总氮是决定地表水水质和衡量废水排放影响的一个关键指标。总氮包括了水中的有机氮与无机氮。如果地表水中的总氮氮浓度上升则意味着地表水可能受到了管网污水、垃圾渗滤液或者农业面源污染的影响。 Liquiline System CA80TN总氮分析仪在线进行高精度总氮测量,为过程安全保驾护航。分析仪配备高级诊断功能,支持远程访问,归档记录可作为证明文件直接提交给权威机构。
The monitoring solution provides the Visp fish farm with stable, reliable oxygen control, enabling optimal conditions for fish and reducing effort and risk.
Proline Teqwave MW 300 delivers stable real-time data taken directly from the process, reduces maintenance work, and allows quicker intervention if changes to the process are required.
Kerry DCF produces spreads and butter products for the retail market. The company wanted to automate its test for chemical oxygen demand in its treated effluent to save time and optimise the process.
Memosens CPS11E ensures precise pH monitoring in biodiesel production, improving product quality, process stability and sensor lifetime under harsh conditions.
Process analyzer for total nitrogen in aqueous solutions UV photometric method following HJ636-2012
尺寸
Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
设计
Open design, cabinet and stand housing High-Performance plastic ASA-PC, additional stand coated steel
过程温度
4 to 40 °C (39.2 to 104 °F)
环境温度
5 to 40 °C (41 to 104 °F)
过程压力
At atmospheric pressure, < 0.2 bar
探头处的流速
Min. 15 ml/min (0.51 fl.oz/min)
探头的一致性
Aqueous, homogeneous
应用
Monitoring of wastewater treatment plant outlet Monitoring of the surface water quality Monitoring of industrial water treatment Monitoring and optimization of industrial wastewater treatment plants
电源
100 to 120 VAC / 200 to 240 VAC ± 10% 50 ± 1 or 60 ± 1,2 Hz
输出
2x 0/4 to 20 mA Modbus RS485/TCP (optional) Webserver (optional) Ethernet/IP Profibus DP Alarm relay
输入
1 measuring channel 1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)
测量范围
0 to 20 mg/l N 0 to 50 mg/l N 0 to 250 mg/l N
耗材
Reagents and standard solutions CY80TN as well as cleaner CY800 are necessary for the operation Regular maintenance is done with the parts of the maintenance kit CAV880
Ensure optimal CA80 analyzer performance with expert commissioning and first year preventive maintenance service for seamless operation and reduced downtime