The Endress+Hauser Group

Trung tâm truyền thông

Sự kiện

Xây dựng sự nghiệp cùng Endress+Hauser

Tra cứu sản phẩm

Thông tin liên hệ

Radar measurement
Time-of-Flight
Micropilot FMR57

The standard sensor for highest demands in bulk solids level measurement

  • Micropilot FMR57 aluminum housing with parabol antenna and universal flange ©Endress+Hauser
  • Micropilot FMR57 aluminum housing with horn antenna ©Endress+Hauser
  • Time-of-Flight measuring principle

  • Commissioning movie for Micropilot FMR5x free space radar and Levelflex FMP5x guided radar

  • Unique HistoROM data management concept for safe level measurement

  • Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

  • Micropilot with Advanced Dynamics offering more reliable measuring signals even in the case of turbulences

  • Micropilot FMR57 with Advanced Diagnostic functions offers build-up detection

  • Micropilot FMR57 aluminum housing with parabol antenna ©Endress+Hauser

Micropilot FMR57 is the sensor for the highest demands in bulk solids and best suited for measurements in high silos, bunkers or stockpiles. The parabolic antenna facilitates very small emitting angles and thus the measurement in slim silos. Micropilot free space radar is used for continuous, non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.

Lợi ích

  • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation

  • Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle

  • Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)

  • Reliable measurement even for changing product and process conditions

  • World's easiest proof test concept for SIL and WHG saves time and cost

Phạm vi ứng dụng

Horn or parabolic antenna. Thanks to the additional air purge connection even strongly dusting and build-up forming media do not present any problem.

  • Process connections: Thread or flange

  • Temperature: -40 to +400°C (–40 to 752°F)

  • Pressure: -1 to +16bar (-14.5 to +232psi)

  • Maximum measuring range: 70m (230ft)

  • K-band: 26GHz

  • International explosion protection certificates, SIL, 5-point linearity protocol

Tín năng và thông số kỹ thuật

Tài liệu / Tài liệu hướng dẫn / Phần mềm

Phụ kiện / Phụ tùng thay thế

Sản phẩm cũ / sản phẩm mới

Người tiền nhiệm: Prosonic S FDU96, Micropilot M FMR250

Liên hệ

Endress+Hauser Instruments International AG/ Asia Pacific Support Center
Unit 3, 1st Floor, CentrePoint Building 106 Nguyen Van Troi Street Phu Nhuan District Ho Chi Minh City Việt Nam
Điện thoại: +84 28 3842 0026
Gửi email

Thông tin liên quan

Trang web này sử dụng cookie. Để tiếp tục duyệt trang web, bạn sẽ đồng ý các điều khoản sử dụng cookie. Tìm hiểu thêm tại đây đóng lại

Vui lòng lựa chọn quốc gia / khu vực của bạn