Nhập ít nhất 2 ký tự để bắt đầu tìm kiếm.
  • Lịch sử

iTEMP TMT112
DIN rail temperature transmitter

Product picture temperature transmitter TMT112 ©Endress+Hauser
Product picture temperature transmitter TMT112 ©Endress+Hauser

Transformation of sensor signals into stable and standardized output signals for all industries.

Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from resistance thermometers (RTD) and thermocouples (TC), it also transfers resistance and voltage signals using HART® communication. Swift and easy operation, visualization and maintenance by PC using operating software. Space-saving DIN rail mounting according to IEC 60715 (housing width: 12.6 mm).

Chọn nhanh

Chọn theo đề xuất của chúng tôi
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

hoặc

Công cụ lựa chọn mã thiết bị

Tiếp tục lựa chọn từ tất cả tùy chọn có thể
  • Lợi ích

    • Universal settings with HART®-protocol

    • High accuracy in total ambient temperature range

    • Fault signal on sensor break or short circuit, NAMUR NE 43 compliant

    • EMC to NAMUR NE 21, CE

    • Ex-Certification: ATEX Ex, CSA IS, FM IS

    • Galvanic isolation

  • Phạm vi ứng dụng

    • Temperature transmitter with HART® -Protocol for converting various input signals into a scalable 4 to 20 mA analog output signal

    Input:

    • Resistance thermometer (RTD)

    • Thermocouple (TC)

    • Resistance transmitter (Ω)

    • Voltage transmitter (mV)

    • HART® -Protocol for...

Tín năng và thông số kỹ thuật

Quay lại

Details

  • Measuring principle

    Rail transmitter

  • Input

    1 x RTD, TC, Ohm, mV

  • Output

    1 x analog 4...20 mA

  • Auxiliary power supply

    12...35 V DC (standard-version)

    12...30 V DC (Ex-version)

  • Communication

    HART

  • Installation

    DIN rail

  • Accuracy

    (Pt100, -50...200 °C) <= 0,2 K

    (Pt100, -58...392 °F) <= 0,4 °F

  • Galvanic isolation

    yes

  • Certification

    UL rec. Com

    FM IS,NI,Class I,Div.1+2,Group ABCD

    CSA IS,NI,Class I,Div.1+2,Group ABCD

    ATEX II2(1)G EEx ia IIC T4/T5/T6

    ATEX II3G Ex nA IIC T6

    CSA General Purpose

Tài liệu / Tài liệu hướng dẫn / Phần mềm