Tổng quan về thông số kỹ thuật
-
Laser wavelength
Starter: 785 nm
Base Model: 532 nm, 785 nm, 1000 nm
Hybrid: 785 nm -
Spectral coverage
Starter:
300-3300 cm-1 (785 nm)
Base Model:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm)
Phạm vi ứng dụng
Adeptly harness the power of Raman spectroscopy with the Raman Rxn2 analyzer. Designed for use in analytical laboratories with model transfer capabilities, the Raman Rxn2 is heavily relied on for routine sample identification, support of R&D projects, early process development, and scale-up settings for in situ analysis. Available as a benchtop or on a mobile wheeled cart, the Raman Rxn2 offers location convenience and portability for process development laboratories.
Chemical: polymerization, extrusion monitoring, polymer blending, catalysis investigation
Pharmaceutical: reaction chemistry, yield crystallization, polymorph, blending, drying, granulations
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: zonal heterogeneity, fermentation
Lợi ích
Reliable real-time, in situ measurements
Intuitive, embedded control software via touchscreen or remote interface
Convenience of a single base unit supporting up to four probes
-
Sequential operation for fast analysis per channel and programmable channel interrogation
Converts acquired Raman spectra into process knowledge using built-in multivariate predictors
Suitable for outputs into hazardous area/classified environments
cGLP/cGMP compatible
Lựa chọn Extended
-
Sản phẩm cao cấp
- Chức năng cao và tiện lợi
Công nghệ vượt trội
Đơn giản

-
Sản phẩm chuyên dụng
- Dành cho các ứng dụng đòi hỏi cao
Công nghệ vượt trội
Đơn giản
Có thể thay đổi
Lựa chọn FLEX | Công nghệ vượt trội | Đơn giản |
---|---|---|
Lựa chọn Fundamental Đáp ứng nhu cầu đo lường cơ bản |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Lean Xử lý dễ dàng các quy trình cốt lõi |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Extended Tối ưu hóa quy trình bằng công nghệ tiên tiến |
Công nghệ vượt trội
|
Đơn giản
|
Lựa chọn Xpert Làm chủ các ứng dụng khó khăn nhất |
Công nghệ vượt trội
|
Đơn giản
Có thể thay đổi |
-
-
Thông tin kĩ thuật (TI)
Raman Rxn2 Technical Information
System design and specifications for the Raman Rxn2 analyzer - powered by Kaiser Raman technology
Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/09/2023
Cỡ tập tin:
762.8 KB
Tên tập tin:
TI01608CEN_0222.pdf
-
-
-
Hướng dẫn vận hành (BA)
Raman Rxn2 Operating Instructions
Commissioning, operation, and maintenance details for the Raman Rxn2 analyzer - powered by Kaiser Raman technology
Ngôn ngữ:
Tiếng Anh
Phiên bản:
06/10/2022
Cỡ tập tin:
5.4 MB
Tên tập tin:
BA02151CEN_0222.pdf
-
-
-
Hướng dẫn vận hành (BA)
Raman RunTime Operating Instructions
Commissioning, operation, and maintenance details for Raman RunTime software
Ngôn ngữ:
Tiếng Anh
Phiên bản:
16/11/2022
Cỡ tập tin:
4.7 MB
Tên tập tin:
BA02180CEN_0322.pdf
-
-
-
Hướng dẫn ngắn gọn (KA)
Raman Rxn2 Brief Operating Instructions
Quick start guide for the Raman Rxn2 analyzer - powered by Kaiser Raman technology
Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/09/2023
Cỡ tập tin:
1.1 MB
Tên tập tin:
KA01544CEN_0222.pdf
-
-
-
Hướng dẫn an toàn chống cháy (XA)
Raman Rxn2 Safety Instructions
Hazardous area certifications and installation instructions for the Raman Rxn2 analyzer - powered by Kaiser Raman technology
Ngôn ngữ:
Tiếng Anh
Phiên bản:
29/11/2022
Cỡ tập tin:
466 KB
Tên tập tin:
XA02700CEN_0222.pdf
-
-
-
PU (Ấn bản)
Lab-to-process monitoring & control in Life Sciences - Reliable measurement of bioprocess physical and chemical properties
A combined product list of analysis offerings from both Optical Analysis and Liquid Analysis for bioprocessing applications in the life science industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, bIO-Optic, Rxn-45 probe, Rxn-46 probe, Raman optic system for single use, Memosens CPS61E, Memosens COS81E, OUSBT66, Memosens CPS61E, Memosens CPS77E, Memosens CLS82E, OUSAF44, Memosens CPS11E, Memosens CLS16E, TOC Analyzer CA79, Liquiline transmitter platform, and Memobase software).
Ngôn ngữ:
Tiếng Anh
Phiên bản:
10/08/2022
Cỡ tập tin:
782.3 KB
Tên tập tin:
PU01484CEN_0122.pdf
-
-
-
PU (Ấn bản)
Advanced process and product control in fermentations - Raman spectroscopy for composition analysis in a lab or process
An overview of Raman spectroscopy analyzer systems (including the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45 probe), powered by Kaiser Raman technology, for fermentation compositional analysis in a lab or process applicable to biotechnology in the food & beverage industry.
Ngôn ngữ:
Tiếng Anh
Phiên bản:
03/03/2022
Cỡ tập tin:
726.2 KB
Tên tập tin:
PU01457CEN_0122.pdf
-
-
-
PU (Ấn bản)
Kaiser Raman technology and Sartorius BioPAT Spectro® collaboration Q&A - Scalable, real-time bioprocess monitoring solutions
A Q&A about how our Raman spectroscopy analyzer systems (including the Raman Rxn2 analyzer, Raman Rxn4 analyzer, and Rxn-46 probe), powered by Kaiser Raman technology, integrates with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for high throughput and single use (SUB) bioprocessingin the biopharmaceutical life science industry.
Ngôn ngữ:
Tiếng Anh
Phiên bản:
08/12/2021
Cỡ tập tin:
943.7 KB
Tên tập tin:
PU01446CEN_0121.pdf
-
-
-
PU (Ấn bản)
Raman calibration and verification kits - Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
An overview of the Raman calibration and verification kits for the bio multi optic / single use optic and the Raman flow assembly (includes the flow bench and flow cell). These kits are to be used in conjunction with the Rxn-10 probe and Raman Rxn2 analyzer for upstream and downstream bioprocessing (powered by Kaiser Raman technology).
Ngôn ngữ:
Tiếng Anh
Phiên bản:
01/06/2023
Cỡ tập tin:
1.2 MB
Tên tập tin:
PU01518CEN_0123.pdf
-
-
-
PU (Ấn bản)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the Life Science industry (featuring the Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, Rxn-45 probe, Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single use optic system / SUB, immersion optic , non-contact optic).
Ngôn ngữ:
Tiếng Anh
Phiên bản:
19/04/2022
Cỡ tập tin:
1.1 MB
Tên tập tin:
PU01447CEN_0222.pdf
-