Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Bio sleeve:
Body: 316L stainless steel
Window: Proprietary material, optimized for bioprocesses
Surface finish: Ra 15 with Electropolish to ASME BPE SF4 finish
Adhesive: USP Class VI and ISO 10993 compatible
Bio sleeve:
Autoclave, gamma irradiation
The bio multi optic and bio sleeve duo delivers reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectra quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactor setups.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Patented self-focusing lens with automatic alignment for optimal spectral quality and reproducibility
Improved ease of use with less probe service and maintenance
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Autoclavable, gamma sterilizable, and compatible with standard cleaning protocols (bio sleeve), with reduced risk of cross-contamination (via non-contact multi optic)
120 mm version is compatible with Endress+Hauser flow assembly CYA680
Sản phẩm cao cấp
Công nghệ vượt trội
Đơn giản
Sản phẩm chuyên dụng
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | VI | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
467.9 KB |
Tên tập tin: |
TI01635CEN_0322.pdf |
System design and specifications for the multi optic calibration
and verification kit
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
26/06/2023 |
Cỡ tập tin: |
478.7 KB |
Tên tập tin: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications
for the Raman Rxn-10 probe
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
423 KB |
Tên tập tin: |
TI01629CEN_0322.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | VI | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
1.8 MB |
Tên tập tin: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
26/06/2023 |
Cỡ tập tin: |
996.4 KB |
Tên tập tin: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
1.2 MB |
Tên tập tin: |
BA02160CEN_0322.pdf |
Quick start guide for the Raman Rxn-10 probe
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
895.3 KB |
Tên tập tin: |
KA01546CEN_0322.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | VI | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
31/05/2023 |
Cỡ tập tin: |
1 MB |
Tên tập tin: |
KA01551CEN_0322.pdf |
An overview brochure about our Raman spectroscopy analyzer
and probe portfolio, powered by Kaiser Raman technology, for
the bioprocessing / biopharmaceutical industry (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic,
Raman single use optic system, bio multi optic with bio sleeve, and
Raman flow assembly), powered by Kaiser Raman technology.
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
19/06/2023 |
Cỡ tập tin: |
6.8 MB |
Tên tập tin: |
IN01228CEN_0223.pdf |
An overview brochure about our Raman spectroscopy multi use and
single use bioprocessing portfolio (including the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-46 probe, Raman single use
optic system, bio multi optic, and bio sleeve), powered by Kaiser Raman
technology.
Ngôn ngữ: |
Tiếng Anh |
Phiên bản: |
13/12/2023 |
Cỡ tập tin: |
4 MB |
Tên tập tin: |
IN01267CEN_0223.pdf |