Hydrostatic
Level measurement
Deltapilot FMB53

Deltapilot FMB53 ©Endress+Hauser

Pressure measuring principle

Deltapilot FMB53 ©Endress+Hauser

Pressure sensor with Contite measuring cell for hydrostatic level measurement

The Deltapilot FMB53 is a cable version with mounting clamp. This device with the Contite measuring cell is typically used in the environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.

Lựa chọn nhanh

Chọn trong số các tùy chọn do chúng tôi đề xuất
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

hoặc

Cấu hình riêng

Tiếp tục lựa chọn từ tất cả các tùy chọn có thể
  • Lợi ích

    • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

    • Modular concept for easy replacement of display or electronics

    • Seamless and independent system...

  • Phạm vi ứng dụng

    For level measurement.

    • Process connection: Suspension clamp

    • Temperature: With PE cable: -10 to +70°C (+14 to +158°F),

      with FEP cable: -10 to +80°C (+14 to +176°F)

    • Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)

    • Accuracy: ±0.2...

Tín năng và thông số kỹ thuật

Quay lại

Details

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Cable version with suspension clamp

  • Specialities

    Modularity to differential pressure and process pressure devices (replacable display, universal electronics)

    diagnostic functions

    Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)

  • Supply / Communication

    4...20mA HART:
    10,5...45V DC
    Ex ia: 10,5...30V DC
    PROFIBUS PA /
    FOUNDATION Fieldbus:
    9...32V DC (Non Ex)

  • Accuracy

    Standard 0,2%
    Optional 0,1%

  • Long term stability

    0,05% of URL/year

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Process temperature

    PE cable: -10°C…70°C / 14°F…158°F
    FEP cable: -10°C…80°C / 14°F…176°F

  • Process pressure absolute / max. overpressure limit

    40 bar (600 psi)

  • Pressure measuring range

    100mbar...10bar
    (1.5psi...150psi)

  • Main wetted parts

    Alloy C
    316L
    Cable (PE/FEP)
    optional coating AuPt
    optional coating AuRh

  • Process connection

    Mounting clamp

  • Max. measurement distance

    100m (328ft) H2O

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1

    NACE MRO175

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Drinking water approvals

    KTW/ NSF/ ACS

  • Options

    Initial device settings
    Overvoltage protection

  • Application limits

    If pressurized, usage of two pressure transmitters to measure the differential pressure (electronic dP)
    Observe ratio head pressure : hydrostatic pressure

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Pressure transmitter for pressure or hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Cable version with suspension clamp

  • Supply voltage

    4...20 mA HART

    10,5...45 VDC (Non Ex):

    Ex ia: 10,5...30 VDC

    PROFIBUS PA:

    9...32 VDC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 VDC (Non Ex)

  • Reference Accuracy

    Standard 0,2%
    Optional 0,1%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    PE cable: -10°C…70°C / 14°F…158°F
    FEP cable: -10°C…80°C / 14°F…176°F

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Smallest calibratable span

    10 mbar (1.45 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. Turn down

    100:1

  • Max. overpressure limit

    40 bar (600 psi)

  • Process connection

    Mounting clamp

  • Material process membrane

    316L, AlloyC,

    Gold-Rhodium

    PE, FEP

  • Material gasket

    Viton, EPDM, Kalrez, none

  • Fill fluid

    Inert oil,

    Synthetic oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

  • Safety approvals

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0175

  • Marine approvals

    GL/ ABS/ LR/ BV/ DNV

  • Drinking water approvals

    KTW/ NSF/ ACS

  • Specialities

    Modularity to differential pressure and process pressure devices (replacable display, universal electronics)

    Diagnostic functions

    Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)

Tài liệu / Tài liệu hướng dẫn / Phần mềm

Phụ kiện / Phụ tùng thay thế

Nr
Order code
Specification
  • 19
    • Nr 19 Order code 71111056

      Housing filter VA,EPDM,F15/31/T14/17,1pc

      Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Nr 19 Order code 71219639

      Housing filter VA, VMQ, F15, T17, 1 pc.

      Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

  • 20
    • Nr 20 Order code 52027000

      Cover F15 316L, gasket

      Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15, stainless steel.

    • Nr 20 Order code 52027002

      Cover F15 316L, sight glass, gasket

      Sight glass: glass. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15, stainless steel.

    • Nr 20 Order code 52028207

      Cover F15, sight glass PC, 316L, gasket

      Sight glass: Polycarbonate PC. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15 stainless steel, FMB50/FMB51/FMB52/FMB53,PMC51, PMP51/PMP55, not for EEx ia (intrinsically safe).

    • Nr 20 Order code 52028267

      Cover F15 316L,claw,sight glass,gasket

      Sight glass glass. Cover claw. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: dust Ex version, housing F15 stainless steel, FMB50/FMB51/FMB52/FMB53. PMC51, PMP51/PMP55.

    • Nr 20 Order code 52028268

      Cover F15 316L, claw, gasket

      Cover claw. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15 stainless steel, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Nr 20 Order code 71092705

      Cover F30/31/34 Alu, gasket

      Material: aluminium. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.

    • Nr 20 Order code 71092707

      Cover F30/31/34 Alu, sight glass, gasket

      Material: aluminium. Sight glass: mineral glass. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.

  • 21
    • Nr 21 Order code 52020429

      Sealing EPDM, F30/31/34, T14/15, 5 pcs.

      Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.

    • Nr 21 Order code 52028179

      Gasket 67.5x2.9x1.5 VMQ/PTFE, 5 pieces

      Profile gasket cover. Usage: housing F15 stainless steel.

  • 15
    • Nr 15 Order code 52002449

      Cable gland M20 PA, o-ring VMQ

      Consists of: cable gland M20, plastic. O-ring 18.72 x 2.62 VMQ. Usage: Housing F15, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.

    • Nr 15 Order code 52005984

      Plug 3p M12/M20, gasket

      Consists of: terminal block, gasket. Usage: FMB50/51/52/53, PMC51, PMD55, PMP51/55.

    • Nr 15 Order code 52020762

      Plug 2/7-pole, HAN7D, gasket

      Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.

    • Nr 15 Order code 71092709

      Cable gland M20 PA, O-ring EPDM/PTFE

      Consists of: cable gland M20, synthetic. O-ring 17.0x2.0 EPDM + PTFE/FDA. Usage: housing F30/31, FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.

    • Nr 15 Order code 71092711

      Cable gland M20 Metal, gasket

      Consists of: cable gland M20, metal. O-ring 17.0x2.0 EPDM + PTFE/FDA. Usage: housing F15/F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55, housing F30 PMD55.

    • Nr 15 Order code 71092712

      Cable entry G1/2, gasket, adapter

      Consists of: gasket 18.72x2.51 NBR 70. Adapter M20 > G1/2. Not for Ex d. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.

    • Nr 15 Order code 71120017

      Plug valve, F30/F31, seal NBR

      Consists of: plug, seal, screw. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.

    • Order code 71290825

      Ground terminal T14/T15/T17, F30/F31

      Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.

  • 40
    • Nr 40 Order code 71091670

      Display module VU340, Cbar/Dbar/Dpilot M

      Digital display, 3 push buttons, snapped bracket. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.

  • 30
  • 41
    • Nr 41 Order code 71094113

      Holder Display Dbar/Cbar/Dpilot M

      Usage: display module VU340, FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.

    • Order code 71220481

      Membran protection FMB51/52/53, 5 pieces

      Usage: FMB51/FMB52/FMB53.

    • Order code 71067434

      Modification name plate, non Ex

      Blank. To fill in the new order code when a non Ex instrument has been modified. Usage: FMB50/FMB51/FMB52, FMR230/FMR231, FMR240/FMR244/FMR245, FMR250,FMR530/FMR532,FTL50/FTL50H/FTL51/ FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/ FTL85, NMR81, PMC51, PMC71, PMP51/PMP55.

    • Order code 52006263

      Socket for plug 4p-125V, 4A-M12

      M12 socket for plug. Self confectionery connection. Usage: plug M12.

    • Order code 52010285

      Cable 4x0.34, box M12,Cu Sn/Ni,90o,L=5m

      M12 plug connector. 5m cable PVC, Cu Sn/Ni lock. Usage: FMB50/FMB51/FMB52/FMB53, FTL31/FTL33, FTW23, FTW33, PMC11, PMC21, PMC51, PMP11, PMP21/PMP23, PMP51/PMP55, PTC31B, PTP31B/PTP33B.

    • Order code 71114212

      Plug connector M12 90deg

      Self confectionery connection. Usage: plug M12.

    • Order code 71125862

      Extension cable shortening kit FMB53

      Shortening kit for cable Usage: FMB53.

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.

  • Sản phẩm cũ

Vui lòng chọn thị trường / khu vực của bạn