Radar measurement
Micropilot FMR540

Micropilot FMR540 horn antenna ©Endress+Hauser
Micropilot FMR540 parabolic antenna ©Endress+Hauser

Time-of-Flight measuring principle

Horn antenna and parabolic antenna for custody transfer applications

Micropilot FMR540 is used for custody transfer and inventory control applications with NMi- and PTB-approvals and meets the requirements according to OIML R85 and API 3.1B. FMR540 with parabolic antenna is particularly suited for free space applications up to 40m and with horn antenna for free space applications that disallow the use of a parabolic antenna due to tank/nozzle geometry. Cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply.

  • Lợi ích

    • Better than 1mm accuracy

    • National approvals (NMi, PTB) for custody transfer

    • Applicable as stand-alone system or integrated into tank gauging systems via the Tank Side Monitor NRF590

    • Cost-effective and simple installation via 4-wire cable with HART and 24 V...

  • Phạm vi ứng dụng

    Parabolic antenna suited for free space applications up to 40m offers high beam focusing for applications with nozzle situated close to tank wall, 4"/DN100 horn antenna suited for free space applications.

    • Process connection: Flange

    • Temperature: -40 to +...

Tín năng và thông số kỹ thuật

Quay lại

Details

  • Measuring principle

    Level radar

  • Characteristic / Application

    Horn antenna:
    High precision measurement for for storage tanks up to 20 m (65ft)

    Parabolic antenna:
    High precision measurement for free space applications up to 40 m (131 ft)

  • Supply / Communication

    4-wire (HART)

  • Frequency

    K-band (~26 GHz)

  • Accuracy

    +/- 1 mm

  • Ambient temperature

    Standard:
    -40°C...80°C
    (-40°F...176°F)
    For calibration to regulatory standards:
    -25°C...60°C
    (-13°F...131°F)

  • Process temperature

    -40°C...200°C
    (-40°F...392°F)

  • Process pressure absolute / max. overpressure limit

    Horn: Vacuum...16 bar (232 psi)
    Parabolic: Vacuum...6 bar (87 psi)
    Use of UNIflange: Vacuum...1 bar (14.5 psi)

  • Main wetted parts

    316L

  • Process connection

    Horn Antenna: DN100, DN150 Flange
    UNIFlange DN150, DN200, DN250
    Parabolic antenna: UNIflange with Top Target
    positioner DN200, DN250

    For dk value < 1.9, contact Endress+Hauser

  • Application

  • Max. measurement distance

  • Radar_Mediengruppe_en.jpg
  • Communication

    4...20 mA HART

  • Certificates / Approvals

    ATEX, FM, CSA, IEC Ex, NEPSI

  • Safety approvals

    Overfill prevention WHG

  • Application limits

    Maximum measuring range is dependent on the tank form and/or application


    Strong condensate or build-up formation

    FMR53x
    Existing stilling wells with non-ideal measuring conditions