi ứng dụng

    The Cleanfit CPA472D is intended for installation in tanks or pipes in:

    • Chemical industry

    • Power plants

    • Biodiesel plants

    It is suitable for use with pressures of up to 10 bar.

Tín năng và thông số kỹ thuật

Quay lại

Details

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes

  • Installation

    Retractable holder

  • Characteristic

    For tanks and process vats and pipelines or pipes (min. DN80)
    The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar

  • Design

    Manual or pneumatical

  • Material

    Electrode holder, rinse chamber and raised face:
    PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
    Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)

  • Dimension

    Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)

  • Process temperature

    0 to 140 °C (32 to 284 °F)

  • Process pressure

    0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
    0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

  • Connection

    Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼

  • Measuring principle

    Potentiometric

  • Application

    Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes

  • Installation

    Retractable holder

  • Characteristic

    For tanks and process vats and pipelines or pipes (min. DN80)
    The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar

  • Design

    Manual or pneumatical

  • Material

    Electrode holder, rinse chamber and raised face:
    PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
    Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)

  • Dimension

    Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)

  • Process temperature

    0 to 140 °C (32 to 284 °F)

  • Process pressure

    0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
    0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

  • Connection

    Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼

Tài liệu / Tài liệu hướng dẫn / Phần mềm

Phụ kiện / Phụ tùng thay thế

Nr
Order code
Specification

Vui lòng chọn thị trường / khu vực của bạn