Tổng quan về thông số kỹ thuật
-
Accuracy
up to 0.4 mm
-
Process temperature
-200°C...200°C
(-328°F...392°F) -
Process pressure absolute / max. overpressure limit
6 bar abs
-
Max. measurement distance
22 m (72 ft)
-
Main wetted parts
316L, AlloyC276, PTFE
Phạm vi ứng dụng
The intelligent tank gauge Proservo NMS83 is designed for high accuracy liquid level measurement in custody transfer and inventory control applications with NMi- and PTB-approvals. It meets all requirements for hygienic applications. It fulfills the exact demands of tank inventory management and loss control and is optimized in regards of total cost saving and safe operation.
For high accuracy custody transfer measurement in beer, whiskey, wine and sake.
Process connections: Flanges
Temperature: -200 to +200°C (-328 to +392°F)
Pressure: 0 to +6bar (0 to +87psi)
Maximum measuring range: 22m (72ft)
Accuracy: ±0.4mm (±0.02")
International explosion protection and custody transfer certificates, overfill prevention WHG, SIL
Lợi ích
-
Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety
-
Maximum reliability through accuracy up to ±0.4mm (± 0.02")
-
Developed according to international metrology recommendations such as OIML R85 and API MPMS
Local and country-specific certifications like NMi or PTB for custody transfer applications
-
Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols
-
Measurement of interfaces between up to three liquid layers, tank bottom, spot, and profile densities
Video
Lựa chọn Xpert
-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi

-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
Sản phẩm cũ
-
Measuring principle
Servo / Float Tank Gauging
-
Characteristic / Application
Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications -
Supply / Communication
85-264VAC
-
Ambient temperature
Standard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F) -
Process temperature
-200°C...200°C
(-328°F...392°F) -
Process pressure absolute
6 bar abs
-
Wetted parts
316L, AlloyC276, PTFE
-
Output
Outputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active) -
Certificates / Approvals
ATEX, FM, IEC Ex, NEPSI, EAC
-
Options
Redundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection -
Specialities
Custody transfer level measurement
Interface measurement
Spot density, density profile measurement -
Measuring range
22 m (72 ft)
-
Other approvals and certificates
EN 10204-3.1
NACE MR0175, MR0103
OIML, NMi, PTB
-
Measuring principle
Servo / Float Tank Gauging
-
Characteristic / Application
Servo Tank Gauging: High precision measurement for liquid level,
interface, spot density and density profile for hygienic applications -
Specialities
Custody transfer level measurement
Interface measurement
Spot density, density profile measurement -
Supply / Communication
85-264VAC
-
Accuracy
up to 0.4 mm
-
Ambient temperature
Standard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F) -
Process temperature
-200°C...200°C
(-328°F...392°F) -
Process pressure absolute / max. overpressure limit
6 bar abs
-
Main wetted parts
316L, AlloyC276, PTFE
-
Process connection
Flange:
DN80/3" / DN150/6" -
Max. measurement distance
22 m (72 ft)
-
Communication
Outputs:
Fieldbus: Modbus RS485, V1, HART
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/ active) -
Certificates / Approvals
ATEX, FM, IEC Ex, NEPSI, EAC
-
Safety approvals
Overfill protection WHG
SIL -
Design approvals
EN 10204-3.1
NACE MR0175, MR0103 -
Metrological approvals and certificates
OIML, NMi, PTB
-
Options
Redundant fieldbus
Weather protection cover
CIP (Cleaning in Place)
Relief valve
Gas purging nozzle connection
Pressure gauge
Cleaning nozzle connection -
Application limits
Stilling well or guide wires for turbulent
application
Recommend PTFE displacer for high
viscosity application
Interface measurement requires min. difference of 0.100 g/ml
between layers
Định cấu hình để tải xuống các bản vẽ CAD của sản phẩm này
Chọn theo đề xuất của chúng tôi
-
-- selected coding-- selected label99.999,00<%label%>
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Bạn muốn có nhiều lựa chọn hơn? Vui lòng sử dụng công cụ lựa chọn mã thiết bị để tiếp tục.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
-
Giá cho mỗi chi tiết
-
<%range%><%price%>
-
- Các add-on tùy chọn