Interface Unit IECEx: Zone 1: Ex db eb ia IIC T4 Gb Zone 1: Ex db ia IIC T4 Gb Zone 2: EX ec ia IIC T4 Gc
ATEX: Zone 1: II 2G Ex db eb ia IIC T4 Gb Zone 1: II 2G Ex db ia IIC T4 Gb Zone 2: II 3G Ex ec ia IIC T4 Gc
NEC/CEC (US/CA): Class I, Zone 1, AEx d ia IIC T4 Gb Class I, Division 1, Groups B, C, D, T4 Class I, Zone 2, AEx ec ia IIC T4 Gc Class I, Division 2, Group A, B, C and D, T4
Sensors F1F-S/P/R: IECEx: Zone 1: Ex db [ia Ga] IIC T6 Ga/Gb ATEX: Zone 1: II 1/2 G Ex db [ia Ga] IIC T6 Ga/Gb NEC/CEC (US/CA): Class I, Division 1, Groups B, C and D, T4; Class I, Zone 1, Ex/AEx d[ia] IIB + H2, T4;
F1F-M: IECEx: Zone 1: Ex db [ia Ga] IIB T4 Ga/Gb ATEX: Zone 1: II 1/2 G Ex db [ia Ga] IIB T4 Ga/Gb NEC/CEC (US/CA): Class I, Division 1, Groups C and D, T4; Class I, Zone 1, Ex/AEx d[ia] IIB, T4;
F1F-H: IECEx: Zone 1: Ex db IIC T6 Gb ATEX: Zone 1: II 2 G Ex db IIC T6 Gb NEC/CEC (US/CA): Class I, Division 1, Groups B, C and D, T4; Class I, Zone 1, Ex/AEx d IIB + H2, T4;
模拟输出
使用 I/O 模块(可选)时最多6个输出 16位:4 mA ... 20 mA;7 V DC ... 30 V DC 符合 NAMUR NE43,无源,电绝缘, 极性反接保护
数字输出端
开关量输出: 使用I/O 模块(可选)时最多6个输出,电隔离 最大电流: 70 mA 最大开关频率: 50 Hz 最大输入电压: 30 V DC 最大输出饱和电压: 0.5 V DC 可切换 Namur/集电极开路,极性反接保护 数字输出/频率输出: 使用 I/O 模块(可选)时最多12个数字输出端;电隔离 最大电流: 50 mA 最大开关频率: 10 kHz 最大输入电压: 30 V DC 最大输出饱和电压: 1.8 V DC 可切换 Namur/集电极开路,极性反接保护
Software for configuration and parameterization of Endress+Hauser SICK FLOWSIC gas meters. FLOWgate™ supports i-diagnostics™ for FLOWSIC gas meters.
语言:
Language neutral
版本:
26/03/2026
文件大小:
342 MB
文件名:
FLOWgate™
42文档
《操作手册》(BA)
FLOWgate™ – Software Manual
《操作手册》(BA)
英语版 - 03/2025
New version available in English
The FLOWgate™ software provides a user-friendly access to measurement data, configuration, and diagnostic of the flow meter. The software supports i-diagnostics™ features for FLOWSIC gas meters.
Supplement (to be used only in combination with the currently valid Operating Instructions) to: ● FLOWSIC100 Flare-XT when the F1F-R sender/receiver units are used with an Interface Unit, ● FLOWSIC100 Flare-XT Transmitter when the F1F-R sender/receiver units are used as stand-alone Transmitter.
Description of the stainless steel enclosure option which is available for the Interface Unit. With this additional option, the Interface Unit can safely be isolated from the corrosive offshore environment.
Endress+Hauser offers the best solutions through a huge range of products and systems to measure and perform even under the most rigorous operating conditions.