Dust concentration: 0 ... 200 mg/m³ / 0 ... 10,000 mg/m³ The measurement depends on measuring distance and dust properties
Process temperature
–40 °C ... +600 °C
Process pressure
With MCU-P control unit: –50 hPa ... 2 hPa With external purge air unit: –50 hPa ... 30 hPa
Ambient temperature range
–40 °C ... +60 °C
Process gas humidity
Non-condensing
Degree of protection
IP66, IP54
Conformities
Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS 2010/75/EU U.S. EPA PS-1 compliant
With our broad range of solutions Endress+Hauser has proven applicability in the entire power generation process, from gas flow to combustion efficiency to emissions monitoring.
Emission Monitoring Solutions – broad instrument portfolio and
longstanding experience