The Deltabar FMD77 differential pressure transmitter with metal sensor uses a one-sided diaphragm seal or diaphragm seals on both sides with a capillary on the low pressure side. Typically used in the process industry for continuous level measurement in liquids. The integrated HistoROM data module makes the management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety applications.
-
Lợi ích
Large variety of different process connections and membrane materials
Highest safety due to gas-tight feedthrough with capabilities up to SIL2/3, certified to
IEC 61508New TempC Membrane minimizes influences of ambient and process temperature...
-
Phạm vi ứng dụng
For level, volume or mass measurement in liquids.
Process connections: Threads and flanges
Temperature: -70 to +400°C (-94 to +752°F)
Measuring ranges: +100mbar to +16bar (+1.5 to +240psi)
Accuracy: ±0.075%
International explosion protection...
Tài liệu / Tài liệu hướng dẫn / Phần mềm
-
Deltabar S
PMD75, FMD77, FMD78
Technical Information
Differential pressure transmitter, used for measuring flow rate, level,
pressure and differential pressure.Technical Information (TI) -
Cerabar S /Deltabar S /Deltapilot S
Description of device
functions
PROFIBUS PA
V04.01.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S, Description of device functions
FOUNDATION Fieldbus
V 04.00.zz
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure
transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar S / Deltabar S / Deltapilot S
HART V02.30.zz
Description of Instrument Functions
Cerabar S PMC71, PMP71, PMP75 Pressure transmitter
Deltabar S FMD77, FMD78, PMD75 Differential pressure transmitter
Deltapilot S FMB70 Hydrostatic pressure transmitterOperating Instruction (BA) -
Deltabar S FMD77, FMD78, PMD75
HART V02.30.zz
Operating Instructions
Differential pressure transmitter with metal sensors
Operating Instruction (BA) -
Deltabar S FMD77/78; PMD75
FOUNDATION Fieldbus (V 04.00.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusOperating Instruction (BA) -
Deltabar S FMD77/78; PMD75
PROFIBUS PA (V 04.01.zz)
Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communication via
PROFIBUS PAOperating Instruction (BA) -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential
pressure transmitter
Deltapilot S - hydrostatic transmitterShort Instruction (KA)12/14Tiếng Đức , Tiếng Anh -
Cerabar S, Deltabar S, Deltapilot S
Cerabar S, Deltabar S, Deltapilot S
Process pressure measurement/differntial pressure
measurement/hydrostatic level measurement
V 04.00.zzShort Instruction (KA)12/14Tiếng Đức , Tiếng Anh -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
PROFIBUS PAShort Instruction (KA)04/17Tiếng Anh -
Deltabar S FMD77/78; PMD75
Brief Operating Instructions
Differential pressure transmitter with ceramic and silicon sensors
Overload-resistant and function-monitored
Communicationvia
FOUNDATION FieldbusShort Instruction (KA)04/17Tiếng Anh -
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
Austausch der Elektronik am Cerabar S, Deltabar S, Deltapilot S
Exchange of electronics on Cerabar S, Deltabar S, and Deltapilot S
FMB70-, FMD72-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-,
PMP71-, PMP72-, PMP75-Short Instruction (KA)04/12Tiếng Đức , Tiếng Anh -
Deltabar S FMD77, FMD78, PMD75
HART
Brief Operating Instructions
Differential pressure transmitter with metal sensors
Short Instruction (KA)03/18Tiếng Anh -
Cerabar S, Deltabar S, Deltapilot S
Cearabar S - pressure transmitter
Deltabar S - differential pressure transmitter
Deltapilot S - hydrostatic level measurement
V02.30.zzShort Instruction (KA)02/18Tiếng Đức , Tiếng Anh -
Aluminum housing T15
Installation instruction
Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Mounting set for housing T14/15
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Push button housing
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Aluminum housing T14
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Electronics
Installation Instructions
Cerabar S PMC71, PMP71, PMP75, Deltabar S FMD77, FMD78, PMD75, Deltabar
FMD71, FMD72, Deltapilot S FMB70Mounting Instruction (EA) -
Terminal module
Installation Instructions
Cerabar S PMC71, PMP71, PMP75, Deltabar S FMD77, FMD78, PMD75, Deltabar
FMD71, FMD72, Deltapilot S FMB70Mounting Instruction (EA) -
Harting plug HAN7D
Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
Mounting Instruction (EA) -
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
Mounting Instruction (EA) -
Feed-through and adapter for T15
Installation Instruction
Cerabar S, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Installation instruction - Ground terminal T14/T15/T17, F30/F31
Cerabar S, Deltabar S, Deltabar, Cerabar M, Deltabar M, Deltapilot M
Mounting Instruction (EA) -
Display
Installation Instruction
Cerabar S, Deltabar, Deltabar S, Deltapilot S
Mounting Instruction (EA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
FM Control Drawing
960006696 F
IS, NI, DIPEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
Ex d IIC T6...T4 Gb
IECEx KEM 10.0031Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1 G Ex ia IIC T6...T4 Ga
II 1 D Ex ia IIIC T85°C Da
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
IECEx:
Ex ia IIC T6...T4 Ga/Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
XA01064P-B
NIEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T4 Ga/Gb
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Cerabar S PMC71, PMP71, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA Control Drawing
960006717 G
ISEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 1/2 D Ex ia IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Cerabar S PMP71, PMP75, Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
960006753 C
IS+XP, NI, DIPEx Safety Instructions (XA) -
Safety Instructions
Deltabar S FMD77, FMD78, PMD75
CSA Control Drawing
960008823 D
XPEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex d IIC T4/T6 Gb
GYJ15.1272XEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex nA IIC T6 Gc
GYJ14.1447 (NEPSI)Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
Ga/Gb Ex ia IIC T6...T4
Ex ia IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
CSA Control Drawing
960006403 H
IS + XPEx Safety Instructions (XA) -
Deltabar S PMD70, PMD75, FMD77, FMD78
KEMA 03 ATEX 1561
II 1/2 D
Protection: Ex tD A20 IP67 T105°CEx Safety Instructions (XA) -
Cerabar S PMP71, PMP72, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960006752 F
Drawing Type: Control DrawingEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
1Ex db IIC T6...T4 Gb
1Ex db IIC T6...T1 Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/3 D Ex ta/tc IIIC T85°C Da/Dc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 2 G Ex db IIC T6...T4/T1 Gb
IECEx:
Ex db IIC T6...T4/T1 Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T4/T6 Ga/Gb
GYJ15.1274X (NEPSI)Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
Ga/Gb Ex ia IIC T6...T4
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
XA01071P-B
XP, DIP, NIEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Ex ia IIC T6...T4 Ga/Gb
IECEx KEM06.0011Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 3 G Ex nA IIC T6 Gc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 2 G Ex d IIC T6...T4 Gb
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex d IIC T Gb
TÜV 13.0902X (INMETRO)Ex Safety Instructions (XA) -
Safety Instructions
Cerabar S PMC71, PMP71, PMP72, PMP75
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM Control Drawing
960006703 E
ISEx Safety Instructions (XA) -
Deltabar S PMD70, PMD75, FMD77, FMD78
KEMA 03 ATEX 1561
II 1/3 D
Protection: Ex tD A20 IP67 T85°CEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77/78
CSA Control Drawing
960006697 I
ISEx Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD75, FMD77, FMD78
FM Control Drawing
960006404 C
IS+XP, NI, DIPEx Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
EAC:
Ex ta IIIC T85°C Da / Ex tc IIIC T85°C Dc
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Deltabar S PMD75, FMD77, FMD78
ATEX:
II 1/2 D Ex ta/tb IIIC T85°C Da/Db
Safety Instructions
Differential Pressure Transmitter
Ex Safety Instructions (XA) -
Safety Instructions
Deltabar S PMD70, PMD75, FMD77, FMD78
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ta IIIC T130°C Da/Db (HART)
Ex ta IIIC T105°C Da/Db (PA, FF)
TÜV 13.2007 (INMETRO)Ex Safety Instructions (XA) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
Allgemeine bauaufsichtliche Zulassung Z-65.11-384
Certificate (ZE) -
RFID TAG
Certificate/Declaration of Conformity
ATEX:
II 2 G Ex ia IIC T6 Gb
II 2 D Ex ia IIIC T80°C Db;
IECEx:
Ex ia IIC T6 Gb
Ex ia IIIC T80°C Db
IECEx EPS 15.0042X; EPS 15 ATEX 1 1011 XCertificate (ZE) -
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960008823 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960534-2098 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
FM
Drawing No.: 960006703 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 B
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960006403 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMP71, PMP72, PMP75, FMD77, FMD78, PMD75
FM
Drawing No.: 960006753 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP72, PMP75, FMD76, FMD77, FMD78,
PMD70, PMD75
CSA
Drawing No.: 960006717 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960006697 E
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD77, FMD78, PMD75
FM
Drawing No.: 960006404 A
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMP71, PMP72, PMP75, FMD77, FMD78, PMD75
CSA
Drawing No.: 960006752 A
Drawing Type: Control Drawing
PROFIBUS PA, FOUNDATION FieldbusCertificate FM/CSA (ZD) -
Cerabar S PMP71, PMP72, PMP75
Deltabar S FMD77, FMD78, PMD75
CSA
Drawing No.: 960006752 C
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
FM
Drawing No.: 960534-1092 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltabar S FMD76, FMD77, FMD78, PMD70, PMD75
CSA
Drawing No.: 960534-2092 D
Drawing Type: Control Drawing
4...20 mA HARTCertificate FM/CSA (ZD) -
Cerabar S, Deltabar S PMC71, PMP71, PMP75, FMD76, FMD77, FMD78, PMD70,
PMD75
CSA
Drawing No.: 960006717 D
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Cerabar S, Cerabar M, Deltabar S
PMC71, PMP72, PMP75, PMP55,
FMD77, FMD78
Erklärung zur Druckgeräterichtlinie
Declaration to Pressure Equipment Directive
Déclaration relative à la Directive Equipements sous PressionSpecial Documentation (SD) -
Functional Safety Manual
Deltabar S PMD75, FMD77, FMD78
Pressure and Differential Pressure, Level and Flow Measurement
with Output Signal 4...20 mASpecial Documentation (SD) -
Deltabar S PMD70/75, FMD76/77/78
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Pressure Equipment Directive (PED)
Pressure measurement
Special Documentation
Pressure Equipment Directive (PED)
Special Documentation (SD) -
RFID TAG
Special Documentation
RFID TAG
Special DocumentationSpecial Documentation (SD) -
Interoperability Statement: Deltabar S (Evolution), FOUNDATION fieldbus
Endress+Hauser field device has been tested with Rockwell Automation
Integrated Architecture-based host system Allen-Bradley ControlLogix.
Deltabar S (Evolution), FOUNDATION fieldbus Pressure Transmitter, Device
Revision: 5, DD Revision: 1, Device ID: 0x1009, Software Revision: 2.00Special Documentation (SD) -
Mechanical accessories for pressure measuring devices
Pressure measurement
Special Documentation
Mechanical accessories for pressure measuring devices
Special Documentation (SD) -
Cerabar S PMC71, PMP71, PMP75,
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Manufacturer Information for users regarding softwareupdates (NE53)
Software version V03.00.00 / DevRev 6 FOUNDATION FIELDBUS
Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Deltabar S: FMD77, FMD78, PMD75
Manufacturer information for users regarding software updates (NE53)
Softwareversion V02.20.00 HART
Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V02.11.00 HART
Manufacturer Information (MI) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version V4.00.10 PROFIBUS PA
Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding softwareupdates (NE53)
Software version V04.01.00 PA
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Deltabar S: PMD75, FMD77, FMD78,
Cerabar S: PMC71, PMP71, PMP75,
Deltapilot S: FMB70
Manufacturer information for users regarding software updates (NE53)
Firmware V02.30.06, HART
Manufacturer Information (MI) -
Deltabar S PMD70, PMD75, FMD76, FMD77, FMD78
Cerabar S PMC71, PMP71, PMP75
Manufacturer Information for users regarding software updates (NE53)
Software version 02.10.40
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Deltabar S: FMD76, FMD77, FMD78, PMD70, PMD75
Manufacturer information for users regarding software updates (NE53)
Software version V04.00.01 FF
Manufacturer Information (MI) -
Control Engineering marzec 2006
Akredytowana kalibracja przetworników ci&
347;nienia i ró
&
380;nicy ci&
347;nie&
324;Publications (PU)09/08Người Ba Lan -
Nap&
281;dy i Sterowanie marzec 2007
Akredytowana kalibracja przetworników
ci&
347;nienia i ró&
380;nicy ci&
347;nie&
324;Publications (PU)08/09Người Ba Lan -
压力测量
用于过程压力、差压、液位和流量测量的专业仪表
Fields of Activities (FA)09/15Tiếng Trung Quốc -
Basınç Ölçümü
Proses basıncı, fark basınç, seviye ve akış için güçlü enstrümanlar
Fields of Activities (FA)05/15Tiếng Thổ Nhĩ Kỳ -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des
solides en vracFields of Activities (FA)03/19fr -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17Tiếng Anh -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)03/17Tiếng Tây Ban Nha -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17Tiếng Đức -
Pressure measurement
American version: Powerful instruments for process pressure,
differential pressure, level
and flowFields of Activities (FA)03/17Tiếng Anh -
Misura della pressione
Potenti strumenti per la misura della pressione di processo, pressione
differenziale,
livello e portataFields of Activities (FA)03/17Tiếng Ý -
Pressure measurement
Powerful instruments for process pressure, differential pressure, level
and flowFields of Activities (FA)03/17Tiếng Anh -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17Tiếng Anh -
Mesure de pression
Appareils de mesure pour la pression de process, la pression
différentielle, le niveau et le débitFields of Activities (FA)03/17fr -
Catálogo Medición de Presión
Instrumentos para la medición de presión, presión diferencial, nivel y
caudal de procesoFields of Activities (FA)03/17Tiếng Tây Ban Nha -
Druckmesstechnik
Leistungsfähige Messgeräte für Prozessdruck, Differenzdruck, Füllstand
und DurchflussFields of Activities (FA)03/17Tiếng Đức -
Pomiar ciśnienia
Potężna aparatura do pomiaru
ciśnienia procesowego, różnicy
ciśnień, poziomu i przepływuFields of Activities (FA)03/14Người Ba Lan -
Selection Guide
Continuous level measurement in liquids and bulk solids
Selection and engineering guide for the process industry
Competence Brochure (CP)12/17Tiếng Anh -
粉体液体の連続レベル測定
レベル計選定ガイド
Competence Brochure (CP)12/17Tiếng Nhật -
Mesure de niveau continue dans les liquides et les solides
Sélection et configuration pour l'industrie des process
Competence Brochure (CP)12/17fr -
Selection Guide, Auswahlhilfe.
Kontinuierliche Füllstandmessung in Flüssigkeiten und Schüttgütern
Auswahl- und Projektierungshilfe für die Prozessindustrie
Competence Brochure (CP)11/17Tiếng Đức -
Komplettpaket Druckmesstechnik
Ein Ansprechpartner - spart Zeit und reduziert Kosten
Competence Brochure (CP)05/15Tiếng Đức -
Непрерывное измерение уровня жидких и сыпучих продуктов
Руководство по подбору обоурдования
Competence Brochure (CP)03/13Tiếng Nga -
American version: Continuous level measurement in liquids and bulk
solids
American version: Selection and engineering guide for the process
industryCompetence Brochure (CP)Tiếng Anh -
L’automatisation des process vaut son pesant d’or
Memosens Les sondes de pH améliorent les process chez Agnico Eagle
Case Studies (CS)07/16fr -
Process automation worth its weight in gold
Memosens pH sensors improve processes at Agnico Eagle
Case Studies (CS)07/16Tiếng Anh -
Prozessautomatisierung, die Gold wert ist
Memosens pH-Sensoren verbessern Prozesse bei Agnico Eagle
Case Studies (CS)07/16Tiếng Đức -
Ofenreparatur mit Mehrwert
Messtechnik für eine effizientere Grobblechveredelung
Wenn
s heiß hergeht, wie z. B. beim
Härten, Anlassen und Vergüten von
Grobblechen in Durchlaufglühöfen,
ist robuste Messtechnik gefragt.
Der Ofen der voestalpine Grobblech GmbH (voestalpine) hatte eine
Reparatur nötig, durch die neben der Erhöhung des Durchsatzes auch
der Energie- und Gasverbrauch reduziert
werden sollte. Dass Verbrennungsluft
wie auch Mischgas im bestmöglichen
Verhältnis zugeführt werden, stellt
heute ein komplettes Paket an Feldinstrumenten
von Endress+Hauser
sicher.Case Studies (CS)06/10Tiếng Đức -
Patented TempC Membrane
Best pressure measurement with diaphragm seals
Innovations (IN)08/17Tiếng Anh -
Patentierte TempC Membran
Ein Garant für beste Messperformance
Innovations (IN)01/18Tiếng Đức -
Deltabar S Differential Pressure Transmitter via
FOUNDATION fieldbus to the PlantPAx Process Automation System
System using a 1757-FFLD or FFLDC
Integration DocumentSystem Partner (SP)03/12Tiếng Anh -
Deltabar S Transmitter via PROFIBUS PA to the PlantPAx Process
Automation System
System using a 1788HP-EN2PAR Linking Device
Integration DocumentSystem Partner (SP)01/13Tiếng Anh -
Deltabar S Transmitter via HART to the PlantPAx Process Automation
System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09Tiếng Anh -
GSD Single, GSD_EH_PA_PR_Deltabar_0x1542_V03_00_10_PALIB, 14.04.2014 (Pre
ssure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)3.00.10Language neutral -
GSD Single, GSD_EH_PA_PR_DeltabarS_0x1542_0x03_0x01_PALIB, 19.05.2014 (Pr
essure, Deltabar S, 0x1542)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_60, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x17_0x01, 23.04.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.1, 9.0.1.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x15_0x04, 31.03.2014 (Pressure,
Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x05_0x01_FFLIB_ITK4_61, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.61Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x16_0x03, 28.05.2015 (Pressure, Deltabar S)
HART,
PDM Version: 6.1, 8.1, 8.2.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x14_0x02, 27.02.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Other, EDD_FF_PR_DeltabarS_0x1009b_0x07_0x02, 12.05.2014 (Pressure, D
eltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x01_FFLIB_ITK5_01, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_PR_DeltabarS_0x1009b_0x06_0x03_FFLIB_ITK5_20, 09.11.201
6 (Pressure, Deltabar S, 0
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x02, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP3, 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_0_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.0, 10.1, 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x01_0x01, 04.01.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x0A_0x01, 06.11.2018 (Pressure, Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 10.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_PR_DeltabarS_0x1542_0x03_0x02, 17.08.2015 (Pressure, Deltabar S)
PROFIBUS PA,
PDM Version: 6.0 SP5, 6.1, 8.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_PR_DeltabarS_0x0017_0x15_0x04, 21.08.2019 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_PR_DeltabarS_0x0017_0x15_0x07, 25.02.2015 (Pressure,
Deltabar S, 0x0017)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_5_FF_PR_DeltabarS_0x1009b_0x07_0x02, 11.04.2017 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
AMS Version: 11.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, DeltabarS_xMD7x_FF_FW4_00_zz_Dev_Rev_7, 08.07.2019 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_PMx7x_FF_V3_00_xx_DevRev6, 08.07.2019 (Pressure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltabarS_xMD7x_PA_FW4_01_zz_Dev_Rev_3, 08.07.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V03_00_10, 08.07.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_PA_V4_00_xx, 08.07.2019 (Pressure, Deltabar S, 0x1542)
PROFIBUS PA,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW_2_30_zz_Dev_Rev_23, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.06.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
PACTware Version: 5.0 SP4
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_HART_FW2_20_zz_Dev_Rev_22, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Plant Resource Manager Version: R3.11, R3.12Device Type Manager (DTM)1.4.189.51Language neutral -
DTM Single, DeltabarS_xMD7x_V01_00, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V02_10_xx, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00
Plant Resource Manager Version: R3.11Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, DeltabarS_xMD7x_V02_00, 08.07.2019 (Pressure, Deltabar S, 0x0017)
HART,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_HART_Package_Pressure_1_08_00, 22.07.2015 (Pressur
e)
HART,
Plant Resource Manager Version: R3.05, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Library, PRM_FF_Package_Pressure_1_05_00, 29.05.2018 (Pressure)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02Faceplate1.05.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x16_0x04, 31.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.12Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_PR_DeltabarS_0x1009b_0x07_0x02, 07.04.2014 (Pres
sure, Deltabar S, 0x1009b)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_PR_DeltabarS_0x0017_0x17_0x02, 25.01.2018 (Pressure, Deltabar S, 0x0017)
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD76-, FMD77-, FMD78-, PMC71-, PMD70-, PMD75-, PMP71-, PMP72-, PMP75-
Declaration Number: HE_00729_01.17Manufacturer DeclarationTiếng Đức , Tiếng Anh -
Deltabar S
Product Code: FMD77-
Declaration Number: HE_00579_01.17
Manufacturer Specification: RoHSManufacturer DeclarationTiếng Trung Quốc -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_02.19
Manufacturer Specification: Food hygieneManufacturer DeclarationTiếng Anh -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_01.19
Manufacturer Specification: Food hygieneManufacturer DeclarationTiếng Anh -
Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PMP71-, PMP55-, PMP51-, PMP23-, PMD75-, PMD55-, FMD78-, FMD77-, FMD72-, FMB70-, FMB52-, FMB51-, FMB50-
Declaration Number: HE_01110_03.19
Manufacturer Specification: Food hygieneManufacturer DeclarationTiếng Anh -
Cerabar S, Deltabar, Deltabar S
Product Code: FMD77-, FMD78-, PMD75B-, PMP71-, PMP75-
Declaration Number: HE_00999_01.18
Manufacturer Specification: Operating conditionsManufacturer DeclarationTiếng Anh -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Declaration Number: EC_00250_03.16EU DeclarationTiếng Đức , Tiếng Anh , fr -
Deltabar S
Product Code: PMD75-, FMD78-, FMD77-
Declaration Number: EC_00514_02.17EU DeclarationTiếng Đức , Tiếng Anh , fr -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Declaration Number: EC_00516_02.17EU DeclarationTiếng Đức , Tiếng Anh , fr -
Deltabar S
Product Code: FMD78-, PMD75-, FMD77-
Declaration Number: EC_00517_02.17EU DeclarationTiếng Đức , Tiếng Anh , fr -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
EU DeclarationTiếng Đức , Tiếng Anh , fr -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Declaration Number: EC_00515_02.17EU DeclarationTiếng Đức , Tiếng Anh , fr -
Deltabar S
Product Code: FMD77-, FMD78-
Declaration Number: EC_00513_03.17EU DeclarationTiếng Đức , Tiếng Anh , fr -
Deltabar M, Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD55-, PMD70-, PMD75-
Region/Country: Russia
Approval Agency: Rostekhnadzor
Approval Number: 01-TY-00477-2014MiscellaneousTiếng Nga -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: China
Approval Agency: ACMA
Approval Number: EC11012AMiscellaneousTiếng Anh -
Waterpilot, Deltapilot S, Deltapilot M, Deltapilot, Deltabar S, Deltabar M, Deltabar, Ceraphant T, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PTP31B-, PTC31B-, PTC31-, PMP75-, PMP71-, PMP55-, PMP51-, PMP23-, PMP21-, PMP11-, PMD75-, PMD55-, PMC71-, PMC51-, PMC21-, PMC131-, PMC11-, FMX21-, FMX167-, FMD78-, FMD77-, FMB70-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: Russia (TR CU), Russia (Declaration of Conformity)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05287MiscellaneousTiếng Nga -
Deltabar, Deltabar M, Deltabar S
Product Code: FMD71-, FMD72-, FMD77-, FMD78-, PMD55-, PMD75-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 127MiscellaneousTiếng Nga -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex dExplosion ProtectionTiếng Bồ Đào Nha -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 G
Protection: Ex d [ia] IIC T6...T3 Gb, Ex db IIC T6...T1 GbExplosion ProtectionTiếng Anh -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionTiếng Anh , Tiếng Trung Quốc -
Deltabar S
Product Code: PMD75-, FMD78-, FMD77-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 G
Protection: Ex d IIC T6 GbExplosion ProtectionTiếng Anh -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionTiếng Anh -
Cerabar S, Deltabar S
Product Code: PMP71-, PMP75-, PMC71-, FMD78-, PMD75-, FMD77-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex dExplosion ProtectionTiếng Bồ Đào Nha -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex ta/tc, Ex ia, Ex dExplosion ProtectionTiếng Nga -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Region/Country: International, International (IECEx)
Approval Agency: DEKRA
Protection: Ex d IIC T6Explosion ProtectionTiếng Anh -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1,2/A,B,C,D,F,G/
Protection: DIP, IS, NIExplosion ProtectionTiếng Anh -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMP71-, PMD75-, PMP75-, PMP72-
Region/Country: India
Approval Agency: CC(O)E
Protection: Ex iaExplosion ProtectionTiếng Anh -
Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: Canada, USA
Approval Agency: CSA
Category: II,III/1/E,F,G, I,II,III/1/B,C,D,E,F T6, I,II,III/1/A,B,C,D,E,F,G T6, I/2/A,B,C,D
Protection: XP/IS, XP, NI, IS/NI/DIP, DIPExplosion ProtectionTiếng Anh -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1/A,B,C,D,E,F,G/T6
Protection: XP/NI/DIP, XP/ISExplosion ProtectionTiếng Anh -
Deltabar S
Product Code: PMD75-, FMD78-, FMD77-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 2 G, II 1/2 G
Protection: Ex d IIC T6, Ex ia IIC T6Explosion ProtectionTiếng Anh -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex d [ia] IIC T6...T3 Gb, Ex db IIC T6...T1 GbExplosion ProtectionTiếng Anh -
Deltabar S
Product Code: PMD75-, PMD70-, FMD78-, FMD77-, FMD76-
Region/Country: Europe (ATEX)
Approval Agency: KEMA
Category: II 1 D, II 1 G
Protection: Ex ia IIC T6 Ga/GbExplosion ProtectionTiếng Anh -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMD75-, PMP71-, PMP72-, PMP75-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex ia IIC T6...T2Explosion ProtectionTiếng Đức , Tiếng Anh -
Cerabar S, Deltabar S, Deltapilot S
Product Code: PMP75-, PMP71-, PMD75-, PMC71-, FMD78-, FMD77-, FMB70-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 1/3 D, II 1/2 G, II 1/2 D, II 2 G
Protection: Ex ta/tb IIIC Txxx°C Da/Db, Ex ia IIIC Txxx°C Da/Db, Ex ia IIC T6 Ga/GbExplosion ProtectionTiếng Anh -
Deltabar S
Product Code: FMD77-, FMD78-, PMD75-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex d IIC T6 GbExplosion ProtectionTiếng Anh , Tiếng Trung Quốc -
Cerabar S, Deltabar M, Deltabar S
Product Code: PMP75-, PMP72-, PMP71-, PMD75-, PMD70-, PMD55-, PMC71-, FMD78-, FMD77-, FMD76-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d, Ex ia, Ex iaD 20, Ex taExplosion ProtectionTiếng Nga -
Cerabar S, Deltabar S, Deltapilot S
Product Code: PMP71-, PMP75-, PMD75-, FMD78-, FMD77-, PMD70-, FMB70-, PMC71-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex iaExplosion ProtectionTiếng Bồ Đào Nha -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMD75-, PMP71-, PMP72-, PMP75-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex d IIC T6...T2, Ex ia IIC T6...T2Explosion ProtectionTiếng Đức , Tiếng Anh -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.11-384Overfill PreventionTiếng Đức -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.02Fieldbus ConformanceTiếng Anh -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 07, DD-ITK 6.10Fieldbus ConformanceTiếng Anh -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.20Fieldbus ConformanceTiếng Anh -
Product Family: Deltabar S
Product Code: FMD76-, FMD78-, PMD75-, FMD77-, PMD70-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 06, DD-ITK 5.01Fieldbus ConformanceTiếng Anh -
Waterpilot, Deltabar S, Cerabar S, Cerabar M, Deltapilot S, Deltabar M, Deltapilot M, Deltabar, Ceraphant T, Ceraphant, Cerabar T, Cerabar
Product Code: PTP35-, FMD78-, PMP71-, PMD75-, FMD77-, PMD70-, PMP75-, PMP51-, PMP55-, PMC71-, FMD76-, FMB53-, FMB70-, PMC51-, PMD55-, FMB50-, FMD72-, FMX21-, PTP33B-, PTP31-, PTC31-, PMP23-, PMP135-, PMP11-, PMC131-, FMX167-, FMD71-
Approval Agency: TÜVPressure EquipmentTiếng Đức , Tiếng Anh -
Deltabar S
Product Code: FMD76-, FMD77-, FMD78-, PMD70-, PMD75-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentTiếng Anh -
Levelflex, Deltabar S, Cerabar S, Cerabar M, Deltabar M, Ceraphant T, Ceraphant, Cerabar T, Cerabar
Product Code: PTP31B-, FMP54-, FMD78-, PMP71-, PMD75-, FMD77-, PMP75-, PMP51-, PMP55-, PMD55-, PTP31-, PMP21-, PMP135-, PMP131-
Approval Agency: TÜVPressure EquipmentTiếng Đức , Tiếng Anh -
Deltabar, Deltabar M, Deltabar S
Product Code: FMD71-, FMD72-, FMD77-, FMD78-, PMD55-, PMD75-
Region/Country: Belarus
Approval Agency: BEL
Approval Number: 9770MetrologyTiếng Nga -
Deltabar M, Deltabar S
Product Code: FMD77-, FMD78-, PMD55-
Region/Country:
Approval Agency: MSST
Approval Number: 2214MetrologyTiếng Nga -
Cerabar M, Cerabar S, Cerabar T, Deltabar, Deltabar S
Product Code: PMP75-, PMP71-, PMP55-, PMP51-, PMP48-, PMP46-, PMP45-, PMP41-, PMP135-, PMP131-, PMD55B-, PMC71-, PMC51-, PMC45-, PMC41-, PMC131-, FMD78-, FMD77-, FMD76-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.30.004.A NO 36496/1MetrologyTiếng Nga -
Deltabar M, Deltabar S
Product Code: FMD77-, FMD78-, PMD55-, PMD75-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.30.004.A NO 71578MetrologyTiếng Nga -
Cerabar, Cerabar S, Deltabar S, Deltapilot S
Product Code: FMB70-, FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)Tiếng Anh -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Region/Country: International
Approval Agency: RM RSMarineTiếng Nga -
Cerabar S, Deltabar S
Product Code: FMD77-, FMD78-, PMC71-, PMD75-, PMP71-, PMP75-
Approval Agency: RM RSMarineTiếng Nga
Phụ kiện / Phụ tùng thay thế
-
-
Nr 12 Order code 52020440
Mounting set housing T14/T15 / sensor
Consists of: 2x O-ring 45.69x2.62 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 12 Order code 71020596
Mounting set housing T17 / sensor
Consists of: 2x O-ring 45.62x69x2.62 EPDM. 1x profile gasket 51.4x57.2x1.6 EPDM. Retaining ring, plastics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 13 Order code 52022418
Push button housing, PA/FF
Consists of: push button, cover + screws. Usage: external operation, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 13 Order code 52022419
Push button housing, HART, version 1
Consists of: push button, cover + screws. Colour light grey. Usage: external operation, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 13 Order code 52024110
Push button housing, HART, version 2
Consists of: push button, cover + screws. Colour dark grey. Usage: external operation, FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75.
-
-
-
Nr 15 Order code 52020760
Cable gland M20, gasket
Consists of: cable gland M20. O-ring 18.72x2.62 VMQ. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020761
Cable entry G1/2, gasket, adapter
Consists of: gasket 18.72x2.51 NBR. Adapter M20 > G1/2. O-ring 18.77x1.78 NBR. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 15 Order code 52020762
Plug 2/7-pole, HAN7D, gasket
Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Nr 15 Order code 52020763
Plug 3-pole, M12, gasket
Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Order code 71111056
Housing filter VA,EPDM,F15/31/T14/17,1pc
Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Order code 71219639
Housing filter VA, VMQ, F15, T17, 1 pc.
Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
-
-
Nr 21 Order code 71206971
Sealing set FVQM, T14.5 pcs.
Consists of: 5x O-ring 75.87x2.62 FVMQ. Usage: housing T14, FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 20 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 52020433
Cover T14/T15 Alu, Ex d, gasket
Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71002810
Cover T17 316L, sight glass, gasket
Material: 316L. Sight glass: mineral glass. Flat gasket EPDM, centering ring, screw. For approval 2,3,4,7,8,Q,W. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval BC,BD,IB. Usage: FMD71/FMD72.
-
Nr 20 Order code 71002811
Cover T17 316L, sight glass PC, gasket
Material: 316L. Sight glass: Polycarbonate PC. Flat gasket EPDM, centering ring, screw. For approval A,E,F,H,I,R,S,U,1,6. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. For approval AA,BA,CA,CB,CC,CD,FA,FB, FD,IA. Usage: FMD71/FMD72.
-
Nr 20 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
Nr 20 Order code 71206968
Cover T14 316L, Ex d, sight glass, FVMQ
Material: 316L. Sight glass: mineral glass,coated. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245247
Cover T14/T15 Alu, sight glass, gasket
Material: aluminium, coated. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245249
Cover T14/T15 Alu,Exd,sight glass,gasket
Material: aluminium. Sight glass mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 20 Order code 71245250
Cover T14 316L, Ex d, sight glass, EPDM
Material: 316L. Sight glass: mineral glass, coated. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 25 Order code 52028310
Cover T14 316L, Ex d, EPDM
Material: 316L. O-ring EPDM, FDA. Individual tested, EEx d/XP. Usage: FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 71002774
Cover T17 316L, gasket
Material: 316L. Flat gasket EPDM, centering ring, screw. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 71206965
Cover T14 316L, Ex d, FVMQ
Material: 316L. O-ring FVMQ. Individual tested, EEx d/XP. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75.
-
-
-
Order code 71290825
Ground terminal T14/T15/T17, F30/F31
Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 25 Order code 52020432
Cover T14/T15 Alu, gasket
Material: aluminium, coated. O-ring EPDM, FDA. Not for EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 25 Order code 52020433
Cover T14/T15 Alu, Ex d, gasket
Material: aluminium, coated. O-ring EPDM, FDA. EEx d/XP. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 52024111
Electronics HART Ex, ext. p. b., v2.0
4-20mA, version 2.0. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 52024400
Electronics HART Ex, v2.0
4-20mA, version 2.0. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71026359
Electronics HART Ex, ext. p. b., v2.10
4-20mA, version 02.10.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71196093
Electronics HART Ex, ext. p. b., v2.11
4-20mA, version 2.11.zz. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71263933
Electronics HART Ex, v2.20
4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71263934
Electronics HART Ex, ext. p. b., v2.20
4-20mA. Software version 02.20.zz, HART 7, DevRev22. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71386147
Elektronics HART Ex, v2.30
4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on electronics. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
Nr 30 Order code 71386153
Electronics HART Ex, ext. p. b., v2.30
4-20mA. Software version 02.30.zz, HART 7, DevRev23. Push button on housing. Usage: FMB70, FMD77/FMD78, PMC71, PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
-
-
Order code 52026762
Upgrade electronics HART Ex, v2.1
Consists of: electronics HART Ex, version 2.1. Push button on electronics. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 71026358
Electronics HART Ex, v2.10
4-20mA, version 02.10.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 30 Order code 71196092
Electronic HART Ex, v2.11
4-20mA, version 02.11.zz. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for MID parts certificate (PMP71).
-
-
-
Order code 52026763
Upgrade electr. HART Ex,ext.push b.,v2.1
Consists of: electronics HART Ex, version 2.1. Push button external. Push button, housing HART version 2. Display housing. Usage: conversion electronics 1.0 > 2.1, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Order code 71071824
Electronics PA, HW02.00, SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Order code 71071825
Electronics PA, ext. p.b., HW02.00,SW4.0
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Order code 71071826
Electronics FF, HW2.00, SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on electronics. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 71071827
Electronics FF, ext. p.b., HW2.00,SW3.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 15mA +/- 1mA. Push button on housing. Verwendung: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Order code 71214057
Electronics PA, Ex, HW2.00, SW3.00
PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Order code 71214064
Electronics PA, ext. p.b.,HW2.00, SW3.00
PROFIBUS PA, Ex. Hardware version 02.00. Software version 03.00.zz. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 71214066
Electronics FF, ext. p.b.,HW2.00, SW2.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Order code 71214069
Electronics FF, HW2.00, SW2.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 02.00.zz. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 30 Order code 71214890
Electronics FF, ext. p.b.,HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
Nr 30 Order code 71214892
Electronics FF, HW2.00, SW4.00
FOUNDATION Fieldbus, Ex. Hardware version 02.00. Software version 04.00.zz, FF, DevRev07. Current consumption 15mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for SIL.
-
-
-
Order code 71224775
Electronics PA, HW02.00, SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on electronics. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Order code 71224776
Electronics PA, ext.p. b.,HW02.00,SW4.01
PROFIBUS PA, Ex. Hardware version 02.00. Software version 04.01.zz, PROFIBUS PA, Profile 3.02, DevRev03. Current consumption 13mA +/-1mA. Push button on housing. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 31 Order code 52027785
HistoROM / M-DAT, 16K
Setup-/diagnostic software included. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 35 Order code 52020434
Terminal 3-pole, RFI, HART, TIIS
RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75, TIIS Ex ia.
-
Nr 35 Order code 52026605
Terminal 2-pole, RFI, PA, TIIS
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75. TIIS Ex ia, TIIS Ex d. PMC71, TIIS Ex ia.
-
Nr 35 Order code 52027691
Terminal 2-pole, RFI, FF, Ex
RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028473
Terminal 3p., RFI, HART, OVP, TIIS
Overvoltage protection, RFI-filter. Usage: FMB70, FMD76/FMD77/FMD78, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028475
Terminal 2-pole, RFI, PA, OVP, Ex
Overvoltage protection, RFI-filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71028476
Terminal 2-pole, RFI, FF, OVP, Ex
Overvoltage protection, RFI-filter. FOUNDATION Fieldbus. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71121574
Terminal 2-pole, RFI, PA, Ex
RFI filter. PROFIBUS PA. Usage: FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Not for TIIS.
-
Nr 35 Order code 71191892
Terminal 3-pole,Li=0, RFI,HART,Ex ia/Exd
RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
Nr 35 Order code 71191894
Termin.3-p.,Li=0,RFI,HART,OVP,Ex ia/Exd
Overvoltage protection, RFI-filter. Not for TIIS Ex ia, TIIS Ex d. Usage: FMB70, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75.
-
-
-
Nr 40 Order code 71002865
Display module VU340, Cbar/Dbar/Dpilot S
Digital display, 3 push buttons, snapped bracket. Languages DE/EN/FR/ES/IT/NL, from software version 02.00.zz; Usage: electronics HART. Languages DE/EN/FR/ES/IT/NL/JA/ZH. From software version 02.01.zz; Electronics HART. Languages DE/EN/FR/ES/IT/JA/ZH/RU, from software version 02.11.zz; Electronics HART. From software version 04.00.zz; Electronics PROFIBUS PA. From software version 03.00.zz; Electronics FOUNDATION Fieldbus, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP72/PMP75. From software version 01.00.zz; Electronics HART, FMD71/FMD72.
-
-
-
Order code 71007843
ToF Adapter FXA291
Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.
-
Order code 52024609
Mounting set Deltabar S, 7/16-20UNF
Screws 7/16-20UNF, stainless steel. Material: 316L. Usage: wall/pipe mounting 2", FMD77/FMD78, PMD75.
-
Order code 943153-0031
-
Order code 71043886
Cable PE, L=2m/80inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043888
Cable PE, L=5m/200inch, separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71043889
Cable PE, L=10m/400inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71070738
Cable FEP, L=5m/200inch,separate housing
Connection cable sensor>sep. housing. Usage: FMB50/FMB51/FMB52, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Order code 71377370
Flushing ring NPS 2" Cl. 150-2500, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377371
Flushing ring NPS 3" Cl. 150-2500, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377380
Flushing ring DN50, PN16-400, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code 71377383
Flushing ring DN80, PN16-400, 316L
Consists of: 2x flushing ring connection. Thread ASME FNPT 1/2. Usage: FMB70, FMD71/FMD72/FMD77/FMD78, PMC71, PMP55, PMP71/75.
-
Order code XPRFID-
-
-
Sản phẩm cũ